BS 5724-2.16(1989) : 1989
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR HAEMODIALYSIS EQUIPMENT
Hardcopy , PDF
07-15-1998
English
01-01-1989
National foreword
Committees responsible
Introduction
Section one: General
1. Scope and object
2. Terminology and definitions
6. Identification, marking and documents
Section two: Safety requirements
12. Single fault condition
Section three: Protection against electric shock hazards
19. Continuous leakage currents and patient auxiliary
currents
20. Dielectric strength
Section four: Protection against mechanical hazards
Section five: Protection against hazards from unwanted
or excessive radiation
Section six: Protection against the hazards of explosions
in medically used rooms
Section seven: Protection against excessive temperatures,
fire and other hazards, such as human errors
44. Overflow, spillage, leakage, humidity, ingress of
liquids, cleaning, sterilization and disinfection
45. Pressure vessels and parts subject to pressure
46. Human errors
49. Interruption of the POWER SUPPLY
Section eight: Accuracy of operating data and protection
against incorrect output
50. Accuracy of operating data
51. Protection against incorrect output
Section nine: Fault conditions causing overheating and/
or functional damage; environmental tests
Section ten: Constructional requirements
56. Components and general assembly
57. MAINS PARTS, components and layout
Appendix AA. Rationale for the particular requirements
of this standard
Sets out safety requirements for single PATIENT single pass HAEMODIALYSIS EQUIPMENT for use either by medical staff or under the supervision of medical expertise, including patient operated HAEMODIALYSIS EQUIPMENT. Excludes blood lines, HAEMODIALYSERS, DIALYSING FLUID CONCENTRATE and water purification EQUIPMENT. Includes sections on protection against electric shock, mechanical hazards, excess radiation, explosions in medically used rooms, excess temperatures, fire, etc., accuracy of operating data and protection against incorrect output, fault conditions and constructional requirements.
Committee |
HCC/23
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
IEC TR 60513:1994 | Fundamental aspects of safety standards for medical electrical equipment |
BS 3930-1(1987) : AMD 8072 | CONICAL FITTINGS WITH A 6% (LUER) TAPER FOR SYRINGES, NEEDLES AND OTHER MEDICAL EQUIPMENT - SPECIFICATION FOR GENERAL REQUIREMENTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.