AS/NZS 61008.1:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Residual current operated circuit breakers without integral overcurrent protection for household and similar uses (RCCBs) General rules (IEC 61008-1, Ed. 2.1 (2002) MOD)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
06-30-2017
English
08-13-2004
Proposes the adoption of IEC 61008-1:2002 as a revision of AS/NZS 3175:1994. Contains essential safety and associated requirements for residual current operated circuit-breakers for household and similar uses, not incorporating overcurrent protection, for rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A. Annex ZZ lists variations for Australian and New Zealand conditions.
Committee |
EL-004
|
DocumentType |
Standard
|
ISBN |
0 7337 4758 2
|
Pages |
112
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This International Standard applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCBs), for rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A, intended principally for protection against shock-hazard. These devices are intended to protect persons against indirect contact, the exposed conductive parts of the installation being connected to an appropriate earth electrode. They may be used to provide protection against fire hazards due to a persistent earth fault current, without the operation of the overcurrent protective device. RCCBs having a rated residual operating current not exceeding 30 mA are also used as a means for additional protection in case of failure of the protective means against electric shock. This standard applies to devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. NOTE 1 The requirements for RCCBs are in line with the general requirements of IEC 60755. RCCBs are essentially intended to be operated by uninstructed persons and designed not to require maintenance. They may be submitted for certification purposes. NOTE 2 Installation and application rules of RCCBs are given in IEC 60364. NOTE 3 RCCBs within the scope of the present standard are considered as suitable for isolation (see 8.1.3). NOTE 201 The adoption of IEC Standards for portable and socket-outlet devices is under consideration. However, until they are published, this Standard and AS/NZS 3112, for socket-outlet devices, and this Standard and AS 3190, for portable devices, may be used by testing to selected clauses. Special precautions (e.g. lightning arresters) may be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines) (see IEC 60364-4-443). RCCBs of the general type are resistant to unwanted tripping including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCCBs of the S type are considered to be sufficient proof against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. NOTE 4 Surge arresters installed downstream of the general type of RCCBs and connected in common mode may cause unwanted tripping. NOTE 5 For RCCBs having a degree of protection higher than IP20 special constructions may be required. Particular requirements are necessary for – Residual current operated circuit-breakers with integral overcurrent protection (see IEC 61009); – RCCBs incorporated in or intended only for association with plugs and socket-outlets or with appliance couplers for household or similar general purposes. NOTE 6 For the time being, for RCCBs incorporated in, or intended only for socket-outlets or plugs, the requirements of this standard in conjunction with the requirements of IEC 60884-1 may be used as far as applicable. The requirements of this standard apply for normal environmental conditions (see 7.1). Additional requirements may be necessary for RCCBs used in locations having severe environmental conditions. RCCBs including batteries are not covered by this standard.
First published as AS/NZS 3175.1:1994.
Jointly revised and redesignated as AS/NZS 61008.1:2004.
AS/NZS 60695.2.10:2001 | Glowing/hot wire based test methods Glow-wire apparatus and common test procedure |
AS 60529-2004 | Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018) |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 1104-1978 | Informative symbols for use on electrical and electronic equipment |
AS/NZS 3112:2000 | Approval and test specification - Plugs and socket-outlets |
AS 1931.2-1996 | High-voltage test techniques - Measuring systems |
AS 60038-2000 | Standard voltages |
AS 60068.2.30-2003 | Environmental testing Tests - Test Db and guidance: Damp heat, cyclic (12 + 12-hour cycle) |
AS 1852.151-1988 | International electrotechnical vocabulary - Electric and magnetic devices |
AS 1852.441-1985 | International electrotechnical vocabulary - Switchgear, controlgear and fuses |
AS/NZS 61009.1:2004 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 2.1 (2003) MOD) |
AS 60068.3.4-2003 | Environmental testing Supporting documentation and guidance - Damp heat tests |
AS/NZS 3012:2010 | Electrical installations - Construction and demolition sites |
AS/NZS 5761:2011 | In-service safety inspection and testing - Second-hand equipment prior to sale |
AS/NZS 4836:2011 | Safe working on or near low-voltage electrical installations and equipment |
AS/NZS 60745.1:2009 | Hand-held motor-operated electric tools-Safety General requirements (IEC 60745-1 Ed 4, MOD) (Reconfirmed 2020) |
AS/NZS 5033:2005 | Installation of photovoltaic (PV) arrays |
AS/NZS 5762:2011 | In-service safety inspection and testing - Repaired electrical equipment |
AS/NZS 3003:2011 | Electrical installations - Patient areas |
AS/NZS 3190:2009 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS 62103-2006 | Electronic equipment for use in power installations |
AS/NZS 61009.1:2004 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 2.1 (2003) MOD) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 4763(INT):2006 | Safety of Portable Inverters |
AS/NZS 3760:2010 | In-service safety inspection and testing of electrical equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.