55.1 Scope
55.2 General test requirements
55.3 Definitions
55.4 Classification of luminaires
55.5 Marking
55.6 Construction
55.7 Creepage distances and clearances
55.8 Provisions for earthing
55.9 Terminals
55.10 External and internal wiring
55.11 Protection against electric shock
55.12 Endurance test and thermal tests
55.13 Resistance to ingress of dust and moisture
55.14 Insulation resistance and electric strength
55.15 Resistance to heat, fire and tracking
55.16 Radio interference suppression
55.17 Photometric characteristics
Figures
1. Arrangement for impact test for hand-held inspection
luminaires
2. Apparatus for flexing test for hand-held inspection
luminaires
3. Crush test apparatus for hand-held inspection
luminaires
4. Apparatus for testing durability of external markings
on hand-held inspection luminaires
Appendix
A. Test for indelibility of external markings on hand-
held inspection luminaires
Electrical and mechanical safety of luminaires used to illuminate wards, operating theatres and treatment rooms and also hand-held and fixed luminaires for examination purposes.
Committee |
CPL/34/4
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
BS 4533-103.2:1986 | Luminaires. Performance requirements Specification for photometric characteristics of luminaires for hospitals and health care buildings |
BS 4533-102.8(1982) : LATEST | LUMINAIRES - PARTICULAR REQUIREMENTS - SPECIFICATION FOR HANDLAMPS |
BS 4533-101:1981 | Luminaires Specification for general requirements and tests |
BS 4533-103.2:1986 | Luminaires. Performance requirements Specification for photometric characteristics of luminaires for hospitals and health care buildings |
BS 5724-1:1979 | Medical electrical equipment Specification for general safety requirements |
BS 4533-102.6(1981) : LATEST | LUMINAIRES - PARTICULAR REQUIREMENTS - SPECIFICATION FOR LUMINAIRES WITH BUILT IN TRANSFORMERS FOR FILAMENT LAMPS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.