Standard Test Methods for Continuous Measurement of Oxides of Nitrogen in the Ambient or Workplace Atmosphere by the Chemiluminescent Method
01-21-2021
English
04-01-2012
CONTAINED IN VOL. 11.03, 2017 Defines procedures for the continuous determination of total nitrogen dioxide (NO[2]) and nitric oxide (NO) as NO[x], or nitric oxide (NO) alone or nitrogen dioxide (NO[2]) alone in the ranges.
Committee |
D 22
|
DocumentType |
Redline
|
Pages |
14
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 These test methods cover procedures for the continuous determination of total nitrogen dioxide (NO2) and nitric oxide (NO) as NOx, or nitric oxide (NO) alone or nitrogen dioxide (NO2) alone, in the ranges shown in the following table:
Range of Concentration | ||
Gas | Ambient Atmosphere | Workplace Atmosphere |
μg/m3 (ppm) (Note 1) | mg/m3 (ppm) (Note 1) | |
NO | 10 to 600 (0.01 to 0.5) | 0.6 to 30 (0.5 to 25) |
(NO + NO2) = NOx | 20 to 1000 (0.01 to 0.05) | 1 to 50 (0.5 to 25) |
NO2 | 20 to 1000 (0.01 to 0.5) | 1 to 50 (0.5 to 25) |
Note 1—Approximate range: 25°C and 101.3 kPa (1 atm).
1.2 The test methods are based on the chemiluminescent reaction between nitric oxide and ozone.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 9.
I.S. EN 16738:2015 | EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS |
BS EN 16738:2015 | Emission safety of combustible air fresheners. Test methods |
ASTM B 827:2005 | Standard Practice for Conducting Mixed Flowing Gas (MFG) Environmental Tests |
ASTM B 827 : 2005 : R2009 : EDT 1 | Standard Practice for Conducting Mixed Flowing Gas (MFG) Environmental Tests |
ASTM D 4844 : 2016 : REDLINE | Standard Guide for Air Monitoring at Waste Management Facilities for Worker Protection |
ISO 16000-15:2008 | Indoor air — Part 15: Sampling strategy for nitrogen dioxide (NO2) |
DIN EN ISO 16000-15:2009-04 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
UNI EN ISO 16000-15 : 2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
06/30146336 DC : 0 | EN ISO 16000-15 - INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
ASTM B 827 : 2005 : R2014 | Standard Practice for Conducting Mixed Flowing Gas (MFG) Environmental Tests |
UNE-EN 16738:2016 | Emission safety of combustible air fresheners - Test methods |
EN ISO 16000-15:2008 | Indoor air - Part 15: Sampling strategy for nitrogen dioxide (NO2) (ISO 16000-15:2008) |
DIN EN 16738:2016-04 | EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS |
BS EN ISO 16000-15:2008 | Indoor air Sampling strategy for nitrogen dioxide (NO2) |
I.S. EN ISO 16000-15:2008 | INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO[2]) |
EN 16738:2015 | Emission safety of combustible air fresheners - Test methods |
ASTM B 827 : 2005 : R2009 : EDT 2 | Standard Practice for Conducting Mixed Flowing Gas (MFG) Environmental Tests |
ASTM D 5011 : 2017 : REDLINE | Standard Practices for Calibration of Ozone Monitors Using Transfer Standards |
CFR 40(PTS50-51) : JUL 2017 | PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY |
CFR 40(PTS53-59) : JUL 2017 | PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY |
CFR 29(PT1910.1000 TO END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.