09-07-2017
CONTAINED IN VOL. 04.12, 2017 Defines two techniques for measurement of air leakage rates through a building envelope in buildings configured to a single zone.
Committee |
E 06
|
DocumentType |
Test Method
|
Pages |
13
|
ProductNote |
Reconfirmed 2017
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1These test methods describe two techniques for measuring air leakage rates through a building envelope in buildings that may be configured to a single zone. Both techniques use an orifice blower door to induce pressure differences across the building envelope and to measure those pressure differences and the resulting airflows. The measurements of pressure differences and airflows are used to determine airtightness and other leakage characteristics of the envelope.
1.2These test methods allow testing under depressurization and pressurization.
1.3These test methods are applicable to small indoor-outdoor temperature differentials and low wind pressure conditions; the uncertainty in the measured results increases with increasing wind speeds and temperature differentials.
1.4These test methods do not measure air change rate under normal conditions of weather and building operation. To measure air change rate directly, use Test Method E741.
1.5The text of these test methods reference notes and footnotes that provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 7.
1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 7297 : 2021 | Standard Practice for Evaluating Residential Indoor Air Quality Concerns |
ASTM E 2813 : 2018 | Standard Practice for Building Enclosure Commissioning |
ASTM D 7297 : 2014 | Standard Practice for Evaluating Residential Indoor Air Quality Concerns |
ASTM E 631 : 2015 | Standard Terminology of Building Constructions |
ASTM E 1258 : 1988 : R2018 | Standard Test Method for Airflow Calibration of Fan Pressurization Devices |
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ISO 9972:2015 | Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method |
ASTM E 1258 : 1988 : R2008 | Standard Test Method for Airflow Calibration of Fan Pressurization Devices |
ASTM E 1186 : 2003 | Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems |
ASTM E 456 : 2002 | Standard Terminology for Relating to Quality and Statistics |
ASTM E 1186 : 1998 | Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Retarder Systems |
ASME PTC19.1 : 2013 | TEST UNCERTAINTY |
ASTM E 456 : 2013 : REV A : R2022 | Standard Terminology Relating to Quality and Statistics |
ASTM E 1186 : 2003 : R2009 | Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems |
ASTM E 1258 : 1988 : R1998 | Standard Test Method for Airflow Calibration of Fan Pressurization Devices |
ASTM E 456 : 2013 : REV A : R2017 : EDT 5 | Standard Terminology Relating to Quality and Statistics |
ASTM E 1258 : 1988 : R2003 | Standard Test Method for Airflow Calibration of Fan Pressurization Devices |
ASTM E 1186 : 2017 | Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems |
ASTM E 1186 : 2017 : REDLINE | Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems |
ASTM E 456 : 2013 : REV A : R2017 : EDT 4 | Standard Terminology Relating to Quality and Statistics |
ASTM E 456 : 2013 : REV A : R2017 : EDT 6 | Standard Terminology Relating to Quality and Statistics |
ASTM E 1258 : 1988 : R2012 | Standard Test Method for Airflow Calibration of Fan Pressurization Devices |
ASTM E 1186 : 2022 | Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.