ASTM E 1661 : 1995 : REV A : R1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Classification for Serviceability of an Office Facility for Meetings and Group Effectiveness
Hardcopy , PDF
11-11-2014
English
10-10-1999
CONTAINED IN VOL. 04.11, 2018 Defines pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements to enable work groups or project groups to function effectively and productively.
Committee |
E 06
|
DocumentType |
Standard
|
Pages |
12
|
ProductNote |
Reconfirmed 1999
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This classification contains pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements to enable work groups or project groups to function effectively and productively.
1.2 Within that aspect of serviceability, each pair of scales, shown in Figs. 1 through 4, are for classifying one topic of serviceability. Each paragraph in an Occupant Requirement Scale (see Figs. 1 through 4) summarizes one level of serviceability on that topic, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1 through 4) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability.
1.3 The entries in the Facility Rating Scale (see Figs. 1 through 4) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing.
1.4 This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared.
1.5 This classification indicates what would cause a facility to be rated at a certain level of serviceability but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1334. The scales in this classification are complimentary to and compatible with Practice E1334. Each requires the other.
ASTM E 1765 : 2016 | Standard Practice for Applying Analytical Hierarchy Process (AHP) to Multiattribute Decision Analysis of Investments Related to Projects, Products, and Processes |
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ISO 6240:1980 | Performance standards in building Contents and presentation |
ASHRAE 62 : 2001 | VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY |
ASHRAE 55 : 2017 | THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY |
ASTM E 1679 : 2013 : REDLINE | Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.