• Shopping Cart
    There are no items in your cart

AS/NZS 60079.5:2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Explosive atmospheres Equipment protection by powdered filling 'q'

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

08-17-2023

Superseded by

AS/NZS 60079.5:2015

Language(s)

English

Published date

07-31-2007

Preview
US$86.69
Excluding Tax where applicable

1 - AS/NZS 60079.5:2007 Explosive atmospheres Part 5: Equipment protection by powdered filling 'q'
4 - PREFACE
5 - 1 Scope
5 - 2 Normative references
6 - 3 Terms and definitions
6 - 4 Constructional requirements
6 - 4.1 Enclosure
7 - 4.2 Filling material
8 - 4.3 Distances
9 - 4.4 Materials used for support of energized parts
9 - 4.5 External field-wiring connections
9 - 4.6 Capacitors
9 - 4.7 Cells and batteries
10 - 4.8 Temperature limitations
10 - 4.9 Temperature limitations under fault conditions
13 - 5 Verifications and tests
13 - 5.1 Type verifications and tests
14 - 5.2 Routine verifications and tests
15 - 6 Marking
15 - 7 Instructions
17 - Annex A (informative) Introduction of an alternative risk assessment method encompassing “equipment protection levels” for Ex equipment
22 - Bibliography

Contains the specific requirements for the construction, testing and marking of electrical apparatus, parts of electrical apparatus and Ex components in the type of protection powder filling 'q', intended for use in potentially explosive atmospheres of gas, vapour and mist.

Committee
EL-014
DocumentType
Standard
ISBN
0 7337 8282 5
Pages
18
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC 60079-5:2007 Identical

First published as AS/NZS 60079.5:2000.
Second edition 2007.

AS/NZS 60079.0:2005 Electrical apparatus for explosive gas atmospheres General requirements
AS 60529-2004 Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018)

AS 4647-2011 Diaphragm gas meters
AS/NZS 60335.2.11:2009 Household and similar electrical appliances - Safety Particular requirements for tumble dryers (IEC 60335-2-11 Ed 7.1, MOD)
AS/NZS 3800:2012 Electrical equipment for explosive atmospheres - Repair and overhaul
AS/NZS 60079.0:2008 Explosive atmospheres Equipment - General requirements
AS/NZS 60079.33:2012 Explosive atmospheres Equipment protection by special protection 's' (Reconfirmed 2024)
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 60079.0:2012 Explosive atmospheres Equipment - General requirements
AS/NZS 2290.1:2014 Electrical equipment for coal mines - Introduction, inspection and maintenance For hazardous areas
HB 239:2011 Guidance on the repair and overhaul of electrical equipment for explosive atmospheres
AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements
AS/NZS 5026:2012 The storage and handling of Class 4 dangerous goods (Reconfirmed 2024)
HB 13-2007 Electrical equipment for hazardous areas
AS ISO 21789:2014 Gas turbine applications - Safety
AS/NZS 4871.3:2010 Electrical equipment for mines and quarries Substations
AS/NZS 60079.14:2009 Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.