ASTM E 2353 : 2016 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades

Available format(s)

PDF

Superseded date

07-02-2021

Language(s)

English

Published date

02-15-2016

US$75.00
Excluding Tax where applicable

CONTAINED IN VOL. 04.12, 2016 Defines procedures to be followed in testing the performance of glazing in permanent railing systems, guards and balustrades including components such as rails and swing gates or other forms of required guardrail opening protection installed in and for assembly, commercial, educational, industrial, institutional, stadiums, recreational, and residential buildings and other structures such as towers or elevated platforms.

Committee
E 06
DocumentType
Redline
Pages
11
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1These test methods cover procedures to be followed in testing the performance of glazing in permanent railing systems, guards and balustrades including components such as rails and swing gates or other forms of required guardrail opening protection installed in and for assembly, commercial, educational, industrial, institutional, stadiums, recreational, and residential buildings and other structures such as towers or elevated platforms.

1.2These test methods are applicable to such railing, guard, and balustrade systems having glass or other glazing materials as the major structural component or the infill panel including swing gates and other forms of guardrail protection.

1.3These test methods can be used to determine whether permanent rails, guards and balustrades including components, having glass or other glazing material comply with requirements of performance specifications, codes, norms, and standards.

1.4Specifically, these test methods cover procedures for determining the static strength, impact performance, and post-breakage characteristics of railing systems, guards, and balustrades, including a component with glass or other glazing material installed in one, two, three and four-side support systems fastened to concrete, masonry, wood, metal, and related products.

1.5No consideration is given in these test methods to any possible deterioration of the railing, guard, or balustrade system or their connections and fasteners as resulting from adverse environmental or in-service conditions. The performance of special tests covering this aspect may be desirable.

1.6These test methods are limited to the application of loads and impact resistance described herein. Whenever uniformly distributed loads are to be resisted by a railing system, guard, or balustrade in accordance with governing specifications, codes, norms, and standards, the effects of such loads on the member stresses shall be determined by calculation and the corresponding concentrated and linear loads shall be tested. Should computations make it possible to provide the needed information, testing can be employed for verification.

1.7These test methods address the capability of glass or other glazing material supported by rails, guards, or balustrades, or both, in one, two, three, and four-sided support systems to continue in their function as a barrier by remaining in the designed framing system after impact or glazing breakage. These test methods do not address structural limitation of glazed or glass rails, guards, and balustrades or vehicular guards except when in the area of a pedestrian walkway.

1.8All values are stated in SI units and are to be regarded as standard. Values given in parentheses are for information only. Certain values contained in reference documents cited and quoted herein may be stated in inch-pound units and must be converted by the user.

1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 2358 : 2017 : REDLINE Standard Specification for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades
CSA Z320 : 2011 : R2016 BUILDING COMMISSIONING
ASTM E 2813 : 2012 Standard Practice for Building Enclosure Commissioning
CSA Z320 : 2011 : INC : UPD 1 : 2011 BUILDING COMMISSIONING
CSA Z320 : 2011 BUILDING COMMISSIONING
ASTM E 2813 : 2012 : EDT 1 Standard Practice for Building Enclosure Commissioning
A500-16 Building guards
CSA Z8001 : 2013 COMMISSIONING OF HEALTH CARE FACILITIES

ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ANSI Z97.1 : 2015 SAFETY GLAZING MATERIALS USED IN BUILDINGS - SAFETY PERFORMANCE SPECIFICATIONS AND METHODS OF TEST
CFR 16(PTS1000-END) : 0 COMMERCIAL PRACTICES - FEDERAL TRADE COMMISSION - CONSUMER PRODUCT SAFETY COMMISSION
ASTM E 2358 : 2017 : REDLINE Standard Specification for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades
ASTM E 699 : 2016 : REDLINE Standard Specification for Agencies Involved in Testing, Quality Assurance, and Evaluating of Manufactured Building Components

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.