AS/NZS 3666.1:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Air-handling and water systems of buildings - Microbial control Design, installation and commissioning
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
06-26-2021
English
05-02-2002
Specifies minimum requirements for the design, installation and commissioning of air-handling and water systems of buildings, other than sole occupancy dwellings, for the purposes of microbial control. It does not include requirements for refrigerated room airconditioners and non-ducted split systems.
Committee |
ME-062
|
DocumentType |
Standard
|
ISBN |
0 7337 4452 4
|
Pages |
14
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies minimum requirements for the design, installation and commissioning of air-handling and water systems of buildings for the purposes of microbial control. It does not include requirements for refrigerated room airconditioners and non-ducted split systems.NOTE: Refer to regulatory authority for the application of the criteria to buildings.Requirements specified in this Standard are not intended for the control of the wide range of discomfort symptoms that may afflict the occupants of some buildings.NOTES: 1 The Standard covers the most common known sources of the diseases associated with air-handling and water systems of buildings. Other sources, both known and potential, include cooling water systems for refrigeration equipment and air compressors, industrial heat exchangers when opened for cleaning, decorative fountains, spray irrigation systems, and industrial water-based cutting fluid systems.2 In the event of an outbreak of legionnaire’s disease, special action is necessary, which will be advised by the health authorities.3 Further information on the control of microbial growth in air-handling and water systems of buildings is given in HB 32.4 HB 61 provides details of the standard specifications in the NATSPEC series.5 Operation and maintenance requirements are given in AS/NZS 3666.2.
First published as part of AS 3666-1989.
Jointly revised and redesignated in part as AS/NZS 3666.1:1995.
Second edition 2002.
MP 52-2005 | Manual of authorization procedures for plumbing and drainage products |
AS 2345-2006 | Dezincification resistance of copper alloys |
AS 2913-2000 | Evaporative airconditioning equipment (Reconfirmed 2016) |
AS 1657-1992 | Fixed platforms, walkways, stairways and ladders - Design, construction and installation |
AS 4180.1-1994 | Drift loss from cooling towers - Laboratory measurement - Chloride balance method |
AS/NZS 2865:2001 | Safe working in a confined space |
AS/NZS 3666.2:1995 | Air-handling and water systems of buildings - Microbial control Operation and maintenance |
AS 1324.2-2003 | Air filters for use in general ventilation and airconditioning Methods of test |
HB 61-1999 | NATSPEC Handbook of building Standards extracts |
AS/NZS 3666.2:2002 | Air-handling and water systems of buildings - Microbial control Operation and maintenance |
AS/NZS 3500.2.2:1996 | National plumbing and drainage Sanitary plumbing and drainage - Acceptable solutions |
AS 1470-1986 | Health and safety at work - Principles and practices |
AS 2345-1992 | Dezincification resistance of copper alloys |
AS/NZS 1892.1:1996 | Portable ladders Metal |
AS/NZS 4020:1999 | Products for use in contact with drinking water |
SAA/SNZ HB32:1995 | Control of microbial growth in air-handling and water systems in buildings (Reconfirmed 2016) |
AS/NZS 3500.1.2:1998 | National plumbing and drainage Water supply - Acceptable solutions |
AS 1324.2-1996 | Air filters for use in general ventilation and airconditioning Methods of test |
AS 1668.2-1991 | The use of mechanical ventilation and air-conditioning in buildings Mechanical ventilation for acceptable indoor-air quality |
AS 1851.6-1997 | Maintenance of fire protection equipment - Management procedures for maintaining the fire and smoke control features of air-handling systems |
MP 52-2001 | Manual of authorization procedures for plumbing and drainage products |
AS/NZS 3500.4.2:1997 | National Plumbing and Drainage Hot water supply systems - Acceptable solutions |
AS 4254-2002 | Ductwork for air-handling systems in buildings |
HB 61-1999 | NATSPEC Handbook of building Standards extracts |
HB 260-2003 | Hospital acquired infections - Engineering down the risk |
AS 5059-2006 | Power station cooling tower water systems - Management of legionnaires' disease health risk (Reconfirmed 2016) |
AS 2913-2000 | Evaporative airconditioning equipment (Reconfirmed 2016) |
SAA/SNZ HB32:1995 | Control of microbial growth in air-handling and water systems in buildings (Reconfirmed 2016) |
AS/NZS 3666.2:2002 | Air-handling and water systems of buildings - Microbial control Operation and maintenance |
AS/NZS 3666.2:2002 | Air-handling and water systems of buildings - Microbial control Operation and maintenance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.