ASTM C 1029 : 2015 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation
01-07-2021
English
05-15-2015
CONTAINED IN VOL. 04.06, 2015 Defines the types and physical properties of spray applied rigid cellular polyurethane intended for use as thermal insulation.
Committee |
C 16
|
DocumentType |
Redline
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This specification covers the types and physical properties of spray applied rigid cellular polyurethane intended for use as thermal insulation. The operating temperatures of the surfaces to which the insulation is applied shall not be lower than −22°F (−30°C) or greater than +225°F (+107°C). For specific applications, the actual temperature limits shall be as agreed upon between the manufacturer and the purchaser.
1.2The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 6705 : 2004 | Standard Guide for the Repair and Recoat of Sprayed Polyurethane Foam Roofing Systems |
ASTM C 1774 : 2013 | Standard Guide for Thermal Performance Testing of Cryogenic Insulation Systems |
NFPA 5000 : 2018 | BUILDING CONSTRUCTION AND SAFETY CODE |
ICC 2009 INT. RESI.CODE & COMM.-I1 : 2009 | 2009 INTERNATIONAL RESIDENTIAL CODE & COMMENTARY - VOLUME 2: CHAPTERS 12 TO 44 |
A-A-59183 Base Document:1998 | ICEMAKER-DISPENSER WITH WATER DISPENSER ATTACHMENT (NAVAL SHIPBOARD) |
A-A-59190 Base Document:1998 | Cold Food Counter, Mechanically Refrigerated (Naval Shipboard) |
ICC IBC INTERNATIONAL BUILDING CODE : 2015 | INTERNATIONAL BUILDING CODE |
ICC 2012 INTERNATIONAL BUILDING CODE : 2012 | INTERNATIONAL BUILDING CODE |
ASTM D 6705/D6705M : 2004 : R2018 | Standard Guide for Repair and Recoat of Spray Polyurethane Foam Roofing Systems |
ASTM D 7119 : 2007 | Standard Guide for Sampling Spray Polyurethane Foam and Coating in Roofing |
NACE RP 01 98 : 2004 | THE CONTROL OF CORROSION UNDER THERMAL INSULATION AND FIREPROOFING MATERIALS - A SYSTEMS APPROACH |
ASTM C 1696 : 2016 : REDLINE | Standard Guide for Industrial Thermal Insulation Systems |
ASTM D 5469/D5469M : 2012 : REDLINE | Standard Guide for Application of New Spray Applied Polyurethane Foam and Coated Roofing Systems |
ICC IRC CODE AND COMMENTARY VOLUME 2 : 2015 | IRC® Code and Commentary, Volume 2 |
ICC 2012 INTERNATIONAL RESI. CODE : 2012 | INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO-FAMILY DWELLINGS |
ASTM D 5469 : 2000 : R2005 | Standard Guide for Application of New Spray Applied Polyurethane Foam and Coated Roofing Systems |
ASTM D 5469 : 2000 | Standard Guide for Application of New Spray Applied Polyurethane Foam and Coated Roofing Systems |
ASTM D 6705/D6705M : 2004 : R2011 : EDT 1 | Standard Guide for the Repair and Recoat of Sprayed Polyurethane Foam Roofing Systems |
NACE SP 01 98 : 2016 | CONTROL OF CORROSION UNDER THERMAL INSULATION AND FIREPROOFING MATERIALS - A SYSTEMS APPROACH |
ASTM E 96/E96M : 2016 : REDLINE | Standard Test Methods for Water Vapor Transmission of Materials |
ASTM C 518 : 2017 : REDLINE | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM D 1623 : 2017 : REDLINE | Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics |
ASTM D 1622/D1622M : 2014 : REDLINE | Standard Test Method for Apparent Density of Rigid Cellular Plastics |
ASTM C 1363 : 2011 : REDLINE | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM D 6226 : 2015 : REDLINE | Standard Test Method for Open Cell Content of Rigid Cellular Plastics |
ASTM D 2126 : 2015 : REDLINE | Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging |
ASTM D 1621 : 2016 : REDLINE | Standard Test Method for Compressive Properties of Rigid Cellular Plastics |
ASTM C 168 : 2017-06 | TERMINOLOGY RELATING TO THERMAL INSULATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.