1.1 This specification covers the types and physical properties of spray applied rigid cellular polyurethane intended for use as thermal insulation.
Committee |
C 16
|
DocumentType |
Standard
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This specification covers the types and physical properties of spray applied rigid cellular polyurethane intended for use as thermal insulation. The operating temperatures of the surfaces to which the insulation is applied shall not be lower than −22°F (−30°C) or greater than +225°F (+107°C). For specific applications, the actual temperature limits shall be as agreed upon between the manufacturer and the purchaser.
1.2The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM C 1774 : 2013 | Standard Guide for Thermal Performance Testing of Cryogenic Insulation Systems |
ASTM C 1696 : 2016 | Standard Guide for Industrial Thermal Insulation Systems |
ASTM D 7119/D7119M : 2013 : REV A | Standard Guide for Sampling Spray Polyurethane Foam and Coating in Roofing |
ASTM D 5469/D5469M : 2012 | Standard Guide for Application of New Spray Applied Polyurethane Foam and Coated Roofing Systems (Withdrawn 2021) |
ASTM D 6705/D6705M : 2004 : R2018 | Standard Guide for Repair and Recoat of Spray Polyurethane Foam Roofing Systems |
ASTM C 1558 : 2019 | Standard Guide for Development of Standard Data Records for Computerization of Thermal Transmission Test Data for Thermal Insulation |
ASTM D 2126 : 1999 | Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging |
ASTM D 2126 : 2004 | Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging |
ASTM D 2842 : 2001 | Standard Test Method for Water Absorption of Rigid Cellular Plastics |
ASTM D 1621 : 2010 | Standard Test Method for Compressive Properties Of Rigid Cellular Plastics |
ASTM C 1363 : 2019 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 1363 : 2005 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 1363 : 1997 | Standard Test Method for the Thermal Performance of Building Assemblies by Means of a Hot Box Apparatus |
ASTM D 2126 : 2015 | Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging |
ASTM D 1621 : 2016 | Standard Test Method for Compressive Properties of Rigid Cellular Plastics |
ASTM D 1621 : 2004 | Standard Test Method for Compressive Properties Of Rigid Cellular Plastics |
ASTM D 1623 : 2003 | Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics |
ASTM D 6226 : 2005 | Standard Test Method for Open Cell Content of Rigid Cellular Plastics |
ASTM D 6226 : 1998 : EDT 1 | Standard Test Method for Open Cell Content of Rigid Cellular Plastics |
ASTM D 1621 : 2004 : REV A | Standard Test Method for Compressive Properties Of Rigid Cellular Plastics |
ASTM D 2842 : 2012 | Standard Test Method for Water Absorption of Rigid Cellular Plastics |
ASTM D 2842 : 1997 | Standard Test Method for Water Absorption of Rigid Cellular Plastics |
ASTM D 1623 : 2009 | Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics |
ASTM C 1363 : 2011 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM D 1623 : 1978 : R1995 | Standard Test Method for Tensile And Tensile Adhesion Properties Of Rigid Cellular Plastics |
ASTM D 1621 : 2000 | Standard Test Method for Compressive Properties Of Rigid Cellular Plastics |
ASTM D 1621 : 1994 | Standard Test Method for Compressive Properties of Rigid Cellular Plastics |
ASTM D 2842 : 2019 | Standard Test Method for Water Absorption of Rigid Cellular Plastics |
ASTM D 2126 : 2009 | Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging |
ASTM D 6226 : 2015 | Standard Test Method for Open Cell Content of Rigid Cellular Plastics |
ASTM D 6226 : 2010 | Standard Test Method for Open Cell Content of Rigid Cellular Plastics |
ASTM D 1623 : 2017 | Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics |
ASTM D 2842 : 2006 | Standard Test Method for Water Absorption of Rigid Cellular Plastics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.