BIS IS 10322-1 : 2014
Current
The latest, up-to-date edition.
LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
01-12-2013
FOREWORD
SECTION 0 - GENERAL INTRODUCTION
SECTION 1 - TERMINOLOGY
SECTION 2 - CLASSIFICATION OF LUMINAIRES
SECTION 3 - MARKING
SECTION 4 - CONSTRUCTION
SECTION 5 - EXTERNAL AND INTERNAL WIRING
Section 6 - Not used
SECTION 7 - PROVISION FOR EARTHING
SECTION 8 - PROTECTION AGAINST ELECTRIC SHOCK
SECTION 9 - RESISTANCE TO DUST, SOLID OBJECTS
AND MOISTURE
SECTION 10 - INSULATION RESISTANCE AND ELECTRIC
STRENGTH
SECTION 11 - CREEPAGE DISTANCES AND CLEARANCES
SECTION 12 - ENDURANCE TEST AND THERMAL TEST
SECTION 13 - RESISTANCE TO HEAT, FIRE AND TRACKING
SECTION 14 - SCREW TERMINALS
SECTION 15 - SCREWLESS TERMINALS AND ELECTRICAL
CONNECTIONS
ANNEX A - TEST TO ESTABLISH WHETHER A CONDUCTIVE
PART MAY CAUSE AN ELECTRIC SHOCK
ANNEX B - TEST LAMPS
ANNEX C - ABNORMAL CIRCUIT CONDITIONS
ANNEX D - DRAUGHT-PROOF ENCLOSURE
ANNEX E - DETERMINATION OF WINDING TEMPERATURE
RISES BY THE INCREASE-IN-RESISTANCE METHOD
ANNEX F - TEST FOR RESISTANCE TO STRESS CORROSION
OF COPPER AND COPPER ALLOYS
ANNEX G - Void
ANNEX H - Void
ANNEX J - EXPLANATION OF IP NUMBERS FOR DEGREES
OF PROTECTION
ANNEX K - TEMPERATURE MEASUREMENT
ANNEX L - GUIDE TO GOOD PRACTICE IN LUMINAIRE DESIGN
ANNEX M - CONVERSATION GUIDE TO TABLE 11.1 -
DETERMINATION OF CREEPAGE DISTANCES AND
CLEARANCES
ANNEX N - EXPLANATION OF LUMINAIRES [Luminaire
suitable for direct mounting on normally
flammable surfaces] MARKING
ANNEX P - REQUIREMENTS FOR THE PROTECTIVE SHIELD
TO BE FITTED TO LUMINAIRES USING METAL
HANDLE LAMPS FOR PROTECTIVE MEASURES
AGAINST UV RADIATION
ANNEX Q - CONFORMITY TESTING DURING MANUFACTURE
ANNEX R - SCHEDULE OF AMENDED CLAUSES CONTAINING
MORE SERIOUS/CRITICAL REQUIREMENTS WHICH
REQUIRE PRODUCTS TO BE RETESTED
ANNEX S - REQUIREMENTS FOR THE IDENTIFICATION OF
A FAMILY OR RANGE OF LUMINAIRES FOR TYPE
TESTING
Defines general requirements for luminaires, incorporating electric light source for operation from supply voltages up to 1100 V.
Committee |
ETD 24
|
DocumentType |
Standard
|
PublisherName |
Bureau of Indian Standards
|
Status |
Current
|
BIS SP 72 : 2010(R2014) | NATIONAL LIGHTING CODE 2010 |
BIS IS 10322-5-5 : 2013 | LUMINAIRES - PART 5: PARTICULAR REQUIREMENTS - SECTION 5: FLOODLIGHTS |
BIS IS 15967-1 : 2013 | CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - PART 1: SAFETY REQUIREMENTS |
BIS IS/IEC 60079-15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION 'N' ELECTRICAL APPARATUS |
BIS IS 15974 : 2013 | AUXILIARIES FOR LAMPS STARTING DEVICES (OTHER THAN GLOW STARTERS) - PERFORMANCE REQUIREMENTS |
BIS IS 10322-5-6 : 2013 | LUMINAIRES - PART 5: PARTICULAR REQUIREMENTS - SECTION 6: HANDLAMPS |
BIS IS 1258 : 2005(R2015) | BAYONET LAMP HOLDERS |
BIS IS 302-1 : 2008 AMD 3 2014 | SAFETY OF HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - PART 1: GENERAL REQUIREMENTS |
BIS IS 10322-5-8 : 2013 | LUMINAIRES - PART 5: PARTICULAR REQUIREMENTS - SECTION 8: EMERGENCY LIGHTING |
BIS IS 9968-1 : 1988 AMD 3 2016 | SPECIFICATION FOR ELASTOMER INSULATED CABLES - PART 1: FOR WORKING VOLTAGES UPTO AND INCLUDING 1100 VOLTS |
BIS IS 12063 : 1987(R2004) | CLASSIFICATION OF DEGREES OF PROTECTION PROVIDED BY ENCLOSURES OF ELECTRICAL EQUIPMENT |
BIS IS 616 : 2017 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS |
BIS IS 9974-1 : 1981 AMD 4 | HIGH PRESSURE SODIUM VAPOUR LAMPS - PART 1: GENERAL REQUIREMENTS AND TESTS |
BIS IS 1271 : 2012 | ELECTRICAL INSULATION - THERMAL EVALUATION AND DESIGNATION |
ISO 75:1987 | Plastics and ebonite Determination of temperature of deflection under load |
BIS IS 1401 : 2008 | PROTECTION OF PERSONS AND EQUIPMENT BY ENCLOSURES - PROBES FOR VERIFICATION |
BIS SP 30 : 2011(R2016) | NATIONAL ELECTRICAL CODE |
BIS IS 9000-7-1 TO 5 : 1979(R2004) | BASIC ENVIRONMENTAL TESTING PROCEDURES FOR ELECTRONIC AND ELECTRICAL ITEMS - PART 7: IMPACT TEST |
BIS IS 3010-1 : 1965(R2004) | APPLIANCE-CONNECTORS AND APPLIANCE-INLETS (NON-REVERSIBLE THREE-PIN TYPE) - PART 1: APPLIANCE CONNECTORS |
BIS IS 9974-2 : 1981(R2002) | HIGH PRESSURE SODIUM VAPOUR LAMPS - PART 2: STANDARD LAMP DATA SHEETS |
BIS IS 1258 : 2005(R2015) | BAYONET LAMP HOLDERS |
BIS IS 6616 : 1982(R2001) | BALLASTS FOR HIGH PRESSURE MERCURY VAPOUR LAMPS |
BIS IS 15687-1 : 2006 | SINGLE-CAPPED FLUORESCENT LAMPS - PART 1: SAFETY REQUIREMENTS |
BIS IS 3323 : 1980(R2002) | BI-PIN LAMP HOLDERS FOR TUBULAR FLUORESCENT LAMPS |
BIS IS 1293 : 2005 AMD 6 2013 | PLUGS AND SOCKET-OUTLETS OF RATED VOLTAGE UP TO AND INCLUDING 250 VOLTS AND RATED CURRENT UP TO 16 AMPERES - SPECIFICATION |
IEC 61031:1990 | Design, location and application criteria for installed area gamma radiation dose rate monitoring equipment for use in nuclear power plants during normal operation and anticipated operational occurrences |
BIS IS 11000-2-2 : 2008(R2015) | FIRE HAZARD TESTING - PART 2: TEST METHODS - SECTION 2: NEEDLE-FLAME TEST METHOD - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE |
BIS IS 10322-5-4 : 1987(R2015) | LUMINAIRES - PART 5: PARTICULAR REQUIREMENTS - SECTION 4: PORTABLE GENERAL PURPOSE LUMINAIRES |
BIS IS 694 : 2010(R2015) | POLYVINYL CHLORIDE INSULATED UNSHEATHED AND SHEATHED CABLES/CORDS WITH RIGID AND FLEXIBLE CONDUCTOR FOR RATED VOLTAGES UP TO AND INCLUDING 1100 V |
BIS IS 3010-2 : 1965(R2004) | APPLIANCE-CONNECTORS AND APPLIANCE-INLETS (NON-REVERSIBLE THREE-PIN TYPE) - PART 2: APPLIANCE INLET |
BIS IS 1416 : 1972(R2001) | SAFETY TRANSFORMERS |
BIS IS 10276-2 : 1982(R2003) | EDISON SCREW LAMPHOLDERS - PART 2: STANDARD DATA SHEETS FOR LAMP HOLDERS AND GAUGES |
BIS IS 15382-3 : 2006 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 3: USE OF COATING POTTING OR MOULDING FOR PROTECTION AGAINST POLLUTION |
BIS IS 15382-1 : 2014 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
BIS IS 12948 : 1990(R2001) | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) |
BIS IS 2824 : 2007 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
BIS IS 2215 : 2006(R2015) | STARTERS FOR FLUORESCENT LAMPS |
BIS IS 5921-1 : 1993(R2002) | METAL-CLAD BASE MATERIALS FOR PRINTED CIRCUITS FOR USE IN ELECTRONIC AND TELECOMMUNICATION EQUIPMENT - PART 1: GENERAL REQUIREMENTS AND TEST |
BIS IS 15518-1 : 2004 AMD 1 | SAFETY REQUIREMENTS FOR INCANDESCENT LAMPS - PART 1: TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES |
BIS IS 11000-2-1 : 2008(R2015) | FIRE HAZARD TESTING - PART 2: TEST METHODS - SECTION 1: GLOW-WIRE APPARATUS AND COMMON TEST PROCEDURE |
BIS IS QC 302400 : 1994(R2009) | FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT SECTIONAL SPECIFICATION FOR FIXED CAPACITORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION AND CONNECTION TO THE SUPPLY MAINS |
BIS IS 8913 : 1978(R2002) | METHODS OF MEASUREMENT OF LAMP CAP TEMPERATURE RISE |