• Shopping Cart
    There are no items in your cart

ASTM F 604 : 1994

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Specification for Silicone Elastomers Used in Medical Applications (Withdrawn 2001)

Available format(s)

Hardcopy , PDF

Withdrawn date

12-31-2001

Language(s)

English

Published date

01-01-1994

US$75.00
Excluding Tax where applicable

CONTAINED IN VOL 13.01 , 2000 Outlines features of cured or vulcanized silicone elastomeric materials obtained by the use of many fillers, specific polymers, and crosslinking systems.

Committee
F 04
DocumentType
Standard
Pages
5
PublisherName
American Society for Testing and Materials
Status
Withdrawn

1.1 This specification covers silicone elastomers intended for use as materials of construction for fabrication of medical devices.

1.2 Variations in ingredients, processing, and vulcanization (crosslinking/cure) systems of silicone elastomer are necessary to achieve the properties required in specific medical device applications.

1.2.1 An alphabetical/numerical code abbreviation is defined in this specification as what may be used to specify ingredients, crosslinking systems, processing conditions, and physical properties of many silicone elastomers used in medical device applications by a standard, abbreviated designation.

1.3 In all cases where the provisions of this specification are in conflict with those of the detailed specifications for a particular product, the latter shall take precedence.

1.3.1 When silicone elastomers are used in medical device applications where the materials requirements cannot be completely achieved by the technology prescribed in this specification, it may be necessary to adjust ingredients, processing, or cure systems to a greater extent to obtain the properties needed in these specific medical device applications.

1.3.1.1 When silicone elastomers are adjusted more extensively than prescribed in this specification, such adjustments shall be completely described and controlled in specifications for each specific material.

1.3.1.2 All sections of this specification that contain requirements pertinent to safety and effectiveness apply to all silicone elastomers used as materials of construction for medical devices, including those adjusted more broadly than defined in this specification.

1.4 While silicone elastomers have demonstrated excellent biocompatibility in medical device applications, the biocompatibility of silicone elastomers as a generic class has not been established. Many compositions and formulations are possible. Manufacturing practices, facilities, controls, process validation, and other considerations that ensure batch-to-batch duplication, assurance of identity, and quality of ingredients, as well as freedom from contamination or cross-contamination may vary widely within the silicone elastomer industry. Medical device manufacturers must ensure safety and effectiveness of each specific composition or formulation from each supplier in its intended applications. Historic, clinical, and biocompatibility data are pertinent prospectively only when all compounding, formulating, and fabrication are done in accordance with the provisions of Good Manufacturing Practice Regulations, which help ensure medical materials and devices are reasonably duplicated each time they are manufactured.

1.5 This specification is intended to assist in the development of specifications for formulated silicone elastomer compounds. It is also recommended for use in materials and finished device labeling to specify the type or types of silicone elastomers contained.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM F 1027 : 1986 : R2007 Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices
ASTM F 647 : 1994 : R2000 Standard Practice for Evaluating and Specifying Implantable Shunt Assemblies for Neurosurgical Application
ASTM F 1027 : 1986 : R2017 Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices (Withdrawn 2023)
AAMI NS28 : 1988 : R2015 INTRACRANIAL PRESSURE MONITORING DEVICES
ASTM F 881 : 1994 : R2000 Standard Specification for Silicone Elastomer Facial Implants
ASTM F 982 : 1986 : R2002 Standard Specification for Disclosure of Characteristics of Surgically Implanted Clamps for Carotid Occlusion
ASTM F 647 : 1994 : R2006 Standard Practice for Evaluating and Specifying Implantable Shunt Assemblies for Neurosurgical Application
ASTM F 2051 : 2000 : R2014 Standard Specification for Implantable Saline Filled Breast Prosthesis
BS EN 12010:1998 Non-active surgical implants. Joint replacement implants. Particular requirements
I.S. EN 12010:1998 NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS
AAMI NS28 : 1988 : R2010 INTRACRANIAL PRESSURE MONITORING DEVICES
DIN EN ISO 21534:2009-08 NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS
BS EN ISO 21534:2009 Non-active surgical implants. Joint replacement implants. Particular requirements
ASTM F 647 : 1994 : R2014 Standard Practice for Evaluating and Specifying Implantable Shunt Assemblies for Neurosurgical Application
ASTM F 1027 : 1986 : R2002 Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices
UNI EN ISO 21534 : 2009 NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS
AAMI NS28 : 1988 : R2006 INTRACRANIAL PRESSURE MONITORING DEVICES
ASTM F 1027 : 1986 : R1995 : EDT 1 Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices
ASTM F 982 : 1986 : R1998 Standard Specification for Disclosure of Characteristics of Surgically Implanted Clamps for Carotid Occlusion
I.S. EN ISO 21534:2009 NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS
ASTM F 982 : 1986 : R2008 Standard Specification for Disclosure of Characteristics of Surgically Implanted Clamps for Carotid Occlusion (Withdrawn 2017)
ASTM F 2051 : 2000 Standard Specification for Implantable Saline Filled Breast Prosthesis
ISO 21534:2007 Non-active surgical implants Joint replacement implants Particular requirements
ASTM F 881 : 1994 : R2006 Standard Specification for Silicone Elastomer Facial Implants
ASTM F 1027 : 1986 : R2012 Standard Practice for Assessment of Tissue and Cell Compatibility of Orofacial Prosthetic Materials and Devices
DIN EN ISO 14607:2009-08 NON-ACTIVE SURGICAL IMPLANTS - MAMMARY IMPLANTS - PARTICULAR REQUIREMENTS
ASTM F 881 : 1994 : R2014 Standard Specification for Silicone Elastomer Facial Implants
ASTM F 2051 : 2000 : R2006 Standard Specification for Implantable Saline Filled Breast Prosthesis
EN 12010 : 1998 NON-ACTIVE SURGICAL IMPLANTS - JOINT REPLACEMENT IMPLANTS - PARTICULAR REQUIREMENTS
EN ISO 21534:2009 Non-active surgical implants - Joint replacement implants - Particular requirements (ISO 21534:2007)

ASTM D 926 : 2017 : REDLINE Standard Test Method for Rubber Property—Plasticity and Recovery (Parallel Plate Method)
ASTM D 1349 : 2014 : REDLINE Standard Practice for Rubber—Standard Conditions for Testing
ASTM D 792 : 2013 : REDLINE Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
ASTM F 619 : 2014 : REDLINE Standard Practice for Extraction of Medical Plastics
ASTM D 865 : 2011 Standard Test Method for Rubber<char: emdash>Deterioration by Heating in Air (Test Tube Enclosure)
ASTM F 748 : 2016 : REDLINE Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices
ASTM D 3137 : 1981 : R2018 Standard Test Method for Rubber Property—Hydrolytic Stability
ASTM D 257 : 2014 : REDLINE Standard Test Methods for DC Resistance or Conductance of Insulating Materials
ASTM D 1566 : 2015 : REDLINE TERMINOLOGY RELATING TO RUBBER
ASTM D 570 : 1998 : R2018 Standard Test Method for Water Absorption of Plastics
ASTM D 1418 : 2017 : REDLINE Standard Practice for Rubber and Rubber Latices—Nomenclature

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.