• Shopping Cart
    There are no items in your cart

ASTM E 1940 : 2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Guide for Dosimetry for Sterile Insect Release Programs

Available format(s)

Hardcopy , PDF

Superseded date

09-09-2024

Language(s)

English

Published date

03-21-2014

US$83.00
Excluding Tax where applicable

CONTAINED IN VOL. 12.02, 2001 Covers dosimetric procedures to be followed for the radiation sterilization of live insects for use in pest management programs.

Committee
E 61
DocumentType
Standard
Pages
12
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This guide outlines dosimetric procedures to be followed for the radiation-induced reproductive sterilization of live insects for use in pest management programs. The primary use of such insects is in the Sterile Insect Technique, where large numbers of reproductively sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide.

NOTE 1—Dosimetry is only one component of a total quality assurance program to ensure that irradiated insects are adequately sterilized and fully competitive or otherwise suitable for their intended purpose.

1.2 This guide provides information on dosimetry for the irradiation of insects for these types of irradiators: selfcontained dry-storage 137Cs or 60Co irradiators, self-contained low-energy X-ray irradiators (maximum processing energies from 150 to 300 keV), large-scale gamma irradiators, and electron accelerators (electron and X-ray modes).

NOTE 2—Additional, detailed information on dosimetric procedures to be followed in installation qualification, operational qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities processing at energies over 300 keV), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and 52116 (self-contained dry-storage gamma facilities), and in Ref (1)2 (self-contained X-ray facilities).

1.3 The absorbed dose for insect sterilization is typically within the range of 20 to 600 Gy.

1.4 This guide refers, throughout the text, specifically to reproductive sterilization of insects. It is equally applicable to radiation sterilization of invertebrates from other taxa (for example, Acarina, Gastropoda) and to irradiation of live insects or other invertebrates for other purposes (for example, inducing mutations), provided the absorbed dose is within the range specified in 1.3.

1.5 This guide also covers the use of radiation-sensitive indicators for the visual and qualitative indication that the insects have been irradiated.

1.6 This document is one of a set of standards that provides recommendations for properly implementing and utilizing dosimetry in radiation processing and describes a means of achieving compliance with the requirements of ASTM Practice E2628. It is intended to be read in conjunction with ASTM E2628.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 2116 : 2013 PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR

ASTM E 1275 : 2013 Standard Practice for Use of a Radiochromic Film Dosimetry System
ASTM E 1608 : 2015 Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV
ASTM E 177 : 2014 : REDLINE Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods
ASTM E 1539 : 2005 GUIDE FOR USE OF RADIATION-SENSITIVE INDICATORS
ASTM E 2628 : 2009 Standard Practice for Dosimetry for Radiation Processing
ASTM E 1956 : 2013 Standard Practice for Use of Thermoluminescence-Dosimetry (TLD) Systems for Radiation Processing
ASTM E 1026 : 2015 : REDLINE Standard Practice for Using the Fricke Dosimetry System
ASTM E 2303 : 2011 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
ASTM E 1538 : 2009 PRACTICE FOR USE OF THE ETHANOL-CHLOROBENZENE DOSIMETRY SYSTEM
ASTM E 1607 : 2013 Standard Practice for Use of the Alanine-EPR Dosimetry System
ASTM E 1261 : 2013 GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING
ASTM E 1702 : 2013 PRACTICE FOR DOSIMETRY IN A GAMMA IRRADIATION FACILITY FOR RADIATION PROCESSING
ASTM E 1707 : 2015 Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing
ASTM E 170 : 2017 : REDLINE Standard Terminology Relating to Radiation Measurements and Dosimetry
ASTM E 668 : 2013 : REDLINE Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
ASTM E 1540 : 2004 PRACTICE FOR USE OF A RADIOCHROMIC LIQUID DOSIMETRY SYSTEM
ASTM E 2303 : 2003 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
ASTM E 2303 : 2011 : EDT 1 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
ASTM E 1649 : 2015 Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.