ASTM E 2112 : 2007 : R2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Installation of Exterior Windows, Doors and Skylights
Hardcopy , PDF
11-20-2017
English
01-01-2016
CONTAINED IN VOL. 04.11, 2018 Defines the installation of fenestration products in new and existing construction.
Committee |
E 06
|
DocumentType |
Standard Practice
|
Pages |
88
|
ProductNote |
Reconfirmed 2016
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This practice covers the installation of fenestration products in new and existing construction. For the purpose of this practice, fenestration products shall be limited to windows, sliding patio-type doors, swinging patio type doors, and skylights, as used primarily in residential and light commercial buildings.
1.2This practice assumes that the installer possesses basic woodworking skills and an understanding of wall and roof construction, sheet metal work, and joint sealant practices.
1.3This practice attempts to instruct and familiarize the installer with the concepts of both Barrier Systems and Membrane/Drainage Systems, in order to ensure the continuity of the building envelope. This practice attempts to educate the installer, builder, architect, and other users in the identification and understanding of the water shedding system of the building envelope.
1.4This practice covers the installation process from pre-installation procedures through post-installation procedures, for single units or factory-mulled multiple units in a single opening. It does not cover the fabrication or assembly of multiple units, whether such fabrication takes place in a factory or at the intended installation site. The installer should check with the manufacturer of factory-assembled units for instructions for anchoring. When using field-mulled units, follow manufacturer's recommendations and make certain that they meet applicable codes. This practice does not cover the selection of appropriate fenestration products for a given application, nor the selection of other products or systems for use in the installation.
1.5This practice provides minimum requirements that will help to accomplish the installation of fenestration products in an effective manner. Actual conditions in buildings vary greatly and, in some cases, substantial additional precautions may be required. In the event that the manufacturer's installation instructions provided with the product conflict with requirements of this practice, the manufacturer's instructions shall prevail. This practice is not intended to limit or exclude other new procedures that may refine or further improve the effectiveness of fenestration installation.
1.5.1This practice is intended to be used for background information in order to develop training manuals and training programs. Further, this practice attempts to consolidate and unify the various steps of construction, tying together the various trades involved with the continuity between fenestration products and the building envelope.
1.6The text of this practice references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this practice.
1.7The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.8This standard has not been created to address all issues related to every possible installation situation one might experience in the field. Furthermore, this practice does not purport to provide fail-safe installation methods, assurance or protection against installation deficiencies, or a standard by which architects can specify or ensure delivered performance.
Note 1:There are no ISO standards covering the primary subject matter of this practice.
1.9This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 5, Related Procedures. Where a lead hazard is known or suspected, refer to ASTM Standards on Lead Hazards Associated with Buildings and to applicable state and federal regulations. Where an asbestos hazard is known or suspected, refer to the ASTM Manual on Asbestos Control, and to applicable state and federal regulations.
1.10Table of Contents:
Section | |
Scope | 1 |
Table of Contents | 1.10 |
Referenced Documents | 2 |
Terminology | 3 |
Definitions | 3.1 |
Description of Terms Specific to this Standard | 3.2 |
Abbreviations | 3.3 |
Significance and Use | 4 |
Related Issues and Procedures | 5 |
Continuity with the Weather Barrier Systems | 5.1 |
Joints and Anchorages | 5.2 |
Moisture Entrapment | 5.3 |
Weather Resistant Barrier | 5.4 |
Weatherability | 5.5 |
Construction Sequence | 5.6 |
Construction Damage | 5.7 |
Inspection | 5.8 |
Rough Opening | 5.9 |
Rough Opening Size | 5.9.1 |
Insulating or Filling the Rough Opening Gap | 5.9.2 |
Materials Protection | 5.10 |
Cleaning and Maintenance | 5.11 |
Dissimilar Materials | 5.12 |
Flashing Requirements | 5.13 |
Fastening Systems/Anchorage | 5.14 |
Shimming | 5.15 |
Panning Systems and Subsills for Weatherability | 5.16 |
Pre-Installation Procedures | 5.17 |
Sealants—Selection and Use | 5.18 |
Window Cleaner Anchors and Related Safety | 5.19 |
Continuity Between the Fenestration Products and | 6 |
Water Shedding Strategies of Wall and Roof Systems | 7 |
Concept of Surface Barrier Systems and | 7.1 |
Surface Barrier Systems | 7.1.1 |
Membrane/Drainage Systems | 7.1.2 |
Identification of Systems | 7.2 |
Installation Methods For Windows | 8 |
Windows in Walls Utilizing a Membrane/Drainage | 8.1 |
Windows with Perimeter Mounting Flanges | 8.1.1 |
Flange Types | 8.1.1.1 |
Selection of Installation Method | 8.1.1.2 |
Method A | 8.1.1.3.1 |
Method B | 8.1.1.3.2 |
Method A1 | 8.1.1.3.3 |
Method B1 | 8.1.1.3.4 |
Non-Finned Windows in Membrane/Drainage | 8.1.2 |
Windows in Walls Utilizing a Barrier Wall System | 8.2 |
Windows in Walls Utilizing an Exterior Barrier System | 8.3 |
Special Considerations | 8.4 |
Aluminum Framed Windows | 8.4.1 |
Vinyl Framed Windows | 8.4.2 |
Replacement Window Installation | 8.5 |
Partial Window Replacement for Existing Integral | 8.5.1 |
Partial Replacement of Mill Shop Wood Windows | 8.5.2 |
Complete Window Replacement | 8.5.3 |
Destructive Window Replacement (Fin Type) | 8.5.3.1 |
Non-Destructive Window Replacement | 8.5.3.2 |
Installation Methods for Doors | 9 |
Doors in Walls Utilizing a Membrane/Drainage System | 9.1 |
Doors with Perimeter Mounting Flanges | 9.1.1 |
Flange Types | 9.1.1.1 |
Selection of Installation Method | 9.1.1.2 |
Method A | 9.1.1.4.1 |
Method B | 9.1.1.4.2 |
Method A1 | 9.1.1.4.3 |
Method B1 | 9.1.1.4.4 |
Hinged Swing (Non-finned) Doors in Membrane/ | 9.1.2 |
Installation Methods for Skylights | 10 |
Product Types | 10.1 |
Flashing Procedures | 10.2 |
Aluminum/Copper Sheet Flashing | 10.3 |
Aluminum/Copper Step Flashing (Fabricated or | 10.4 |
Membrane Flashing | 10.5 |
Post-Installation Procedures | 11 |
Keywords | 12 |
Air Barrier Foam Sealant Used in the Rough | Annex A1 |
Emergency Escape and Rescue Requirements | Annex A2 |
Minimum Height Requirements for Interior Height of | Annex A3 |
Sealants | Annex A4 |
Window/Door Flashing Types | Appendix X1 |
Cautions for Installation | Appendix X2 |
Bibliography/Other Referenced Installation Guides | Appendix X3 |
ASTM E 2556/E2556M : 2010 : R2016 | Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment |
ASTM E 2110 : 2017 | Standard Terminology for Exterior Insulation and Finish Systems (EIFS) |
ASTM D 4756 : 2015 | Standard Practice for Installation of Rigid Poly(Vinyl Chloride) (PVC) Siding and Soffit |
ASTM E 2266 : 2011 | Standard Guide for Design and Construction of Low-Rise Frame Building Wall Systems to Resist Water Intrusion |
ASTM C 1852 : 2017 | Standard Guide for Product Selection/Delivery Systems for Aerosol Foam Sealants and Adhesives |
ASTM E 241 : 2009 : R2014 : EDT 1 | Standard Guide for Limiting Water-Induced Damage to Buildings |
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ASTM A 123/A123M : 2017 : REDLINE | Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products |
ASTM E 1105 : 2015 : REDLINE | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference |
ASTM B 456 : 2017 : REDLINE | Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus<brk/> Chromium and Nickel Plus Chromium |
ASTM C 1193 : 2016 : REDLINE | Standard Guide for Use of Joint Sealants |
CFR 16(PTS1000-END) : 0 | COMMERCIAL PRACTICES - FEDERAL TRADE COMMISSION - CONSUMER PRODUCT SAFETY COMMISSION |
ASTM C 1382 : 2016 : REDLINE | Standard Test Method for Determining Tensile Adhesion Properties of Sealants When Used in Exterior Insulation and Finish Systems (EIFS) Joints |
ASTM E 331 : 2000 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASTM D 779 : 2016 | Standard Test Method for Determining the Water Vapor Resistance of Sheet Materials in Contact with Liquid Water by the Dry Indicator Method |
ASTM C 834 : 2017 : REDLINE | Standard Specification for Latex Sealants |
ISDI 102 : 1993 | INSTALLATION STANDARD FOR INSULATED STEEL DOOR SYSTEMS |
ASTM C 1311 : 2014 : REDLINE | Standard Specification for Solvent Release Sealants |
CFR 29(PT1910.1000 TO END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
ASTM D 1970/D1970M : 2017-05 | SPECIFICATION FOR SELF-ADHERING POLYMER MODIFIED BITUMINOUS SHEET MATERIALS USED AS STEEP ROOFING UNDERLAYMENT FOR ICE DAM PROTECTION |
ASTM C 1281 : 2016 : REDLINE | Standard Specification for Preformed Tape Sealants for Glazing Applications |
ASTM C 1299 : 2003 | Standard Guide for Use in Selection of Liquid-Applied Sealants (Withdrawn 2012) |
WDMA IS4 : 2015A | INDUSTRY SPECIFICATION FOR PRESERVATIVE TREATMENT FOR MILLWORK |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.