• There are no items in your cart

BS 3941:1975

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Specification for voltage transformers

Available format(s)

Hardcopy , PDF

Superseded date

09-16-2004

Language(s)

English

Published date

08-29-1975

US$257.86
Excluding Tax where applicable

Co-operating organizations
Foreword
Specification
Section one. General
1 Scope
2 References
3 Definitions
4 Service conditions
Section two. Requirements for all voltage transformers
5 Rated frequency
6 Rated secondary voltages
7 Rated outputs
8 Rated transformation ratios
9 Rated voltage factors
10 Characteristics of voltage transformers with
    residual voltage windings
11 Limits of temperature rise
12 Rated insulation levels
13 Creepage distances
14 Accuracy class designations
15 Limits of error
16 Marking
17 Test requirements
18 Tests
Section three. Additional requirements for capacitor
               voltage transformers
19 General requirements
20 Additional performance requirements
21 Test requirements
22 Marking
Section four. Requirements for capacitors for use with
               capacitor voltage transformers
23 General requirements
24 Test requirements
25 Tests
26 Insulation level
27 Marking
Appendices
A Service conditions
B Guidance on the application of measuring voltage
    transformers
C Rating of voltage transformers at frequencies other
    than rated frequency
D Temperature measurements
E Guidance for installation and operation of
    capacitors
F Information required by the manufacturer
Tables
1 Rated transformation ratios
2 Standard values of rated voltage factors
3 Characteristic of voltage transformers with residual
    voltage windings
4 Limits of temperature rise of windings
5a Insulation test levels for rated highest equipment
    voltages up to and including 72.5 kV
5b Insulation test levels for rated highest equipment
    voltages of 100 kV and above
6 Limits of voltage error and phase displacement for
    measuring voltage transformers
7 Limits of voltage error and phase displacement for
    protective voltage transformers
8 High voltage winding terminal to be earthed during
    impulse voltage tests
9 Applied power frequency test voltages on primary
    windings (after erection on site)
10 Applied power frequency test high voltage tests for
    durations exceeding one minute (after erection on
    site)
11 Selection of class of accuracy of measuring voltage
    transformers
Figures
1 Single-phase voltage transformer having one or two
    secondary windings without tappings
2 Single-phase voltage transformer having one or two
    secondary windings with tappings
3 Single-phase or 3-phase voltage transformer with one
    residual voltage winding
4 3-phase voltage transformer with one or two
    secondary windings without tappings
5 3-phase voltage transformer with one secondary
    winding with tappings
6 Circuit for accuracy test on a transformer having a
    rated voltage factor of 1.5
7 Circuit for accuracy test on a transformer having a
    rated voltage factor of 1.9
8 Circuit for accuracy test on the residual voltage
    winding of a transformer having a rated voltage
    factor not exceeding 1.5
9 Circuit for accuracy test on the residual voltage
    winding of a transformer having a rated voltage
    factor of 1.9
10 Alternative circuit for accuracy test on the
    residual voltage winding of a transformer having a
    rated voltage factor of 1.9
11 Diagrammatic arrangement of capacitor voltage
    transformer

Performance and test requirements for electromagnetic and capacitor voltage transformers for use with measuring instruments and protective equipment. Requirements for capacitor dividers for use with capacitor voltage transformers. Guidance on application.

Committee
PEL/38
DocumentType
Standard
Pages
40
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 60186:1987 Similar to
UNE-EN 538:1995 Identical
UNE-EN 60523:1996 Identical

DEFSTAN 02-530/2(2004) : 2004 REQUIREMENTS FOR MAIN AND DISTRIBUTION SWITCHGEAR - CATEGORY 2
BS 7354:1990 Code of practice for design of high-voltage open-terminal stations
BS 5704:1979 Method for specifying the performance of digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital convertors
BS 5986:1980 Specification for electrical safety and performance of gas fired space heating appliances with inputs 60 kW to 2 MW
DEFSTAN 02-604/2(2004) : 2004 ELECTRICAL INDICATING INSTRUMENTS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.