• There are no items in your cart

AS/NZS 61347.1:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Lamp controlgear General and safety requirements (IEC 61347-1:2000, MOD)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

07-29-2024

Superseded by

AS/NZS 61347.1:2016

Language(s)

English

Published date

08-27-2002

Preview
US$86.40
Excluding Tax where applicable

Specifies electrical safety requirements for lamp controlgear for use in d.c. supplies up to 250 volt and a.c. supplies up to 1000 V. This Standard is reproduced from IEC 61347-1:2000 and varied to suit Australian/New Zealand conditions.

Committee
EL-041
DocumentType
Standard
ISBN
0 7337 4774 4
Pages
50
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This part of AS/NZS 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.This standard also covers lamp controlgear for lamps which are not yet standardized.Tests dealt with in this standard are type tests. Requirements for testing individual lamp controlgear during production are not included.Requirements for semi-luminaires are given in AS/NZS 60598.1.In addition to the requirements given in this standard, annex B sets out general and safety requirements applicable to thermally protected lamp controlgear.Annex C sets out additional general and safety requirements as they apply to electronic lamp controlgear with means of protection against overheating.NOTE – Examples of products covered by this Standard are electronic starters, ballasts and electronic converters. Dimmers, iron core transformers (if not covered by 61347.2) are not included in this Standard.

First published as AS/NZS 61347.1:2002.

AS/NZS 60598.1:2001 Luminaires General requirements and tests (IEC 60598.1:1996, MOD)
AS/NZS 60695.2.10:2001 Glowing/hot wire based test methods Glow-wire apparatus and common test procedure
AS/NZS 60921:2002 Ballasts for tubular fluorescent lamps - Performance requirements (Reconfirmed 2019)
AS/NZS 4695.2.2:1996 Fire hazard testing of electrotechnical products Test methods - Needle-flame test

AS/NZS 1158.6:2010 Lighting for roads and public spaces Luminaires
AS/NZS IEC 61347.2.13:2013 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules (IEC 61347-2-13, Ed.1.0 (2006) MOD)
AS/NZS 60929:2005 A.C. supplied electronic ballasts for tubular fluorescent lamps - Performance requirements (Reconfirmed 2016)
AS/NZS 61347.2.5:2002 Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for public transport
AS/NZS 61347.2.10:2004 Lamp controlgear Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes) (IEC 61347-2-10:2000 MOD)
AS/NZS 61347.2.6:2002 Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for aircraft lighting
AS/NZS 61347.2.2:2004 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2:2000 MOD)
AS/NZS 4879.2:2010 Performance of transformers and electronic step-down convertors for ELV lamps Minimum Energy Performance Standards (MEPS) requirements (Reconfirmed 2020)
AS/NZS 4879.2(INT):2008 Performance of transformers and electronic step-down convertors for ELV lamps Minimum Energy Performance Standards (MEPS) requirements
AS/NZS 60598.2.22:2005 Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2 22, Ed. 3.1(2002) MOD)
AS/NZS 4879.1:2008 Performance of transformers and electronic step-down convertors for ELV lamps Test method - Energy performance (Reconfirmed 2017)
AS/NZS 61347.2.9:2004 Lamp controlgear Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) (IEC 61347-2-9:2000 MOD)
AS/NZS 60925:2005 D.C. supplied electronic ballasts for tubular fluorescent lamps - Performance requirements (IEC 60925, Ed. 1.2 (2001) MOD)
AS/NZS 61347.2.11:2003 Lamp controlgear Particular requirements for miscellaneous electronic circuits used with luminaires (IEC 61347-2-11:2001 MOD) (Reconfirmed 2016)
AS/NZS 61347.2.8:2003 Lamp controlgear Particular requirements for ballasts for fluorescent lamps (IEC 61347-2-8:2000, MOD) (Reconfirmed 2019)
AS/NZS 61347.2.2:2007 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2, Ed. 1.2 (2006) MOD)
AS/NZS 61347.2.3:2004 Lamp controlgear Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps (IEC 61347-2-3:2000, MOD)
AS/NZS 60927:2005 Auxiliaries for lamps - Starting devices (other than glow starters) - Performance requirements (IEC 60927, Ed.2.2 (2004) MOD)
AS/NZS 1158.6:2004 Lighting for roads and public spaces Luminaires
AS/NZS 61347.2.1:2002 Lamp controlgear Particular requirements for starting devices (other than glow starters)
AS/NZS 60598.1:2003 Luminaires General requirements and tests (IEC 60598-1:2003, MOD)
AS/NZS 61347.2.4:2002 Lamp controlgear Particular requirements for d.c. supplied electronic ballasts for general lighting

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.