ASTM E 2594 : 2009 : R2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Analysis of Nickel Alloys by Inductively Coupled Plasma Atomic Emission Spectrometry (Performance-Based Method)
Hardcopy , PDF
03-02-2020
English
06-24-2014
CONTAINED IN VOL. 03.05, 2014 Specifies the inductively coupled plasma atomic emission spectrometric analysis of nickel alloys.
Committee |
E 01
|
DocumentType |
Test Method
|
Pages |
10
|
ProductNote |
Reconfirmed 2014
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method describes the inductively coupled plasma atomic emission spectrometric analysis of nickel alloys, such as specified by Committee B02, and having chemical compositions within the following limits:
Element | Application |
Aluminum | 0.01–1.00 |
Boron | 0.001–0.050 |
Calcium | 0.001–0.05 |
Carbon | 0.10–0.20 |
Chromium | 0.01–33.0 |
Cobalt | 0.10–20.0 |
Copper | 0.01–3.00 |
Iron | 0.01–50.0 |
Lead | 0.001–0.01 |
Magnesium | 0.0001–0.100 |
Manganese | 0.01–3.0 |
Molybdenum | 0.01–30.0 |
Niobium | 0.01–6.0 |
Nickel | 25.0–80.0 |
Nitrogen | 0.001–0.20 |
Oxygen | 0.0001–0.003 |
Phosphorous | 0.001–0.030 |
Sulfur | 0.0001–0.010 |
Silicon | 0.01–1.50 |
Tantalum | 0.005–0.10 |
Tin | 0.001–0.020 |
Titanium | 0.001–6.0 |
Tungsten | 0.01–5.0 |
Vanadium | 0.01–1.0 |
Zirconium | 0.01–0.10 |
1.2The following elements may be determined using this test method. The test method user should carefully evaluate the precision and bias statements of this test method to determine applicability of the test method for the intended use.
Element | Quantification |
Aluminum | 0.060–1.40 |
Boron | 0.002–0.020 |
Calcium | 0.001–0.003 |
Copper | 0.010–0.52 |
Magnesium | 0.001–0.10 |
Manganese | 0.002–0.65 |
Niobium | 0.020–5.5 |
Phosphorous | 0.004–0.030 |
Tantalum | 0.010–0.050 |
Tin | 0.002–0.018 |
Titanium | 0.020–3.1 |
Tungsten | 0.007–0.11 |
Vanadium | 0.010–0.50 |
Zirconium | 0.002–0.10 |
1.3This test method has only been interlaboratory tested for the elements and ranges specified. It may be possible to extend this test method to other elements or different concentration ranges provided that method validation is performed that includes evaluation of method sensitivity, precision, and bias as described in this document. Additionally, the validation study must evaluate the acceptability of sample preparation methodology using reference materials or spike recoveries, or both. The user is cautioned to carefully evaluate the validation data against the laboratory’s data quality objectives. Method validation of scope extensions is also a requirement of ISO/IEC 17025.
1.4The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are given in 8.2.6.3 and safety hazard statements are given in Section 9.
ASTM E 1473 : 2016 | Standard Test Methods for Chemical Analysis of Nickel, Cobalt and High-Temperature Alloys |
ASTM F 3049 : 2014 | Standard Guide for Characterizing Properties of Metal Powders Used for Additive Manufacturing Processes |
ASTM E 2027 : 2017 : EDT 1 | Standard Practice for Conducting Proficiency Tests in the Chemical Analysis of Metals, Ores, and Related Materials (Withdrawn 2022) |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ASTM E 1479 : 2016 | Standard Practice for Describing and Specifying Inductively Coupled Plasma Atomic Emission Spectrometers |
ASTM E 1479 : 1999 : R2005 | Standard Practice for Describing and Specifying Inductively-Coupled Plasma Atomic Emission Spectrometers |
ASTM D 1193 : 1977 : R1983 : EDT 1 | Standard Specification for Reagent Water |
ASTM E 50 : 2017 : REDLINE | Standard Practices for Apparatus, Reagents, and Safety Considerations for Chemical Analysis of Metals, Ores, and Related Materials |
ASTM E 1329 : 2000 : R2005 | Standard Practice for Verification and Use of Control Charts in Spectrochemical Analysis |
ASTM E 2027 : 2009 | Standard Practice for Conducting Proficiency Tests in the Chemical Analysis of Metals, Ores, and Related Materials |
ASTM E 2027 : 2017 | Standard Practice for Conducting Proficiency Tests in the Chemical Analysis of Metals, Ores, and Related Materials |
ASTM E 1479 : 2016 : REDLINE | Standard Practice for Describing and Specifying Inductively Coupled Plasma Atomic Emission Spectrometers |
ASTM D 1193 : 2006 : R2011 | Standard Specification for Reagent Water |
ASTM E 1601 : 2019 | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM E 1601 : 1998 | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM E 1601 : 2010 | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM E 1329 : 2010 | Standard Practice for Verification and Use of Control Charts in Spectrochemical Analysis (Withdrawn 2019) |
ASTM E 1479 : 1999 : R2011 | Standard Practice for Describing and Specifying Inductively-Coupled Plasma Atomic Emission Spectrometers |
ASTM E 1329 : 2000 | Standard Practice for Verification and Use of Control Charts in Spectrochemical Analysis |
ASTM E 1601 : 2012 : REDLINE | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM D 1193 : 1991 | Standard Specification for Reagent Water |
ASTM E 1601 : 2012 | Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method |
ASTM E 2027 : 1999 | Standard Practice for Conducting Proficiency Tests in the Chemical Analysis of Metals, Ores, and Related Materials |
ASTM E 2027 : 2005 | Standard Practice for Conducting Proficiency Tests in the Chemical Analysis of Metals, Ores, and Related Materials |
ASTM D 1193 : 1970 | Standard Specification For Reagent Water |
ASTM D 1193 : 2006 | Standard Specification for Reagent Water |
ASTM D 1193 : 1999 | Standard Specification for Reagent Water |
ISO Guide 31:2015 | Reference materials — Contents of certificates, labels and accompanying documentation |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
ISO Guide 34:2009 | General requirements for the competence of reference material producers |
ASTM E 1479 : 1999 | Standard Practice for Describing and Specifying Inductively-Coupled Plasma Atomic Emission Spectrometers |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.