ASTM E 2190 : 2019
Current
The latest, up-to-date edition.
Standard Specification for Insulating Glass Unit Performance and Evaluation
Hardcopy , PDF
English
04-01-2019
This specification covers preassembled permanently sealed insulating glass units with one or two cavities and preassembled insulating glass (IG) units with capillary tubes intentionally left open or closed.
Committee |
E 06
|
DocumentType |
Standard
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This specification covers preassembled permanently sealed insulating glass units with one or two cavities and preassembled insulating glass (IG) units with capillary tubes intentionally left open or closed.
1.2This specification is applicable only to insulating glass units that are constructed with glass or suspended film.
1.3This specification is applicable to both double-glazed and triple-glazed insulating glass units; for triple-glazed insulating glass units where both of the outer lites are glass and middle lite is either glass or a suspended film.
1.4The qualification of test specimens is based on frost/dew point and on the absence of fog after the specified test durations.
1.5The qualification of argon gas-filled test specimens is based on maintaining the specified argon gas amounts before and after testing to Test Method E2188.
1.6Qualification under this specification is intended to provide a basis for evaluating the durability of insulating glass units.
1.7This specification is not applicable to insulating glass units containing a spandrel glass coating due to test method limitations.
1.8This specification does not cover other physical requirements such as appearance, thermophysical properties, heat and light transmission, and glass displacement.
Note 1:Insulating glass units qualified according to this specification are not necessarily suitable for structurally glazed applications. Factors such as sealant longevity when exposed to long term ultraviolet light and the structural properties of the sealant must be reviewed for these applications. For more information on the requirements for structural sealant glazing applications, refer to Specification C1369, Guide C1249, and Test Method C1265.
1.9The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.10This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.11This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E 2953 : 2014 | Standard Specification for Evaluating Accelerated Aging Performance of Electrochromic Devices in Sealed Insulating Glass Units |
ASTM E 2189 : 2019 | Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units |
ASTM E 2649 : 2012 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy |
ASTM E 2188 : 2019 | Standard Test Method for Insulating Glass Unit Performance |
ASTM C 1249 : 2018 | Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications |
ASTM E 3120 : 2017 | Standard Specification for Evaluating Accelerated Aging Performance of Environmentally Controlled Dynamic Glazings |
ASTM C 1036 : 2001 | Standard Specification for Flat Glass |
ASTM E 2269 : 2005 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units using Gas Chromatography |
ASTM E 2189 : 2019 | Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units |
ASTM E 2188 : 2010 | Standard Test Method for Insulating Glass Unit Performance |
ASTM C 1036 : 2021 | Standard Specification for Flat Glass |
ASTM E 2649 : 2009 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy |
ASTM C 1036 : 2006 | Standard Specification for Flat Glass |
ASTM C 1265 : 1994 : R2011 | Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications |
ASTM C 1369 : 2007 | Standard Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units |
ASTM E 2269 : 2003 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units using Gas Chromatography |
ASTM C 717 : 2019 | Standard Terminology of Building Seals and Sealants |
ASTM C 1265 : 1994 : R2005 : EDT 1 | Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications |
ASTM C 1369 : 2019 | Standard Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units |
ASTM C 1249 : 2006 | Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications |
ASTM C 1265 : 2017 | Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications |
ASTM C 1036 : 2016 | Standard Specification for Flat Glass |
ASTM C 1369 : 2007 : R2014 | Standard Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units |
ASTM E 2189 : 2010 | Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units |
ASTM C 1036 : 2011 | Standard Specification for Flat Glass |
ASTM E 631 : 2015 : R2024 | Standard Terminology of Building Constructions |
ASTM C 1249 : 2018 : R2023 | Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications |
ASTM E 2649 : 2012 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy |
ASTM C 1249 : 1993 | Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications |
ASTM C 162 : 2005 : R2015 | Standard Terminology of<brk type="line"/> Glass and Glass Products |
ASTM C 1265 : 1994 : R1999 | Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications |
ASTM E 631 : 2015 | Standard Terminology of Building Constructions |
ASTM E 2188 : 2002 | Standard Test Method for Insulating Glass Unit Performance |
ASTM C 162 : 2023 | Standard Terminology of Glass and Glass Products |
ASTM C 1249 : 2018 | Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications |
ASTM E 2189 : 2010 : EDT 1 | Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units |
ASTM E 2649 : 2020 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy |
ASTM C 717 : 2024 | Standard Terminology of Building Seals and Sealants |
ASTM C 1036 : 2011 : EDT 1 | Standard Specification for Flat Glass |
ASTM C 1369 : 1997 | Standard Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units |
ASTM C 1369 : 2002 | Standard Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units |
ASTM E 2269 : 2014 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units using Gas Chromatography |
ASTM E 2269 : 2021 | Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units using Gas Chromatography |
ASTM C 1265 : 2022 | Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications |
ASTM E 2189 : 2002 | Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units |
ASTM C 1036 : 1991 : R1997 | Standard Specification for Flat Glass |
ASTM E 2188 : 2019 | Standard Test Method for Insulating Glass Unit Performance |
ASTM C 1249 : 2006 : REV A | Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications |
ASTM C 1249 : 2006 : REV A : R2010 | Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.