• There are no items in your cart

ASTM E 251 : 2020 : REV A

Current

Current

The latest, up-to-date edition.

Standard Test Methods for Performance Characteristics of Metallic Bonded Resistance Strain Gages

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

08-01-2020

US$90.00
Excluding Tax where applicable

Committee
E 28
DocumentType
Test Method
Pages
21
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1The purpose of these test methods are to provide uniform test methods for the determination of strain gage performance characteristics. Suggested testing equipment designs are included.

1.2Test Methods E251 describes methods and procedures for determining five strain gage performance characteristics:

Section

Part I—General Requirements

7

Part II—Resistance at a Reference Temperature

8

Part III—Gage Factor at a Reference Temperature

9

Part IV—Temperature Coefficient of Gage Factor

10

Part V—Transverse Sensitivity

11

Part VI—Thermal Output

12

1.3Strain gages are very sensitive devices with essentially infinite resolution. Their response to strain, however, is low and great care must be exercised in their use. The performance characteristics identified by these test methods must be known to an acceptable accuracy to obtain meaningful results in field applications.

1.3.1Strain gage resistance is used to balance instrumentation circuits and to provide a reference value for measurements since all data are related to a change in the strain gage resistance from a known reference value.

1.3.2Gage factor is the transfer function of a strain gage. It relates resistance change in the strain gage and strain to which it is subjected. Accuracy of strain gage data can be no better than the accuracy of the gage factor.

1.3.3Changes in gage factor as temperature varies also affect accuracy although to a much lesser degree since variations are usually small.

1.3.4Transverse sensitivity is a measure of the strain gage's response to strains perpendicular to its measurement axis. Although transverse sensitivity is usually much less than 10 % of the gage factor, large errors can occur if the value is not known with reasonable precision.

1.3.5Thermal output is the response of a strain gage to temperature changes. Thermal output is an additive (not multiplicative) error. Therefore, it can often be much larger than the strain gage output from structural loading. To correct for these effects, thermal output must be determined from strain gages bonded to specimens of the same material on which the tests are to run, often to the test structure itself.

1.4Metallic bonded resistance strain gages differ from extensometers in that they measure average unit elongation (ΔL/L) over a nominal gauge length rather than total elongation between definite gauge points. Practice E83 is not applicable to these strain gages.

1.5These test methods do not apply to transducers, such as load cells and extensometers, that use bonded resistance strain gages as sensing elements.

1.6Strain gages are part of a complex system that includes structure, adhesive, strain gage, lead wires, instrumentation, and (often) environmental protection. As a result, many things affect the performance of strain gages, including user technique. A further complication is that strain gages once installed normally cannot be reinstalled in another location. Therefore, strain gage characteristics can be stated only on a statistical basis.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E 83 : 2023 Standard Practice for Verification and Classification of Extensometer Systems
ASTM E 83 : 2000 : EDT 1 Standard Practice for Verification and Classification of Extensometer
ASTM E 228 : 2017 Standard Test Method for Linear Thermal Expansion of Solid Materials With a Push-Rod Dilatometer
ASTM E 83 : 2016 Standard Practice for Verification and Classification of Extensometer Systems
ASTM E 83 : 1998 : EDT 1 Standard Practice for Verification and Classification of Extensometer
ASTM E 6 : 2002 Standard Terminology Relating to Methods of Mechanical Testing
ASTM E 6 : 2015 : EDT 3 Standard Terminology Relating to Methods of Mechanical Testing
ASTM E 6 : 2023 : REV A Standard Terminology Relating to Methods of Mechanical Testing
ASTM E 6 : 2015 : EDT 4 : REDLINE Standard Terminology Relating to Methods of Mechanical Testing
ASTM E 6 : 2015 : EDT 4 Standard Terminology Relating to Methods of Mechanical Testing
ASTM E 6 : 2023 Standard Terminology Relating to Methods of Mechanical Testing
ASTM E 228 : 2022 Standard Test Method for Linear Thermal Expansion of Solid Materials With a Push-Rod Dilatometer

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.