Specifies the minimum safety requirements related to the use of generating sets for the supply of electricity at voltages normally exceeding 50 V a.c. or 120 V d.c. Applies to electricity generating sets that are driven by internal combustion engines and that are used for the supply of electrical installations in buildings or items of equipment.

Committee
EL-001
DocumentType
Standard
ISBN
0 7337 6761 3
Pages
24
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out the minimum safety requirements related to the use of generating sets for the supply of electricity at voltages normally exceeding 50 V a.c. or 120 V d.c.The Standard applies to electricity generating sets that are driven by internal combustion engines, and which are used for the supply of electrical installations in buildings or items of electrical equipment.This Standard does not -(a) set out performance and constructional requirements for generating sets; or(b) specifically apply to specialized automatic sources of supply, e.g. no break systems or generating sets operated by Electricity Generating entities or Electricity Distributors; or (c) apply to uninterruptible power supplies; or(d) apply to other generation systems; such as: (i) Inverters.(ii) Photovoltaic arrays.(iii) Water or wind driven.While not intended to be applied to other than generating sets driven by internal combustion engines, the electrical principles could be applied to generating sets with other types of energy sources. Requirements for the performance and construction of transportable generating sets up to 25 kW are given in AS 2790.Requirements for the design, installation and operation of emergency power supplies in hospitals are given in AS/NZS 3009.Requirements for the design, installation and operation of uninterruptible power supplies are given in the AS 62040 series of Standards.Attention is drawn to the fact that some Regulatory Authorities have requirements for limitation of noise levels and pollution emissions.

Originated as AS 3010.1-1987.
Revised and redesignated AS/NZS 3010:2005.

AS/NZS 3947.6.1:2001 Low-voltage switchgear and controlgear Multiple Function equipment - Automatic transfer switching equipment
AS 2676.2-1992 Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells
AS 1940-2004 The storage and handling of flammable and combustible liquids
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 3011.2-1992 Electrical installations - Secondary batteries installed in buildings Sealed cells
AS/NZS 3009:1998 Electrical installations - Emergency power supplies in hospitals
AS 1319-1994 Safety signs for the occupational environment (Reconfirmed 2018)
AS 2790-1989 Electricity generating sets - Transportable (Up to 25 kW)
AS 2067-1984 Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV
AS 62040.2-2001 Uninterruptible power systems (UPS) - Electromagnetic compatibility (EMC) requirements
AS 3011.1-1992 Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells
AS 2676.1-1992 Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells
AS 62040.1.2-2003 Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations
AS 4024.1-1996 Safeguarding of machinery General principles
AS 62040.1.1-2003 Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas
AS 62040.3-2002 Uninterruptible power systems (UPS) Method of specifying the performance and test requirements
AS/NZS 1768(INT):2003 Lightning protection

AS/NZS 3012:2010 Electrical installations - Construction and demolition sites
AS/NZS 3002:2008 Electrical installations - Shows and carnivals
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 4509.1:2009 Stand-alone power systems Safety and installation (Reconfirmed 2017)
AS/NZS 3001:2008 Electrical installations - Transportable structures and vehicles including their site supplies
AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant
AS/NZS 4509.2:2010 Stand-alone power systems System design (Reconfirmed 2017)
AS/NZS 3760:2010 In-service safety inspection and testing of electrical equipment

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.