CONTAINED IN VOL. 11.02, 2001 Establishes total number of bacteria contained in 1.0 ml water sample, in which total bacteria count per milliliter is large enough that single sample provides statistically valid sampling.
Committee |
D 19
|
DocumentType |
Test Method
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
1.1 This screening test method covers the detection and enumeration of bacteria contained in a water sample employing a commercial device specifically designed for that purpose. This test method applies only to the enumeration of those viable bacteria that will grow under the test conditions specified (for example, medium, temperature, time, etc.). It is not applicable to the detection of anaerobic bacteria.
1.2 No bacterial culture technique can enumerate all the viable bacteria in a sample, since bacteria occur singly, in pairs, chains, or clusters and no single set of growth conditions or media can satisfy the physiological requirements of all bacteria in a sample. Therefore, this test method cannot provide a total bacterial count, but can only strive to achieve a relative count of viable aerobic and facultative anaerobic bacteria present in a sample.
1.3 The test method applies to samples in which the number of culturable bacteria per millilitre exceeds at least 10 and no more than 160 bacteria/mL in the sample or sample dilution.
1.4 This test method is intended to be used as a simplified field method where bacteriological laboratory facilities are not readily available.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 1094 : 1987 : R2005 | Standard Test Methods for Microbiological Monitoring of Water Used for Processing Electron and Microelectronic Devices by Direct Pressure Tap Sampling Valve and by the Presterilized Plastic Bag Method |
ASTM F 1094 : 1987 : R1999 | Standard Test Methods for Microbiological Monitoring of Water Used for Processing Electron and Microelectronic Devices by Direct Pressure Tap Sampling Valve and by the Presterilized Plastic Bag Method |
ASTM D 6508 : 2015 : REDLINE | Standard Test Method for Determination of Dissolved Inorganic Anions in Aqueous Matrices Using Capillary Ion Electrophoresis and Chromate Electrolyte |
ASTM F 1094 : 1987 : R2012 | Standard Test Methods for Microbiological Monitoring of Water Used for Processing Electron and Microelectronic Devices by Direct Pressure Tap Sampling Valve and by the Presterilized Plastic Bag Method |
ASTM D 1129 : 2013 : REDLINE | Standard Terminology Relating to Water |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.