CONTAINED IN VOL. 04.05, 2015 Defines the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.

Committee
C 13
DocumentType
Standard
Pages
3
ProductNote
Reconfirmed 2013
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.

1.1.1These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.

1.2The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are for information only.

Note 1This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 6 psi (14 ft) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.

1.3The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.4.

ASTM C 1821/C1821M : 2016 Standard Practice for Installation of Underground Circular Precast Concrete Manhole Structures

ASTM D 1149 : 2016-02 TEST METHODS FOR RUBBER DETERIORATION - CRACKING IN AN OZONE CONTROLLED ENVIRONMENT
ASTM A 666 : 2015 : REDLINE Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar
ASTM D 543 : 2014 : REDLINE Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents
ASTM C 913 : 2016-07 SPECIFICATION FOR PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES
ASTM A 493 : 2016 : REDLINE Standard Specification for Stainless Steel Wire and Wire Rods for Cold Heading and Cold Forging
ASTM D 1566 : 2015 : REDLINE TERMINOLOGY RELATING TO RUBBER
ASTM D 471 : 2016-02 TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS