AS/NZS 3010:2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical installations - Generating sets
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
05-21-2024
English
06-27-2005
Specifies the minimum safety requirements related to the use of generating sets for the supply of electricity at voltages normally exceeding 50 V a.c. or 120 V d.c. Applies to electricity generating sets that are driven by internal combustion engines and that are used for the supply of electrical installations in buildings or items of equipment.
Committee |
EL-001
|
DocumentType |
Standard
|
ISBN |
0 7337 6761 3
|
Pages |
24
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out the minimum safety requirements related to the use of generating sets for the supply of electricity at voltages normally exceeding 50 V a.c. or 120 V d.c.The Standard applies to electricity generating sets that are driven by internal combustion engines, and which are used for the supply of electrical installations in buildings or items of electrical equipment.This Standard does not -(a) set out performance and constructional requirements for generating sets; or(b) specifically apply to specialized automatic sources of supply, e.g. no break systems or generating sets operated by Electricity Generating entities or Electricity Distributors; or (c) apply to uninterruptible power supplies; or(d) apply to other generation systems; such as: (i) Inverters.(ii) Photovoltaic arrays.(iii) Water or wind driven.While not intended to be applied to other than generating sets driven by internal combustion engines, the electrical principles could be applied to generating sets with other types of energy sources. Requirements for the performance and construction of transportable generating sets up to 25 kW are given in AS 2790.Requirements for the design, installation and operation of emergency power supplies in hospitals are given in AS/NZS 3009.Requirements for the design, installation and operation of uninterruptible power supplies are given in the AS 62040 series of Standards.Attention is drawn to the fact that some Regulatory Authorities have requirements for limitation of noise levels and pollution emissions.
Originated as AS 3010.1-1987.
Revised and redesignated AS/NZS 3010:2005.
AS/NZS 3947.6.1:2001 | Low-voltage switchgear and controlgear Multiple Function equipment - Automatic transfer switching equipment |
AS 2676.2-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells |
AS 1940-2004 | The storage and handling of flammable and combustible liquids |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 3011.2-1992 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS/NZS 3009:1998 | Electrical installations - Emergency power supplies in hospitals |
AS 1319-1994 | Safety signs for the occupational environment (Reconfirmed 2018) |
AS 2790-1989 | Electricity generating sets - Transportable (Up to 25 kW) |
AS 2067-1984 | Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV |
AS 62040.2-2001 | Uninterruptible power systems (UPS) - Electromagnetic compatibility (EMC) requirements |
AS 3011.1-1992 | Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells |
AS 2676.1-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells |
AS 62040.1.2-2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations |
AS 4024.1-1996 | Safeguarding of machinery General principles |
AS 62040.1.1-2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas |
AS 62040.3-2002 | Uninterruptible power systems (UPS) Method of specifying the performance and test requirements |
AS/NZS 1768(INT):2003 | Lightning protection |
AS/NZS 3012:2010 | Electrical installations - Construction and demolition sites |
AS/NZS 3002:2008 | Electrical installations - Shows and carnivals |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 4509.1:2009 | Stand-alone power systems Safety and installation (Reconfirmed 2017) |
AS/NZS 3001:2008 | Electrical installations - Transportable structures and vehicles including their site supplies |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
AS/NZS 4509.2:2010 | Stand-alone power systems System design (Reconfirmed 2017) |
AS/NZS 3760:2010 | In-service safety inspection and testing of electrical equipment |