• Shopping Cart
    There are no items in your cart

ASTM D 8543 : 2023

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determination of Pesticides and Polychlorinated Biphenyls (PCBs) in Aqueous Solution by a Tandem Gas Chromatography/Mass Spectrometry/Mass Spectrometry (GC/MS/MS)

Available format(s)

Hardcopy , PDF

Superseded date

07-01-2024

Superseded by

ASTM D 8543 : 2024

Language(s)

English

Published date

12-01-2023

US$83.00
Excluding Tax where applicable

Committee
D 19
DocumentType
Test Method
Pages
19
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This test method covers the identification and simultaneous measurement of extractable chlorinated pesticides and polychlorinated biphenyls (PCBs) by gas chromatography/mass spectrometry/mass spectrometry (GC/MS/MS).

1.2This test method has been validated for wastewater influents, effluents, industrial discharges, surface water, and ground water.

1.3This test method is not limited to these particular aqueous matrices; however, the applicability of this test method to other aqueous matrices shall be demonstrated.

1.4This test method is restricted to use by or under the supervision of analysts experienced in the use of a gas chromatograph with tandem mass spectrometry. Each laboratory that uses this test method shall demonstrate the ability to generate results that meet or exceed the performance criteria of this test method.

1.5If sensitivity permits, compound tentative identification of unknowns may be made by analyzing the extract in full-scan mode or, if the system allows simultaneous timed single-reaction monitoring (SRM)/full-scan acquisition. Identify unknown peaks according to Guide D4128.

1.6This test method is performance-based. Minor modifications, as allowed by CFR 40 Part 136.6, may be made to improve the method performance, but changes may not be made to the extraction, the extraction solvent, sample-to-solvent ratio, or the MS/MS detection technique.

1.7Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.

1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.9This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM D 1129 : 2013 : R2020 : EDT 2 Standard Terminology Relating to Water
ASTM D 1129 : 2013 : R2020 : EDT 1 Standard Terminology Relating to Water

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.