ASTM F 3160 : 2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Metallurgical Characterization of Absorbable Metallic Materials for Medical Implants
Hardcopy , PDF
03-02-2021
English
05-16-2016
This guidance document provides metallurgical characterization information that may be beneficial in the evaluation of absorbable metallic materials intended for medical implant applications.
Committee |
F 04
|
DocumentType |
Guide
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This guidance document provides metallurgical characterization information that may be beneficial in the evaluation of absorbable metallic materials intended for medical implant applications. This guide is primarily intended for absorbable metallic materials that undergo further processing into a fabricated final device. Therefore, this standard does not require assessments that are more appropriately conducted on the final device, such as biological evaluation. However, a few relevant standards for finished implant devices are included for information purposes.
1.2The purpose of this guide is to identify appropriate test methods and relevant medical product standards that can be used to develop future standards for new or modified absorbable metallic materials.
1.3This guide is not intended to cover other major classes of absorbable materials such as polymers, ceramics, composites, and tissue-engineered materials.
1.4This standard guide is focused on the chemical, physical, microstructural, and mechanical properties plus inspection guidelines for metallic materials that are used for medical implants designed to be absorbed in the body over a period of time. This guide focuses on material characterizations and does not address device specific mechanical testing that may be necessary to determine safety and functionality of the implant.
1.5Compliance with materials specifications developed in accordance with this standard may not necessarily result in a material suitable for its intended purpose. Additional testing specific to the intended use may be required.
1.6Since surface modifications of medical implants are generally applied in the latter stages of manufacturing, this standard guide does not cover the characterization of either absorbable or non-absorbable surface coatings that are metallic in origin such as oxides or from the addition of other materials such as ceramics or polymers. However, this standard does apply to absorbable metallic materials, regardless of the presence or absence of a coating.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 2027 : 2016 : REDLINE | Standard Guide for Characterization and Testing of Raw or Starting Materials for Tissue-Engineered Medical Products |
ASTM F 2502 : 2017 : REDLINE | Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants |
ASTM F 2502 : 2017 | Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants |
ASTM F 3268 : 2018 : REV A | Standard Guide for <emph type="bdit">in vitro</emph> Degradation Testing of Absorbable Metals |
ASTM F 2027 : 2016 | Standard Guide for Characterization and Testing of Raw or Starting Materials for Tissue-Engineered Medical Products |
ASTM F 3268 : 2018 | Standard Guide for <emph type="bdit">in vitro</emph> Degradation Testing of Absorbable Metals |
ISO 404:2013 | Steel and steel products — General technical delivery requirements |
ASTM D 3648 : 2004 : R2011 | Standard Practices for the Measurement of Radioactivity |
ASTM E 1245 : 2003 | Standard Practice for Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis |
ASTM F 2393 : 2010 | Standard Specification for High-Purity Dense Magnesia Partially Stabilized Zirconia (Mg-PSZ) for Surgical Implant Applications |
ASTM B 90/B90M : 2015 : REDLINE | Standard Specification for Magnesium-Alloy Sheet and Plate |
ASTM B 80 : 2015 : REDLINE | Standard Specification for Magnesium-Alloy Sand Castings |
SAE AMS 2248 : 2016 | CHEMICAL CHECK ANALYSIS LIMITS, CORROSION AND HEAT-RESISTANT STEELS AND ALLOYS, MARAGING AND OTHER HIGHLY-ALLOYED STEELS, AND IRON ALLOYS |
ASTM E 1441 : 2000 : R2005 | Standard Guide for Computed Tomography (CT) Imaging |
ASTM A 262 : 2015 : REDLINE | Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels |
ASTM A 480/A480M : 2017-11 | SPECIFICATION FOR GENERAL REQUIREMENTS FOR FLAT-ROLLED STAINLESS AND HEAT-RESISTING STEEL PLATE, SHEET, AND STRIP |
ASTM E 1382 : 1997 : R2015 | Standard Test Methods for Determining Average Grain Size Using Semiautomatic and Automatic Image Analysis |
ASTM E 8/E8M : 2016 : REV A : EDT 1 | Standard Test Methods for Tension Testing of Metallic Materials |
ISO 4967:2013 | Steel — Determination of content of non-metallic inclusions — Micrographic method using standard diagrams |
ASTM E 2627 : 2013 : REDLINE | Standard Practice for Determining Average Grain Size Using Electron Backscatter Diffraction (EBSD) in Fully Recrystallized Polycrystalline Materials |
ASTM E 1245 : 1995 | Standard Practice for Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis |
ASTM F 2052 : 2006 : EDT 1 | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
ASTM F 2213 : 2002 | Standard Test Method for Measurement of Magnetically Induced Torque on Passive Implants in the Magnetic Resonance Environment |
ASTM F 2182 : 2002 | Standard Test Method for Measurement of Radio Frequency Induced Heating Near Passive Implants During Magnetic Resonance Imaging |
SAE AMS 2630 : 2010 | INSPECTION, ULTRASONIC, PRODUCT OVER 0.5 INCH (12.7 MM) THICK |
ASTM F 2213 : 2006 : R2011 | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ASTM E 8/E8M : 2021 | Standard Test Methods for Tension Testing of Metallic Materials |
ASTM E 1441 : 2019 | Standard Guide for Computed Tomography (CT) |
SAE AMS 2632 : 1995 | INSPECTION, ULTRASONIC, OF THIN MATERIALS 0.5 INCH (12.77 MM) AND UNDER IN CROSS-SECTIONAL THICKNESS |
ASTM F 2213 : 2006 | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ASTM E 1245 : 2003 : R2008 | Standard Practice for Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis |
ASTM F 2182 : 2019 : EDT 1 | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM A 342/A342M : 2014 | Standard Test Methods for Permeability of Weakly Magnetic Materials |
ASTM F 2229 : 2012 | Standard Specification for Wrought, Nitrogen Strengthened 23Manganese-21Chromium-1Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29108) |
ASTM E 29 : 2002 | Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications |
ASTM E 45 : 1997 : EDT 2 | Standard Test Methods for Determining the Inclusion Content of Steel |
ISO 3116:2007 | Magnesium and magnesium alloys Wrought magnesium alloys |
ISO/TR 37137:2014 | Cardiovascular biological evaluation of medical devices — Guidance for absorbable implants |
ASTM F 2393 : 2012 : R2016 | Standard Specification for High-Purity Dense Magnesia Partially Stabilized Zirconia (Mg-PSZ) for Surgical Implant Applications |
ASTM A 262 : 2001 | Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels |
ASTM D 3648 : 2014 : REDLINE | Standard Practices for the Measurement of Radioactivity (Withdrawn 2023) |
ASTM F 2182 : 2019 : EDT 2 | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM E 384 : 2017 : REDLINE | Standard Test Method for Microindentation Hardness of Materials |
ASTM F 2229 : 2021 | Standard Specification for Wrought, Nitrogen Strengthened 23Manganese-21Chromium-1Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29108) |
ASTM F 2229 : 2020 | Standard Specification for Wrought, Nitrogen Strengthened 23Manganese-21Chromium-1Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29108) |
ISO 6892-1:2016 | Metallic materials Tensile testing Part 1: Method of test at room temperature |
ASTM E 340 : 2015 : REDLINE | Standard Practice for Macroetching Metals and Alloys |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ASTM D 3648 : 2014 | Standard Practices for the Measurement of Radioactivity (Withdrawn 2023) |
ASTM E 2627 : 2013 : R2019 | Standard Practice for Determining Average Grain Size Using Electron Backscatter Diffraction (EBSD) in Fully Recrystallized Polycrystalline Materials |
ASTM D 3648 : 2003 | Standard Practices for the Measurement of Radioactivity |
ASTM F 2119 : 2007 | Standard Test Method for Evaluation of MR Image Artifacts from Passive Implants |
ASTM D 3648 : 2004 | Standard Practices for the Measurement of Radioactivity |
ASTM F 2052 : 2002 | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
ASTM F 2229 : 2012 : REDLINE | Standard Specification for Wrought, Nitrogen Strengthened 23Manganese-21Chromium-1Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29108) |
ASTM E 2627 : 2013 | Standard Practice for Determining Average Grain Size Using Electron Backscatter Diffraction (EBSD) in Fully Recrystallized Polycrystalline Materials |
ASTM B 953 : 2013 : REDLINE | Standard Practice for Sampling Magnesium and Magnesium Alloys for Spectrochemical Analysis |
ASTM F 2182 : 2019 | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2393 : 2012 | Standard Specification for High-Purity Dense Magnesia Partially Stabilized Zirconia (Mg-PSZ) for Surgical Implant Applications |
ASTM F 2902 : 2016 | Standard Guide for Assessment of Absorbable Polymeric Implants |
ASTM E 2627 : 2010 | Standard Practice for Determining Average Grain Size Using Electron Backscatter Diffraction (EBSD) in Fully Recrystallized Polycrystalline Materials |
ASTM F 2229 : 2002 | Standard Specification for Wrought, Nitrogen Strengthened 23Manganese-21Chromium-1Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29108) |
ASTM B 69 : 2016 : REDLINE | Standard Specification for Rolled Zinc |
ASTM F 2229 : 2007 | Standard Specification for Wrought, Nitrogen Strengthened 23Manganese-21Chromium-1Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29108) |
ASTM F 2393 : 2004 | Standard Specification for High-Purity Dense Magnesia Partially Stabilized Zirconia (Mg-PSZ) for Surgical Implant Applications |
IEEE/ASTM SI_10-2010 | American National Standard for Metric Practice |
ASTM F 2119 : 2001 | Standard Test Method for Evaluation of MR Image Artifacts from Passive Implants |
ASTM E 1382 : 1997 : R2004 | Standard Test Methods for Determining Average Grain Size Using Semiautomatic and Automatic Image Analysis |
ASTM B 557M : 1994 | Standard Test Methods of Tension Testing Wrought and Cast Aluminum- and Magnesium-Alloy Products [Metric] |
ASTM D 3648 : 1995 | Standard Practices for the Measurement of Radioactivity |
ISO/TS 17137:2014 | Cardiovascular implants and extracorporeal systems Cardiovascular absorbable implants |
ASTM F 2052 : 2014 | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
ASTM F 629 : 2015 : REDLINE | Standard Practice for Radiography of Cast Metallic Surgical Implants |
ASTM F 2213 : 2004 | Standard Test Method for Measurement of Magnetically Induced Torque on Passive Implants in the Magnetic Resonance Environment |
ISO 10993-18:2005 | Biological evaluation of medical devices Part 18: Chemical characterization of materials |
ISO 13067:2011 | Microbeam analysis Electron backscatter diffraction Measurement of average grain size |
ISO/TS 10993-19:2006 | Biological evaluation of medical devices Part 19: Physico-chemical, morphological and topographical characterization of materials |
ASTM F 2052 : 2015 : REDLINE | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
ASTM F 2119 : 2007 : R2013 | Standard Test Method for Evaluation of MR Image Artifacts from Passive Implants (Withdrawn 2022) |
ASTM F 2052 : 2006 | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
ASTM E 1245 : 2000 | Standard Practice for Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis |
ASTM E 1441 : 2011 : REDLINE | Standard Guide for Computed Tomography (CT) Imaging |
ASTM F 2581 : 2012 : R2017 | Standard Specification for Wrought Nitrogen Strengthened 11Manganese-17Chromium-3Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29225) |
ASTM F 2213 : 2017 : REDLINE | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ASTM B 557M : 2015 : REDLINE | Standard Test Methods for Tension Testing Wrought and Cast Aluminum- and Magnesium-Alloy Products (Metric) |
ASTM E 536 : 2016 : REDLINE | Standard Test Methods for Chemical Analysis of Zinc and Zinc Alloys |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ASTM F 2182 : 2009 | Standard Test Method for Measurement of Radio Frequency Induced Heating Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2213 : 2017 | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ISO 3815-1:2005 | Zinc and zinc alloys — Part 1: Analysis of solid samples by optical emission spectrometry |
ASTM E 1382 : 1997 : R2010 | Standard Test Methods for Determining Average Grain Size Using Semiautomatic and Automatic Image Analysis |
ASTM F 2052 : 2015 | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
ASTM E 1441 : 2011 | Standard Guide for Computed Tomography (CT) Imaging |
ASTM F 2902 : 2016 : EDT 1 | Standard Guide for Assessment of Absorbable Polymeric Implants |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 643:2012 | Steels Micrographic determination of the apparent grain size |
ASTM B 199 : 2017 : REDLINE | Standard Specification for Magnesium-Alloy Permanent Mold Castings |
ASTM F 2581 : 2007 | Standard Specification for Wrought Nitrogen Strengthened 11Manganese-17Chromium-3Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29225) |
ASTM B 107/B107M : 2013 : REDLINE | Standard Specification for Magnesium-Alloy Extruded Bars, Rods, Profiles, Tubes, and Wire |
ASTM E 290 : 2014 : REDLINE | Standard Test Methods for Bend Testing of Material for Ductility |
ISO 24173:2009 | Microbeam analysis — Guidelines for orientation measurement using electron backscatter diffraction |
ASTM E 1382 : 1997 | Standard Test Methods for Determining Average Grain Size Using Semiautomatic and Automatic Image Analysis |
ASTM E 1245 : 2003 : R2016 | Standard Practice for Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis |
ASTM A 342/A342M : 2014 : REDLINE | Standard Test Methods for Permeability of Weakly Magnetic Materials |
ASTM A 555/A555M : 2016 : REDLINE | Standard Specification for General Requirements for Stainless Steel Wire and Wire Rods |
ASTM F 2581 : 2012 | Standard Specification for Wrought Nitrogen Strengthened 11Manganese-17Chromium-3Molybdenum Low-Nickel Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S29225) |
ASTM A 342/A342M : 2021 | Standard Test Methods for Permeability of Weakly Magnetic Materials |
ASTM F 2902 : 2012 | Standard Guide for Assessment of Absorbable Polymeric Implants |
ASTM B 661 : 2012 : REDLINE | Standard Practice for Heat Treatment of Magnesium Alloys |
ASTM F 2182 : 2011 : REV A | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM B 403 : 2012 : REDLINE | Standard Specification for Magnesium-Alloy Investment Castings |
ISO 3815-2:2005 | Zinc and zinc alloys — Part 2: Analysis by inductively coupled plasma optical emission spectrometry |
ASTM E 354 : 2014 : REDLINE | Standard Test Methods for Chemical Analysis of High-Temperature, Electrical, Magnetic, and Other Similar Iron, Nickel, and Cobalt Alloys |
ISO 16220:2017 | Magnesium and magnesium alloys — Magnesium alloy ingots and castings |
ASTM F 2052 : 2000 | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Passive Implants in the Magnetic Resonance Environment |
ASTM E 8/E8M : 2016-09 | TEST METHODS FOR TENSION TESTING OF METALLIC MATERIALS |
ASTM E 1441 : 2000 | Standard Guide for Computed Tomography (CT) Imaging |
ASTM B 954 : 2015 : REDLINE | Standard Test Method for Analysis of Magnesium and Magnesium Alloys by Atomic Emission Spectrometry |
ASTM F 2182 : 2002 : REV A | Standard Test Method for Measurement of Radio Frequency Induced Heating Near Passive Implants During Magnetic Resonance Imaging |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.