AS/NZS 5000.1:2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

05-23-2024

Superseded by

AS/NZS 5000.1:2005

Language(s)

English

Published date

11-28-2003

Preview
US$72.80
Excluding Tax where applicable

1 - AS/NZS 5000.1:2003 ELECTRIC CABLES-POLYMERIC INSULATED - FOR WORKING VOLTAGES UP TO AND INCLUDING 0.6/1 (1.2) KV
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 REFERENCED DOCUMENTS
7 - 3 DEFINITIONS
7 - 3.1 Aerial cables
7 - 3.2 Approximate value
7 - 3.3 Core (of a cable)
7 - 3.4 Direction of lay
7 - 3.5 Fictitious values
7 - 3.6 Fixed cable
7 - 3.7 Flexible cable
7 - 3.8 Multicore cable
7 - 3.9 Non-hygroscopic material
7 - 3.10 Pitch circle diameter
7 - 3.11 Routine tests
7 - 3.12 Sample tests
8 - 3.13 Shall
8 - 3.14 Should
8 - 3.15 Type tests
8 - 3.16 Voltage designation
8 - 3.17 Wavelength or length of lay
8 - 4 VOLTAGE DESIGNATION
8 - 5 CONDUCTORS
9 - 6 INSULATION
9 - 6.1 Material
9 - 6.1.1 General
9 - 6.1.2 Aerial cables or fixed cables used in outdoor applications
9 - 6.2 Application
9 - 6.3 Thickness
10 - 6.4 Core identification
10 - 6.4.1 Restricted colours
10 - 6.4.2 Method
11 - 6.4.3 Colours
11 - 6.4.4 Figures and words
11 - 7 ASSEMBLY OF CORES
11 - 7.1 Flat cables
11 - 7.2 Circular cables
11 - 7.2.1 Lay-up of cores
11 - 7.2.2 Fillers, barrier tapes and binders
12 - 8 BEDDING (OPTIONAL)
12 - 8.1 General
12 - 8.2 Material
12 - 8.3 Application
12 - 8.3.1 Taped bedding
12 - 8.3.2 Extruded bedding
12 - 8.4 Thickness
12 - 8.4.1 General
12 - 8.4.2 Reduced thickness taped bedding under a metallic screen or concentric conductor
13 - 9 METALLIC LAYERS (OPTIONAL)
13 - 10 SEPARATION LAYER (OPTIONAL)
13 - 10.1 General
13 - 10.2 Material and application
13 - 10.3 Thickness
14 - 11 ARMOUR (OPTIONAL)
14 - 11.1 Material
14 - 11.2 Dimensions of wire and tape
14 - 11.3 Application
14 - 11.3.1 General
14 - 11.3.2 Wire armour
15 - 11.3.3 Tape armour
15 - 11.4 Further protection
15 - 12 METALLIC SHEATH (OPTIONAL)
15 - 12.1 Material
15 - 12.2 Application
15 - 12.3 Thickness
15 - 12.4 Further protection
15 - 13 NON-METALLIC SHEATH (OPTIONAL)
15 - 13.1 General
16 - 13.2 Material
16 - 13.3 Application
16 - 13.4 Thickness
16 - 13.4.1 Average thickness
17 - 13.4.2 Minimum thickness
17 - 13.4.3 Thickness of combined layer
17 - 14 NON-METALLIC BRAID (OPTIONAL)
17 - 14.1 Material and application
18 - 14.2 Thickness
18 - 15 FURTHER PROTECTION (OPTIONAL)
18 - 16 MARKING
18 - 16.1 Information to be marked
18 - 16.2 Means of marking
19 - 16.3 Marking of packaging
19 - 17 TESTS
22 - APPENDIX A - PURCHASING GUIDELINES
22 - A1 GENERAL
22 - A2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
23 - APPENDIX B - THE FICTITIOUS CALCULATION METHOD FOR THE DETERMINATION OF THE DIMENSIONS OF PROTECTIVE COVERINGS
23 - B1 INTRODUCTION
23 - B2 GENERAL
23 - B3 METHOD
23 - B3.1 Conductors
24 - B3.2 Cores
24 - B3.3 Diameter over laid-up cores
26 - B3.4 Bedding
27 - B3.5 Metallic screen or concentric conductor
27 - B3.6 Metallic sheath
27 - B3.7 Separation layer
27 - B3.8 Armour
28 - B3.9 Non-metallic sheath

Specifies the construction, dimensions and test requirements for cables insulated with polymeric materials intended for use in electrical installations at working voltages up to and including 0.6/1 (1.2) kV. It does not apply to polymeric insulated cables for special installations for which there are separate Australian/New Zealand Standards, e.g. flexible lift control cables, neutral screened cables, welding cables, flexible cords and aerial bundled cables.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 5571 2
Pages
23
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies construction, dimensions and tests for single and multicore cables insulated with polymeric materials intended for use in electrical installations at working voltages up to and including 0.6/1 (1.2) kV. It does not apply to polymeric insulated cables for special installations and service conditions or for which there are separate Australian/New Zealand Standards, e.g. flexible lift control cables, neutral screened cables, welding cables, flexible cords and aerial bundled cables. NOTES: 1 Purchasing guidelines are contained in Appendix A. 2 AS/NZS 3008.1 should be referenced to assist correct cable size selection for the intended application and installation.

First published in Australia in part as AS 4802.3-1991.
AS 4802.3 Supplement 1 first published 1991.
AS 4802.3 Supplement 2 first published 1992.
First published in New Zealand as NZS/ISO/IEC 8802-3:1990.
AS 4802.3-1991, AS 4802.3 Supplement 1-1991, AS 4802.3 Supplement 2-1992 and NZS/ISO/IEC 8802-3:1990, jointly revised, amalgamated and designated as Joint Standard AS/NZS 4802.3:1994.

AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017)
AS/NZS 1660.2.2:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to elastomeric, XLPE and XLPVC materials (Reconfirmed 2017)
AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables (Reconfirmed 2017)
AS/NZS 3560.2:2003 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors
AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
AS/NZS 1660.2.3:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to PVC and halogen free thermoplastic materials (Reconfirmed 2017)
AS/NZS 4507:1998 Cables - Fire performance
AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)
AS/NZS 1660.3:1998 Test methods for electric cables, cords and conductors Electrical tests (Reconfirmed 2017)
AS/NZS 3008.1.1:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 2893:2002 Electric cables - Lead and lead alloy sheaths - Composition
AS/NZS 1660.1:1998 Test methods for electric cables, cords and conductors Conductors and metallic components (Reconfirmed 2017)
AS/NZS 3863:2002 Galvanized mild steel wire for armouring of cables
AS 2706-1984 Numerical values - Rounding and interpretation of limiting values
AS/NZS 1660.5.6:1998 Test methods for electric cables, cords and conductors Fire tests - Test for combustion propagation
AS/NZS 1660.2.1:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application (Reconfirmed 2017)

AS/NZS 3015:2004 Electrical installations - Extra-low voltage d.c. power supplies and service earthing within public telecommunications networks
AS 2402.1.1-2005 Traction batteries - Lead-acid Vented cells - Requirements (Reconfirmed 2021)
AS 2832.1-2004 Cathodic protection of metals Pipes and cables
AS 1530.4-2005 Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction
AS/NZS 3123:2005 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016)
AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements
AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
AS/NZS 1768(INT):2003 Lightning protection
AS 2402.2.1-2005 Traction batteries - Lead-acid Valve-regulated cells - Requirements (Reconfirmed 2021)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.