Standard Specification for Series 10 Poly(Vinyl Chloride) (PVC) Closed Profile Gravity Pipe and Fittings Based on Controlled Inside Diameter (Withdrawn 2011)

Available format(s)

Hardcopy , PDF

Withdrawn date

08-03-2011

Language(s)

English

Published date

08-10-2003

US$75.00
Excluding Tax where applicable

CONTAINED IN VOL. 08.04, 2011 Defines requirements for 10 psi pipe stiffness poly(vinyl chloride) (PVC) closed profile sewer pipe and fittings with integral bell and elastomeric seal joints or plain end pipe with couplings in sizes (18 to 60 in.) based on a controlled inside diameter.

Committee
F 17
DocumentType
Standard
Pages
5
PublisherName
American Society for Testing and Materials
Status
Withdrawn

1.1 This specification covers requirements for 10 psi pipe stiffness poly(vinyl chloride) (PVC) closed profile sewer pipe and fittings with integral bell and elastomeric seal joints or plain end pipe with couplings in sizes (18 to 60 in.) based on a controlled inside diameter.

1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 The following safety hazard caveat pertains only to the test methods portion, Section , of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 1—Pipe and fittings produced to this specification should be installed in accordance with Practice D 2321.

MIL-STD-129 Revision R:2014 Military Marking for Shipment and Storage
ASTM D 618 : 2013 : REDLINE Standard Practice for Conditioning Plastics for Testing
ASTM F 679 : 2016 : REDLINE Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings
ASTM F 477 : 2014 : REDLINE Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
ASTM D 2855 : 2015 : REDLINE Standard Practice for the Two-Step (Primer and Solvent Cement) Method of Joining Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Piping Components with Tapered Sockets
FED-STD-123 Revision H:2007 MARKING FOR SHIPMENT (CIVIL AGENCIES)
ASTM D 2444 : 1999 Standard Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight)
ASTM D 2122 : 2016 : REDLINE Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
ASTM D 1784 : 2011 : REDLINE Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.