Assessment of departures from roundness Specification for characteristics of stylus instruments for measuring variations in radius (including guidance on use and calibration)
Hardcopy , PDF
English
12-31-1982
Cooperating organizations
Foreword
1 Scope
2 Definitions
3 Instruments
Appendix A - Departure from roundness of
the measured profile of the workpiece
Appendix B - Use of the instrument
Appendix C - Calibration
Appendix D - Determination of systemmatic errors
of rotation
Appendix E - Determination of least squares centre
and circle
Appendix F - Rules for plotting and reading polar
graphs
Publication referred to
Characteristics of contact (stylus) instruments based on the method of determining departures from roundness by measuring variations in radius. Appendices deal with departure from roundness of the measured profile, use of instrument, calibration, determination of systematic errors, least square centre and circle plotting and reading polar graphs.
Committee |
TPR/1
|
DevelopmentNote |
Supersedes 81/73683 DC. (07/2005) Together with BS 3730-1(1982) and BS 3730-3(1982), it supersedes BS 3730(1964). (08/2009)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This Part of this British Standard specifies the characteristics of contact (stylus) instruments based on the method of determining departures from roundness by measuring variations in radius.
It relates to the assessment of the departures from ideal roundness of a workpiece through the medium of a profile transformation, obtained under reference conditions, expressed with respect to any one of the following centres:
- centre of the least squares circle;
- centre of the minimum zone circle;
- centre of the minimum circumscribed circle;
- centre of the maximum inscribed circle;
NOTE 1 Each of the foregoing centres may have its field of application. The position of the least squares centre can be calculated from a simple explicit formula given in Appendix E.
Departures of roundness from the measured profile, use of instrument, calibration and determination of systematic errors of rotation are dealt with in Appendix A to Appendix D, respectively. Appendix F gives rules for plotting and reading polar graphs.
NOTE 2 Reference conditions include the stylus, frequency limitations of an electric wave filter (if used), permissible eccentricity of the graphic or digital representation of the profile (generally 1/7 to 1/15 of its mean radius, see Appendix F) and the position of the measured section or sections relative to some feature of the workpiece.
NOTE 3 The titles of the publications referred to in this standard are listed on the inside back cover.
Standards | Relationship |
UNE-EN ISO 18254-2:2020 | Identical |
BS 7825-2:1996 | Calibration of rubber and plastics test equipment Calibration procedures |
BS 3531-13:1983 | Surgical implants Specification for bearing surfaces of hip joint prostheses |
DEFSTAN 47-22/1(1979) : 1979 | END FITTINGS FOR FLEXIBLE HOSE ASSEMBLIES FOR AIRCRAFT - METRIC |
BS 3730-3:1982 | Assessment of departures from roundness Methods for determining departures from roundness using two- and three-point measurement |
BS 308-3:1990 | Engineering drawing practice Recommendations for geometrical tolerancing |
SAEITC TSC47-022_01 | END FITTINGS FOR HOSE ASSEMBLIES METRIC |
VDI/VDE 2631 Blatt 1:2016-08 | Form measurement - Principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.