ASTM D 5542 : 2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Methods for Trace Anions in High Purity Water by Ion Chromatography
Hardcopy , PDF
11-11-2014
English
06-01-2004
Committee |
D 19
|
DocumentType |
Test Method
|
Pages |
10
|
ProductNote |
Reconfirmed 2004
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 These test methods cover the determination of trace (g/L) levels of fluoride, acetate, formate, chloride, phosphate, and sulfate in high purity water using ion chromatography in combination with sample preconcentration. Other anions, such as bromide, nitrite, nitrate, sulfite, and iodide can be determined by this method. However, since they are rarely present in significant concentrations in high purity water, they are not included in this test method. Two test methods are presented and their ranges of application, as determined by a collaborative study, are as follows:
Range Tested (μg/L Added) | Limit of Detection(Single Operator)(μg/L) | Sections | |
Test Method A: | 7-15 | ||
Chloride | 0-24 | 0.8 | |
Phosphate | 0-39 | ||
Sulfate | 0-55 | 1.8 | |
Test Method B: | 16-22 | ||
Fluoride | 0-14 | 0.7 | |
Acetate | 0-414 | 6.8 | |
Formate | 0-346 | 5.6 |
1.2 It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.
1.3 The common practical range of Test Method A is as follows: chloride, 1 to 100 μg/L, phosphate, 3 to 100 μg/L, and sulfate, 2 to 100 μg/L.
1.4 The common practical range of Test Method B is as follows: fluoride, 1 to 100 μg/L, acetate, 10 to 200 μg/L, and formate, 5 to 200 μg/L.
1.5 The values stated in SI units are to be regarded as the standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 5996 : 2016 | Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography |
ASTM D 8149 : 2017 | Standard Practice for Optimization, Calibration, and Validation of Ion Chromatographic Determination of Heteroatoms and Anions in Petroleum Products and Lubricants |
ASTM D 5196 : 2006 : R2018 | Standard Guide for Bio-Applications Grade Water |
ASTM D 1193 : 2006 : R2018 | Standard Specification for Reagent Water |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.