ASTM E 2303 : 2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
Hardcopy , PDF
11-11-2014
English
07-10-2003
Committee |
E 61
|
DocumentType |
Guide
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This document provides guidance in determining absorbed-dose distributions in products, materials or substances irradiated in gamma, X-ray (bremsstrahlung) and electron beam facilities.
Note 1—For irradiation of food and the radiation sterilization of health care products, other specific ISO and ISO/ASTM standards containing dose mapping requirements exist. For food irradiation, see ISO/ASTM 51204, Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing and ISO/ASTM 51431, Practice for Dosimetry in Electron and Bremsstrahlung Irradiation Facilities for Food Processing. For the radiation sterilization of health care products, see ISO 11137: 1995, Sterilization of Health Care Products Requirements for Validation and Routine Control Radiation Sterilization. In those areas covered by ISO 11137, that standard takes precedence. ISO/ASTM Practice 51608, ISO/ASTM Practice 51649, and ISO/ASTM Practice 51702 also contain dose mapping requirements.
1.2 Methods of analyzing the dose map data are described. Examples are provided of statistical methods that may be used to analyze dose map data.
1.3 Dose mapping for bulk flow processing and fluid streams is not discussed.
1.4 Dosimetry is only one component of a total quality program for an irradiation facility. Other controls besides dosimetry may be required for specific applications such as medical device sterilization and food preservation.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
ASTM E 1608 : 2015 | Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV |
ASTM E 2628 : 2013 | PRACTICE FOR DOSIMETRY FOR RADIATION PROCESSING |
ASTM E 1818 : 2013 | PRACTICE FOR DOSIMETRY IN AN ELECTRON BEAM FACILITY FOR RADIATION PROCESSING AT ENERGIES BETWEEN 80 AND 300 KEV |
ASTM E 1940 : 2013 | Standard Guide for Dosimetry for Sterile Insect Release Programs |
ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
ASTM E 1702 : 2013 | PRACTICE FOR DOSIMETRY IN A GAMMA IRRADIATION FACILITY FOR RADIATION PROCESSING |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.