ASTM E 2813 : 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Building Enclosure Commissioning
Hardcopy , PDF
11-11-2014
English
02-01-2012
CONTAINED IN VOL. 04.12, 2015 Defines a concise, authoritative, and technically sound practice for Building Enclosure Commissioning (BECx) that establishes two levels of BECx: Fundamental and Enhanced
Committee |
E 06
|
DocumentType |
Standard Practice
|
Pages |
19
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This practice is intended to serve as a concise, authoritative, and technically sound practice for Building Enclosure Commissioning (BECx) that establishes two levels of BECx: Fundamental and Enhanced (refer also to Section 4).
1.2 The BECx process as defined in this practice includes the following phases and sub-phases:
1.2.1 Pre-design,
1.2.2 Design,
1.2.2.1 Schematic Design,
1.2.2.2 Design Development,
1.2.2.3 Construction Documentation,
1.2.3 Pre-Construction,
1.2.4 Construction, and
1.2.5 Occupancy and Operations.
1.3 This practice includes a mandatory OPR Development Guideline (Annex A1) and requires the development of an OPR for both Fundamental and Enhanced BECx that addresses, at a minimum, the performance attributes and metrics included in Annex A1 of this practice.
1.4 This practice includes mandatory BECx Performance Testing Requirements (Annex A2) approved for use with this practice to evaluate the performance and durability of enclosure materials, components, systems, and assemblies.
1.5 This practice mandates independent, third-party design peer review during the Design Phase of both Fundamental and Enhanced BECx.
1.6 This practice recognizes that the OPR for exterior enclosure performance and environmental separation may exceed the baseline requirements of applicable building codes and standards and provides guidance for the development of an OPR based on the following attributes as defined in Annex A1 of this practice:
1.6.1 Energy,
1.6.2 Environment,
1.6.3 Safety,
1.6.4 Security,
1.6.5 Durability,
1.6.6 Sustainability, and
1.6.7 Operation.
1.7 The terms “building enclosure” and “enclosure” as they appear in this practice refer collectively to all materials, components, systems, and assemblies intended to provide shelter and environmental separation between interior and exterior, or between two or more environmentally distinct interior spaces in a building or structure.
1.8 This practice establishes that the Building Enclosure Commissioning “Agent” or “Authority” (BECxA) refers specifically to the individual or firm retained by the Owner to develop, manage, and be in responsible charge of the BECx process, including individual members and technical specialists that may comprise the BECx team (see 4.2).
1.9 The role and responsibilities of the BECxA as defined by this practice are not intended to supersede or otherwise replace the contractual obligations reserved specifically for the parties responsible for the design and construction of a building or structure, nor the duties that may otherwise be assigned to those parties by applicable regulatory or statutory law.
1.10 This practice is not intended to warrant or otherwise guarantee the as-built or in-service durability, or both, and performance of enclosure materials, components, systems, and assemblies.
1.11 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 2947 : 2016 : REV A | Standard Guide for Building Enclosure Commissioning |
ASTM E 1050 : 2012 : REDLINE | Standard Test Method for Impedance and Absorption of Acoustical Materials Using a Tube, Two Microphones and a Digital Frequency Analysis System |
ASTM C 423 : 2017 : REDLINE | Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method |
ASTM C 510 : 2016 : REDLINE | Standard Test Method for Staining and Color Change of Single- or Multicomponent Joint Sealants |
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ASHRAE 101 : 1981 | APPLICATION OF INFRARED SENSING DEVICES TO THE ASSESSMENT OF BUILDING HEAT LOSS CHARACTERISTICS |
ASHRAE GUIDELINE 0 : 2013 | THE COMMISSIONING PROCESS |
ASTM E 1105 : 2015 : REDLINE | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference |
ASTM E 1996 : 2017 : REDLINE | Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes |
ASTM C 1294 : 2015 : REDLINE | Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials |
ASTM E 576 : 2014 : REDLINE | Standard Test Method for Frost/Dew Point of Sealed Insulating Glass Units in the Vertical Position |
ASTM D 4541 : 2017 : REDLINE | Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers |
ANSI S12.60 : 0 | ACOUSTICAL PERFORMANCE CRITERIA, DESIGN REQUIREMENTS, AND GUIDELINES FOR SCHOOLS |
ASHRAE 90.1 : 1999 | ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS |
ASTM C 1193 : 2016 : REDLINE | Standard Guide for Use of Joint Sealants |
ASTM E 2570 : 2007 | Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage |
ASTM E 1503 : 2014 : REDLINE | Standard Test Method for Conducting Outdoor Sound Measurements Using a Digital Statistical Sound Analysis System |
ASTM E 903 : 2012 | Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres |
ASTM E 795 : 2016 : REDLINE | Standard Practices for Mounting Test Specimens During Sound Absorption Tests |
ASTM C 1549 : 2016 : REDLINE | Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer |
ASTM C 1246 : 2017 : REDLINE | Standard Test Method for Effects of Heat Aging on Weight Loss, Cracking, and Chalking of Elastomeric Sealants After Cure |
ASTM E 331 : 2000 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASTM E 2359 : 2006 | Standard Test Method for Field Pull Testing of an In-Place Exterior Insulation and Finish System Clad Wall Assembly |
ASTM C 732 : 2017 : REDLINE | Standard Test Method for Aging Effects of Artificial Weathering on Latex Sealants |
ASTM E 2353 : 2016 : REDLINE | Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades |
ASTM E 2649 : 2012 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy |
ASTM E 2179 : 2003 | Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
ASTM C 1371 : 2015 : REDLINE | Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers |
ASTM E 1425 : 2014 : REDLINE | Standard Practice for Determining the Acoustical Performance of Windows, Doors, Skylight, and Glazed Wall Systems |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
ASTM C 1087 : 2016 : REDLINE | Standard Test Method for Determining Compatibility of Liquid-Applied Sealants with Accessories Used in Structural Glazing Systems |
ASTM E 488 : 1996 | Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements |
ASTM E 1186 : 2017 : REDLINE | Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems |
ASTM E 1014 : 2012 : REDLINE | Standard Guide for Measurement of Outdoor A-Weighted Sound Levels |
ASTM E 1980 : 2011 | Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surfaces |
ASTM C 1279 : 2013 : REDLINE | TEST METHOD FOR NON-DESTRUCTIVE PHOTOELASTIC MEASUREMENT OF EDGE AND SURFACE STRESSES IN ANNEALED, HEAT-STRENGTHENED, AND FULLY TEMPERED FLAT GLASS |
ASTM E 997 : 2015 : REDLINE | Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing |
ASTM E 2178 : 2013 : REDLINE | Standard Test Method for Air Permeance of Building Materials |
CGSB 149-GP-2MP : 1986 | MANUAL FOR THERMOGRAPHIC ANALYSIS OF BUILDING ENCLOSURES |
CSA A123.21 : 2014 | STANDARD TEST METHOD FOR THE DYNAMIC WIND UPLIFT RESISTANCE OF MEMBRANE-ROOFING SYSTEMS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.