ASTM E 1982 : 1998 : R2021
Current
The latest, up-to-date edition.
Standard Practice for Open-Path Fourier Transform Infrared (OP/FT-IR) Monitoring of Gases and Vapors in Air
Hardcopy , PDF
English
04-22-2021
Committee |
E 13
|
DocumentType |
Standard Practice
|
Pages |
17
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
Supersedes |
1.1This practice covers procedures for using active open-path Fourier transform infrared (OP/FT-IR) monitors to measure the concentrations of gases and vapors in air. Procedures for choosing the instrumental parameters, initially operating the instrument, addressing logistical concerns, making ancillary measurements, selecting the monitoring path, acquiring data, analyzing the data, and performing quality control on the data are given. Because the logistics and data quality objectives of each OP/FT-IR monitoring program will be unique, standardized procedures for measuring the concentrations of specific gases are not explicitly set forth in this practice. Instead, general procedures that are applicable to all IR-active gases and vapors are described. These procedures can be used to develop standard operating procedures for specific OP/FT-IR monitoring applications.
1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this practice to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E 1421 : 1999 : R2021 | Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests |
ASTM E 131 : 2010 : R2023 | Standard Terminology Relating to Molecular Spectroscopy |
ASTM E 168 : 2016 : R2023 | Standard Practices for General Techniques of Infrared Quantitative Analysis |
ASTM E 1421 : 1999 : R2015 : EDT 1 | Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests |
ASTM E 131 : 2010 : R2015 | Standard Terminology Relating to Molecular Spectroscopy |
ASTM E 168 : 2016 | Standard Practices for General Techniques of Infrared Quantitative Analysis |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.