AS/NZS 60137:2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

05-15-2020

Superseded by

AS/NZS 60137:2020

Language(s)

English

Published date

06-19-2008

Preview
US$99.38
Excluding Tax where applicable

1 - AS/NZS 60137:2008 Insulated bushings for alternating voltages above 1000 V
4 - PREFACE
5 - CONTENTS
7 - INTRODUCTION
9 - 1 Scope
9 - 2 Normative references
11 - 3 Terms and definitions
16 - 4 Ratings
16 - 4.1 Standard values of highest voltage for equipment (Um)
16 - 4.2 Standard values of rated current (Ir)
17 - 4.3 Standard values of rated thermal short-time current (Ith)
17 - 4.4 Standard values of rated dynamic current (Id)
17 - 4.5 Minimum withstand values of cantilever load
17 - 4.6 Angle of mounting
17 - 4.7 Minimum nominal creepage distance
18 - 4.8 Temperature limits and temperature rise
18 - 4.9 Standard insulation levels
19 - 4.10 Test tap on transformer bushings
19 - 5 Operating conditions
19 - 5.1 Temporary overvoltages
19 - 5.2 Altitude
20 - 5.3 Temperature of ambient air and immersion media
20 - 5.4 Seismic conditions
20 - 6 Ordering information and markings
20 - 6.1 Enumeration of characteristics
22 - 6.2 Markings
22 - 7 Test requirements
22 - 7.1 General requirements
23 - 7.2 Test classification
24 - 7.3 Condition of bushings during dielectric and thermal tests
24 - 8 Type tests
25 - 8.1 Dry or wet power-frequency voltage withstand test
25 - 8.2 Dry lightning impulse voltage withstand test (BIL)
26 - 8.3 Dry or wet switching impulse voltage withstand test (SIL)
27 - 8.4 Thermal stability test
28 - 8.5 Temperature rise test
30 - 8.6 Verification of thermal short-time current withstand
31 - 8.7 Cantilever load withstand test
32 - 8.8 Tightness test on liquid-filled, compound-filled and liquid-insulated bushings
32 - 8.9 Internal pressure test on gas-filled, gas-insulated and gas-impregnated bushings
32 - 8.10 External pressure test on partly or completely gas-immersed bushings
33 - 8.11 Verification of dimensions
33 - 9 Routine tests
33 - 9.1 Measurement of dielectric dissipation factor (tan δ) and capacitance at ambient temperature
34 - 9.2 Dry lightning impulse voltage withstand test (BIL)
34 - 9.3 Dry power-frequency voltage withstand test
35 - 9.4 Measurement of partial discharge quantity
35 - 9.5 Tests of tap insulation
36 - 9.6 Internal pressure test on gas-filled, gas-insulated and gas-impregnated bushings
36 - 9.7 Tightness test on liquid-filled, compound-filled and liquid-insulated bushings
36 - 9.8 Tightness test on gas-filled, gas-insulated and gas-impregnated bushings
37 - 9.9 Tightness test at the flange or other fixing device
38 - 9.10 Visual inspection and dimensional check
38 - 10 Requirements and tests for bushings of highest voltages for equipment equal to or less than 52 kV made of ceramic, glass or inorganic materials, resin or combined insulation
38 - 10.1 Temperature requirements
38 - 10.2 Level of immersion medium
38 - 10.3 Markings
39 - 10.4 Test requirements
50 - Bibliography
51 - Annex ZA (normative) Radio influence voltage (RIV) test
52 - Annex ZZ (normative) Variations to IEC 60137, Ed. 5.0 (2003) for application in Australia and New Zealand
55 - Annex ZA (normative) Radio influence voltage (RIV) test

Specifies the characteristics and tests for insulated bushings for electrical equipment with a voltage above 1000 volt a.c. and a nominal frequency in the range 15-60 Hz.

Committee
EL-008
DocumentType
Standard
ISBN
0 7337 8713 4
Pages
47
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Originated as AS 1265-1990.
Jointly revised and redesignated as AS/NZS 60137:2008.

AS 60038-2000 Standard voltages
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 60270-2001 High-voltage test techniques - Partial discharge measurements (Reconfirmed 2015)
AS 2374.5-1982 Power Transformers Ability To Withstand Short-Circuit
AS 1824.1-1995 Insulation co-ordination Definitions, principles and rules
AS/NZS 1052:1992 CISPR specification for radio interference measuring apparatus and measurement methods
AS 3768-1990 Guide to the effects of temperature on electrical equipment
AS 2650-2005 Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD)
AS 60068.2.17-2003 Environmental testing Tests - Test Q: Sealing
AS IEC 62155-2005 Insulators - Ceramic or glass - Hollow pressurized and unpressurized - Voltages greater than 1000 V a.c. (Reconfirmed 2016)
AS 2374.7-1997 Power transformers Loading guide for oil-immersed power transformers
AS 4436-1996 Guide for the selection of insulators in respect of polluted conditions

AS/NZS 60076.1:2014 Power transformers General (IEC 60076-1, Ed. 3.0 (2011) MOD)
AS/NZS 60076.6:2013 Power transformers Reactors
AS 62271.203-2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.