ASTM F 604 : 1994
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Specification for Silicone Elastomers Used in Medical Applications (Withdrawn 2001)
Hardcopy , PDF
12-31-2001
English
01-01-1994
CONTAINED IN VOL 13.01 , 2000 Outlines features of cured or vulcanized silicone elastomeric materials obtained by the use of many fillers, specific polymers, and crosslinking systems.
Committee |
F 04
|
DocumentType |
Standard
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
1.1 This specification covers silicone elastomers intended for use as materials of construction for fabrication of medical devices.
1.2 Variations in ingredients, processing, and vulcanization (crosslinking/cure) systems of silicone elastomer are necessary to achieve the properties required in specific medical device applications.
1.2.1 An alphabetical/numerical code abbreviation is defined in this specification as what may be used to specify ingredients, crosslinking systems, processing conditions, and physical properties of many silicone elastomers used in medical device applications by a standard, abbreviated designation.
1.3 In all cases where the provisions of this specification are in conflict with those of the detailed specifications for a particular product, the latter shall take precedence.
1.3.1 When silicone elastomers are used in medical device applications where the materials requirements cannot be completely achieved by the technology prescribed in this specification, it may be necessary to adjust ingredients, processing, or cure systems to a greater extent to obtain the properties needed in these specific medical device applications.
1.3.1.1 When silicone elastomers are adjusted more extensively than prescribed in this specification, such adjustments shall be completely described and controlled in specifications for each specific material.
1.3.1.2 All sections of this specification that contain requirements pertinent to safety and effectiveness apply to all silicone elastomers used as materials of construction for medical devices, including those adjusted more broadly than defined in this specification.
1.4 While silicone elastomers have demonstrated excellent biocompatibility in medical device applications, the biocompatibility of silicone elastomers as a generic class has not been established. Many compositions and formulations are possible. Manufacturing practices, facilities, controls, process validation, and other considerations that ensure batch-to-batch duplication, assurance of identity, and quality of ingredients, as well as freedom from contamination or cross-contamination may vary widely within the silicone elastomer industry. Medical device manufacturers must ensure safety and effectiveness of each specific composition or formulation from each supplier in its intended applications. Historic, clinical, and biocompatibility data are pertinent prospectively only when all compounding, formulating, and fabrication are done in accordance with the provisions of Good Manufacturing Practice Regulations, which help ensure medical materials and devices are reasonably duplicated each time they are manufactured.
1.5 This specification is intended to assist in the development of specifications for formulated silicone elastomer compounds. It is also recommended for use in materials and finished device labeling to specify the type or types of silicone elastomers contained.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 1027 : 1986 : R2007 | Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices |
ASTM F 647 : 1994 : R2000 | Standard Practice for Evaluating and Specifying Implantable Shunt Assemblies for Neurosurgical Application |
ASTM F 1027 : 1986 : R2017 | Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices (Withdrawn 2023) |
AAMI NS28 : 1988 : R2015 | INTRACRANIAL PRESSURE MONITORING DEVICES |
ASTM F 881 : 1994 : R2000 | Standard Specification for Silicone Elastomer Facial Implants |
ASTM F 982 : 1986 : R2002 | Standard Specification for Disclosure of Characteristics of Surgically Implanted Clamps for Carotid Occlusion |
ASTM F 647 : 1994 : R2006 | Standard Practice for Evaluating and Specifying Implantable Shunt Assemblies for Neurosurgical Application |
ASTM F 2051 : 2000 : R2014 | Standard Specification for Implantable Saline Filled Breast Prosthesis |
BS EN 12010:1998 | Non-active surgical implants. Joint replacement implants. Particular requirements |
I.S. EN 12010:1998 | NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS |
AAMI NS28 : 1988 : R2010 | INTRACRANIAL PRESSURE MONITORING DEVICES |
DIN EN ISO 21534:2009-08 | NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS |
BS EN ISO 21534:2009 | Non-active surgical implants. Joint replacement implants. Particular requirements |
ASTM F 647 : 1994 : R2014 | Standard Practice for Evaluating and Specifying Implantable Shunt Assemblies for Neurosurgical Application |
ASTM F 1027 : 1986 : R2002 | Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices |
UNI EN ISO 21534 : 2009 | NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS |
AAMI NS28 : 1988 : R2006 | INTRACRANIAL PRESSURE MONITORING DEVICES |
ASTM F 1027 : 1986 : R1995 : EDT 1 | Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices |
ASTM F 982 : 1986 : R1998 | Standard Specification for Disclosure of Characteristics of Surgically Implanted Clamps for Carotid Occlusion |
I.S. EN ISO 21534:2009 | NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS |
ASTM F 982 : 1986 : R2008 | Standard Specification for Disclosure of Characteristics of Surgically Implanted Clamps for Carotid Occlusion (Withdrawn 2017) |
ASTM F 2051 : 2000 | Standard Specification for Implantable Saline Filled Breast Prosthesis |
ISO 21534:2007 | Non-active surgical implants Joint replacement implants Particular requirements |
ASTM F 881 : 1994 : R2006 | Standard Specification for Silicone Elastomer Facial Implants |
ASTM F 1027 : 1986 : R2012 | Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices |
DIN EN ISO 14607:2009-08 | NON-ACTIVE SURGICAL IMPLANTS - MAMMARY IMPLANTS - PARTICULAR REQUIREMENTS |
ASTM F 881 : 1994 : R2014 | Standard Specification for Silicone Elastomer Facial Implants |
ASTM F 2051 : 2000 : R2006 | Standard Specification for Implantable Saline Filled Breast Prosthesis |
EN 12010 : 1998 | NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS |
EN ISO 21534:2009 | Non-active surgical implants - Joint replacement implants - Particular requirements (ISO 21534:2007) |
ASTM D 926 : 2017 : REDLINE | Standard Test Method for Rubber Property—Plasticity and Recovery (Parallel Plate Method) |
ASTM D 1349 : 2014 : REDLINE | Standard Practice for Rubber—Standard Conditions for Testing |
ASTM D 792 : 2013 : REDLINE | Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement |
ASTM F 619 : 2014 : REDLINE | Standard Practice for Extraction of Medical Plastics |
ASTM D 865 : 2011 | Standard Test Method for Rubber<char: emdash>Deterioration by Heating in Air (Test Tube Enclosure) |
ASTM F 748 : 2016 : REDLINE | Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices |
ASTM D 3137 : 1981 : R2018 | Standard Test Method for Rubber Property—Hydrolytic Stability |
ASTM D 257 : 2014 : REDLINE | Standard Test Methods for DC Resistance or Conductance of Insulating Materials |
ASTM D 1566 : 2015 : REDLINE | TERMINOLOGY RELATING TO RUBBER |
ASTM D 570 : 1998 : R2018 | Standard Test Method for Water Absorption of Plastics |
ASTM D 1418 : 2017 : REDLINE | Standard Practice for Rubber and Rubber Latices—Nomenclature |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.