The objective of this Standard is to specify procedures for on-site measurement of flat-plate photovoltaic (PV) array characteristics, the accompanying meteorological conditions, and use of these for translating to standard test conditions (STC) or other selected conditions.
Committee |
EL-042
|
DocumentType |
Standard
|
ISBN |
978 1 76072 797 0
|
Pages |
12
|
PublisherName |
Standards Australia
|
Status |
Current
|
This International Standard specifies procedures for on-site measurement of flat-plate photovoltaic (PV) array characteristics, the accompanying meteorological conditions, and use of these for translating to standard test conditions (STC) or other selected conditions.
Measurements of PV array current-voltage (I-V) characteristics under actual on-site conditions and their translation to reference test conditions (RTC) can provide:
- data for power rating or capacity testing;
- verification of installed array power performance relative to design specifications;
- detection of possible differences between on-site module characteristics and laboratory or factory measurements;
- detection of possible performance degradation of modules and arrays with respect to onsite initial data;
- detection of possible module or array failures or poor performance.
For a particular module, on-site measurements translated to STC can be directly compared with results previously obtained in a laboratory or factory for that module. Corrections for differences in the spectral or spatial response of the reference devices may need to be assessed as specified in IEC 60904.
On-site array measurements are affected by diode, cable, and mismatch losses, soiling and shading, degradation due to aging, and other uncontrolled effects. Therefore, they are not expected to be equal to the product of the number of modules and the respective module data.
If a PV array is formed with sub-arrays of different tilt, orientation, technology, or electrical configuration, the procedure specified in this International Standard is applied to each unique PV sub-array of interest.
Standards | Relationship |
IEC 61829:2015 | Identical |
First published as AS/NZS IEC 61829:2020.
IEC 60904-3:2016 | Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data |
IEC 60904-2:2015 | Photovoltaic devices - Part 2: Requirements for photovoltaic reference devices |
IEC 61853-1:2011 | Photovoltaic (PV) module performance testing and energy rating - Part 1: Irradiance and temperature performance measurements and power rating |
IEC 60904-1:2006 | Photovoltaic devices - Part 1: Measurement of photovoltaic current-voltage characteristics |
IEC 60904-7:2008 | Photovoltaic devices - Part 7: Computation of the spectral mismatch correction for measurements of photovoltaic devices |
IEC 60904-5:2011 | Photovoltaic devices - Part 5: Determination of the equivalent cell temperature (ECT) of photovoltaic (PV) devices by the open-circuit voltage method |
IEC 60904-4:2009 | Photovoltaic devices - Part 4: Reference solar devices - Procedures for establishing calibration traceability |
IEC 60904-10:2009 | Photovoltaic devices - Part 10: Methods of linearity measurement |
ISO/IEC 17025:2017 | General requirements for the competence of testing and calibration laboratories |
IEC 60891:2009 | Photovoltaic devices - Procedures for temperature and irradiance corrections to measured I-V characteristics |