BS 1790:1961
Current
The latest, up-to-date edition.
Specification for length bars and their accessories (imperial units)
Hardcopy , PDF
English
01-31-1961
Cooperating organizations
Foreword
Specification
1. Scope
2. Nomenclature and definitions
Section one: Length bars
3. General design
4. Material
5. Hardening and stabilizing
6. Finish
7. Accuracy
8. Connecting screws for inspection and workshop bars
9. Marking
10. Case
11. Protection against climatic conditions
Section two: Accessories for use with inspection and
workshop length bars
12. Material
13. Method of attachment
14. Base
15. Large radiused jaw
16. Small plane-faced jaw
17. Spherical end piece
18. Screws
19. Case
20. Protection against climatic conditions
Appendices
A. Recommended sets of inspection and workshop grades
of length bars
B. Details of published papers on screwed connections
Length gauges of cylindrical bar type in four grades of accuracy; reference, calibration, inspection, workshop. Accuracy for sizes up to 48 in and metric sizes up to 1200 mm in all grades; two types of screwed connection, one a refined type developed by NPL for inspection bars. Design and accuracy for accessories used with workshop bars. Sets of inspection and workshop bars.
Committee |
TPR/1
|
DevelopmentNote |
Inactive for new designs. (10/2005)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This British Standard relates to length bars of the cylindrical type, in inch sizes up to 48 in, having parallel end faces finished by lapping.
If longer bars are required, they shall be uniform in diameter and straight overall to the limits laid down in Clauses 7 a) and b); tolerances for flatness and parallelism of faces shall be proportionate to those specified in the appropriate Table 1, Table 3, Table 5 and Table 7, and their lengths shall conform to the requirements of Clause 7 d) ii) .
Provision is made for two designs of length bar, one with complete plane faces and the other with annular faces surrounding an internally threaded hole at one end or both ends of the bar.
Section 1 provides for four grades of accuracy, namely:
- Reference
- Calibration
- Inspection
- Workshop.
Reference grades bars, as their name implies, are intended for use as reference standards. They have completely plane faces and embody the highest order of accuracy as regards both their end faces and the finishing of their actual lengths to their nominal sizes.
It is recommended that they should be supplied with a certificate by the National Physical Laboratory which confirms their full accordance with this British Standard and gives the deviations from their nominal lengths to an appropriately high order of accuracy.
To derive the maximum benefit from these very high grade reference bars they should be used only in standards rooms which are temperature controlled at 68 ± 1 °F (20 ± ½ °C) and with comparators of suitably high sensitivity.
Calibration grade bars possess the same degree of perfection in their completely plane end faces as the reference grade bars . They differ only in the somewhat wider tolerances allowed in the adjustment of their lengths to the nominal sizes, which thus permits them to be produced more economically than reference grade bars. It is recommended, however, that calibration grade bars should, like those of reference grade, be supplied and used with a N.P.L. certificate giving the actual deviation in the length of each bar from its nominal size.
NOTE The wider tolerances permitted on the lengths of calibration grade bars render them no less service able than reference grade bars when used as standards for the accurate measurement of other bars.
As already mentioned for reference grade bars, calibration grade bars require to be used under suitable conditions of temperature and with appropriate comparators if the fullest advantage is to be gained of the very high accuracy associated with their certified sizes.
Inspection grade bars have internally threaded ends and can thus be used in combination with each other. They are intended for use in inspection rooms and tool rooms.
Workshop grade bars also have internally threaded ends and can be used with slip gauges, comparators and their own accessories for measuring gauges, jigs, work pieces, etc . As their name implies, they are intended for use in workshops.
General dimensions, tolerances on length and standards of accuracy for flatness, parallelism and squareness of faces are specified for all grades of bars.
Section 2 relates to the essential features of design and accuracy of accessories for use with inspection and workshop grade bars.
Recommended sets of inspection and workshop grade bars and the sources of papers on the refined type of screwed connection are given in Appendices.
Standards | Relationship |
UNE-EN 15528:2022 | Identical |
BS 5317:1976 | Specification. Metric length bars and their accessories |
BS 1685:1951 | Specification for bevel protractors (mechanical and optical) |
BS 959:1950 | Specification for internal micrometers (including stick micrometers) |
BS 959:2008 | Specification for internal micrometers (including stick micrometers) |
08/30177716 DC : DRAFT JUNE 2008 | BS 959 - SPECIFICATION FOR INTERNAL MICROMETERS (INCLUDING STICK MICROMETERS) |
BS 870:1950 | Specification for external micrometers |
BS 6808-1:1987 | Coordinate measuring machines Glossary of terms |
BS 1734:1951 | Specification for micrometer heads |
BS 1133-6(1966) : 1966 | PACKAGING CODE - TEMPORARY PROTECTION OF METAL SURFACES AGAINST CORROSION (DURING TRANSPORT AND STORAGE) |
BS 888:1950 | Specification for slip (or block) gauges and their accessories |
BS 84:1956 | Specification for parallel screw threads of Whitworth form |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.