• Shopping Cart
    There are no items in your cart

AS/NZS 1826:2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical equipment for explosive gas atmospheres - Special protection - Type of protection ‘s’

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

08-28-2024

Superseded by

AS/NZS 60079.33:2012

Language(s)

English

Published date

05-30-2008

Preview
US$58.24
Excluding Tax where applicable

Specifies requirements relating to the design, construction, testing and marking of electrical equipment which can be shown by test or assessment to be suitable for use in explosive gas atmospheres. It may be used by certification bodies in the testing and/or assessment of equipment for certification.

Committee
EL-014
DocumentType
Standard
ISBN
0 7337 8717 7
Pages
21
ProductNote
Withdrawn 17-09-2021.
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard gives the specific requirements for the construction, assessment and testing and marking of electrical equipment, parts of electrical equipment and Ex components with the type of protection known as special protection ‘s’.This Standard only applies for special protection as applied to electrical equipment, parts of electrical equipment and Ex components (hereinafter always referred to as ‘s’ equipment) applicable to Group I, Group II and Group III as defined in AS/NZS 60079.0.This Standard supplements the general requirements in AS/NZS 60079.0.It is applicable to equipment intended for equipment protection levels (EPLs) ‘Ma’, ‘Ga’, ‘Da’, ‘Mb’, ‘Gb’, ‘Db’, ‘Gc’ and ‘Dc’ as defined in AS/NZS 60079.0. The equipment has to be designed, tested and marked according to the equipment protection level for which it is assigned.This Standard is not applicable to equipment or any parts of equipment where one or more types of protection as described in AS/NZS 60079 series, or to combinations of types of protection as described in AS/NZS 60079.26, can be applied.Where the explosion-protection is achieved by using an established type of explosion-protection technique, then verification of the equipment has to be based on the requirements of that part of the AS/NZS 60079 series applicable to such technique. Any variations from these requirements have to be specified and agreed between the manufacturer and independent verifier.This Standard is also intended to apply to equipment operating in explosive gas atmospheres or explosive dust atmospheres, under conditions other than the atmospheric conditions given in AS/NZS 60079.0. However, additional assessment and testing related specifically to the intended conditions of use will be required. This is particularly important when the types of explosion-protection techniques known as ‘flameproof enclosure’ (AS/NZS 60079.1) and ‘intrinsic safety’ (AS/NZS 60079.11) are applied. Such conditions might include hypobaric, hyperbaric and oxygen enriched atmospheres. NOTES:1 This Standard is not intended to apply as a last resort in the event that equipment fails compliance to the AS/NZS 60079 series. Ex ’s’ is only considered where design options are limited for technical, operational or functional reasons2 This may mean that modification of the design will be necessary to meet the requirements of the established explosion-protection techniques. 3 This Standard may be used where equipment needs to be used at a higher EPL than the underlying protection techniques allow. If this occurs additional control measures and/or additional design and test requirements need to be applied. 4 Parts of equipment that can be designed and tested to standardized explosion-protection techniques should be so designed. Only those parts that achieve safety through alternative controls should be considered for Ex ’s’. An example where technical, operational or functional limitations preclude recognized explosion-protection techniques being used, is in gas detectors for EPL ‘Ma’ or ‘Ga’, using heated filaments. The major part of the equipment can comply with Ex ’ia’, but in order to function, the filaments, which are ignition sources, have to be exposed directly to the gas. The gas has to get to the filaments by diffusion or aspiration. In either case, the protection is to contain flame or explosion. This protection can only consist of one or more porous metal screens. These are permitted in Ex ’d’, but that explosion-protection technique is limited to EPL ‘Mb’ or ‘Gb’. A second layer of a different type of protection (as permitted in AS/NZS 60079.26 for EPL ‘Ga’), is not physically possible, as it cannot permit free access of gas. Ex ’s’ is therefore the only solution for this part of the gas detector.

Originated as AS 1826-1976.
Previous edition AS/NZS 1826(Int):2006.
Fourth edition 2008.

AS/NZS 60079.26:2007 Explosive atmospheres Equipment with equipment protection level (EPL) Ga
AS 4024.1603-2006 Safety of machinery Design of controls, interlocks and guards - Prevention of unexpected start-up (Reconfirmed 2014)
AS 4024.1201-2006 Safety of machinery - General principles - Basic terminology and methodology
AS 4024.1904-2006 Safety of machinery Displays, controls, actuators and signals - Indication, marking and actuation - Requirements for visual, auditory and tactile signals
AS 4024.1906-2006 Safety of machinery Displays, controls, actuators and signals - Indication, marking and actuation - Requirements for the location and operation of actuators
AS/NZS 60079.11:2006 Explosive atmospheres Equipment protection by intrinsic safety 'i'
AS/NZS 60079.0:2008 Explosive atmospheres Equipment - General requirements
AS 4024.1703-2006 Safety of machinery Principles for determining the dimensions required for access openings
AS 62061-2006 Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems
AS IEC 61511.3-2004 Functional safety - Safety instrumented systems for the process industry sector - Guidance for the determination of the required safety integrity levels (Reconfirmed 2015)
AS 4024.2-1998 Safeguarding of machinery Installation and commissioning requirements for electro-sensitive systems - Optoelectronic devices
AS 4024.1907-2006 Safety of machinery Displays, controls, actuators and signals - System of auditory and visual danger and information signals
AS/NZS 60079.1:2007 Explosive atmospheres Equipment protection by flameproof enclosures 'd'
AS 4024.1901-2006 Safety of machinery Displays, controls, actuators and signals - Ergonomic requirements for the design of displays and control actuators - General principles for human interactions with displays and control actuators
AS 4024.1903-2006 Safety of machinery Displays, controls, actuators and signals - Ergonomic requirements for the design of displays and control actuators - Control actuators
AS 2275.1-1979 Combustible gas detection instruments for use in explosive atmospheres - General requirements for explosion protection of electrical apparatus and systems
AS 4024.1701-2006 Safety of machinery Human body measurements - Basic human body measurements for technological design
AS 4024.1101-2006 Safety of machinery Terminology - Terms and definitions
AS 61508.4-1999 Functional safety of electrical/electronic/programmable electronic safety-related systems - Definition and abbreviations
AS 61508.7-2001 Functional safety of electrical/electronic/programmable electronic safety-related systems - Overview of techniques and measures
AS 61508.2-2001 Functional safety of electrical/electronic/programmable electronic safety-related systems - Requirements for electrical/electronic/programmable electronic safety-related systems
AS 4024.1601-2006 Safety of machinery Design of controls, interlocks and guarding - Guards - General requirements for the design and construction of fixed and movable guards
AS 4024.1302-2006 Safety of machinery Risk assessment - Reduction of risks to health and safety from hazardous substances emitted by machinery - Principles and specifications for machinery manufacturers
AS 4024.1602-2006 Safety of machinery Interlocking devices associated with guards - Principles for design and selection
AS 4024.1502-2006 Safety of machinery Design of safety related parts of control systems - Validation (Reconfirmed 2014)
AS/NZS 60079.15:2006 Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection, n electrical apparatus
AS 4024.1604-2006 Safety of machinery Design of controls, interlocks and guarding - Emergency stop - Principles for design
AS 4024.1905-2006 Safety of machinery Displays, controls, actuators and signals - Indication, marking and actuation - Requirements for marking
AS 4024.1801-2006 Safety of machinery Safety distances to prevent danger zones being reached by the upper limbs
AS 4024.1802-2006 Safety of machinery Safety distances and safety gaps - Safety distances to prevent danger zones being reached by the lower limbs
AS 61508.0-2006 Functional safety of electrical/electronic/programmable electronic safety-related systems Functional safety and AS 61508 (Reconfirmed 2015)
AS 61508.3-1999 Functional safety of electrical/electronic/programmable electronic safety-related systems - Software requirements
AS 4024.3-1998 Safeguarding of machinery Manufacturing and testing requirements for electro-sensitive systems - Optoelectronic devices
AS/NZS 60079.10:2004 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD)
AS 61508.5-1999 Functional safety of electrical/electronic/programmable electronic safety-related systems - Examples of methods for the determination of safety integrity levels
AS 4024.5-1998 Safeguarding of machinery Manufacturing and testing requirements for electro-sensitive systems - Pressure-sensitive devices
AS/NZS 61241.1:2005 Electrical apparatus for use in the presence of combustible dust Protection by enclosures 'tD'
AS/NZS 4024.1:2006 Series Safety of machinery Safety of machinery series
AS IEC 61511.2-2004 Functional safety - Safety instrumented systems for the process industry sector - Guidelines for the application of AS IEC 61511-1
AS IEC 61511.1-2004 Functional safety - Safety instrumented systems for the process industry sector - Framework, definitions, systems, hardware and software requirements
AS 4024.1803-2006 Safety of machinery Safety distances and safety gaps - Minimum gaps to prevent crushing of parts of the human body
AS 4024.1501-2006 Safety of machinery Design of safety related parts of control systems - General principles for design (Reconfirmed 2014)
AS 4024.1202-2006 Safety of machinery General principles - Technical principles
AS 4024.1902-2006 Safety of machinery Displays, controls, actuators and signals - Ergonomic requirements for the design of displays and control actuators - Displays
AS 4024.1704-2006 Safety of machinery Human body measurements - Anthropometric data
AS/NZS 60079.1.1:2002 Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd' - Method of test for ascertainment of maximum experimental safe gap
AS 4024.4-1998 Safeguarding of machinery Installation and commissioning requirements for electro-sensitive systems - Pressure-sensitive devices (Reconfirmed 2016)
AS 61508.1-1999 Functional safety of electrical/electronic/programmable electronic safety-related systems - General requirements
AS 4024.1702-2006 Safety of machinery Human body measurements - Principles for determining the dimensions required for openings for whole body access into machinery
AS 4024.1401-2006 Safety of machinery Ergonomic principles - Design principles - Terminology and general principles
AS 61508.6-2001 Functional safety of electrical/electronic/programmable electronic safety-related systems - Guidelines on the application of AS 61508.2 and AS 61508.3
AS 4024.1301-2006 Safety of machinery Risk assessment - Principles of risk assessment
AS/NZS 62013.1:2001 Caplights for use in mines susceptible to firedamp General requirements - Construction and testing in relation to the risk of explosion

AS/NZS 3800:2012 Electrical equipment for explosive atmospheres - Repair and overhaul
AS/NZS 2243.8:2014 Safety in laboratories Fume cupboards
AS/NZS 2243.9:2009 Safety in laboratories Recirculating fume cabinets
AS/NZS 60079.14:2009 Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD)