1.1This test method covers procedures for a quantitative accelerated laboratory evaluation of the influence of extraction solutions containing ions leached from thermal insulation on the aqueous corrosion of carbon steel. The primary intent of the practice is for use with thermal insulation and associated materials that contribute to, or alternatively inhibit, the aqueous corrosion of carbon steel due to soluble ions that are leached by water from within the insulation. The quantitative evaluation criteria are Mass Loss Corrosion Rate (MLCR) expressed in mils per year determined from the weight loss due to corrosion of exposed metal coupons after they are cleaned.
1.2This test method cannot cover all possible field conditions that contribute to aqueous corrosion. The intent is to provide an accelerated means to obtain a non-subjective numeric value for judging the potential contribution to the corrosion of carbon steel that can come from ions contained in thermal insulation materials or other experimental solutions. The calculated numeric value is the mass loss corrosion rate. This calculation is based on general corrosion spread equally over the test duration and the exposed area of the experimental cells created for the test. Corrosion found in field situations and this accelerated test also involves pitting, edge effects, and the rate changes over time.
1.3The insulation extraction solutions prepared for use in the test can be altered by the addition of corrosive ions to the solutions to simulate contamination from an external source. Ions expected to provide corrosion inhibition can be added to investigate their inhibitory effect.
1.4Prepared laboratory ionic solutions are used as reference solutions and controls, to provide a means of calibration and comparison.2
1.5Other liquids can be tested for their potential corrosiveness including cooling tower water, boiler feed, and chemical stocks. Added chemical inhibitors or protective coatings applied to the metal can also be evaluated using the general guidelines of the practice.
1.6The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 1728 : 2023 | Standard Specification for Flexible Aerogel Insulation |
ASTM C 991 : 2023 | Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings |
ASTM C 1290 : 2016 : R2021 | Standard Specification for Flexible Fibrous Glass Blanket Insulation Used to Externally Insulate HVAC Ducts |
ASTM C 610 : 2017 : R2023 | Standard Specification for Molded Expanded Perlite Block and Pipe Thermal Insulation |
ASTM C 892 : 2019 | Standard Specification for High-Temperature Fiber Blanket Thermal Insulation |
ASTM C 764 : 2019 | Standard Specification for Mineral Fiber Loose-Fill Thermal Insulation |
ASTM C 1937 : 2024 | Standard Specification for Layered, Glass Fiber Felt Pipe and Board Insulation |
ASTM C 552 : 2022 | Standard Specification for Cellular Glass Thermal Insulation |
ASTM C 592 : 2022 : REV A | Standard Specification for Mineral Fiber Blanket Insulation and Blanket-Type Pipe Insulation (Metal-Mesh Covered) (Industrial Type) |
ASTM C 553 : 2013 : R2019 | Standard Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications |
ASTM C 533 : 2017 : R2023 | Standard Specification for Calcium Silicate Block and Pipe Thermal Insulation |
ASTM C 1071 : 2019 | Standard Specification for Fibrous Glass Duct Lining Insulation (Thermal and Sound Absorbing Material) |
ASTM C 665 : 2023 | Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing |
ASTM C 612 : 2014(R2019) | Standard Specification for Mineral Fiber Block and Board Thermal Insulation |
ASTM C 1902 : 2022 : REV A | Standard Specification for Cellular Glass Insulation Used in Building and Roof Applications |
ASTM C 1696 : 2020 | Standard Guide for Industrial Thermal Insulation Systems |
ASTM C 1393 : 2019 | Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks |
ASTM C 547 : 2022 : REV A | Standard Specification for Mineral Fiber Pipe Insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.