AS/NZS 1747:2003
AvailableSuperseded
An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by Intertek Inform as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.
Reeling, trailing and feeder cables used for mining - Repair, testing and fitting of accessories (Reconfirmed 2020)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
06-16-2003
Specifies standard procedures for the repair and testing of reeling, trailing and feeder cables used in mining applications.
Committee |
EL-003
|
DevelopmentNote |
Under Revision by DR AS/NZS 1747:2021.
|
DocumentType |
Standard
|
ISBN |
0 7337 5256 X
|
Pages |
52
|
ProductNote |
Reconfirmed 11/09/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 11/09/2020 |
PublisherName |
Standards Australia
|
Status |
AvailableSuperseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out requirements for the repair and testing of reeling, trailing and feeder cables used in underground coal mines, metalliferous mines, open cut mines, quarries and dredges. It also sets out requirements for the fitting of accessories to these cables. The Standard also details the inspection and replacement of plugs fitted to the cables and to the test equipment used for testing cables. NOTE: The Standard applies particularly to reeling and trailing cables complying with AS/NZS 1802 and AS/NZS 2802, and to cables with similar constructions complying with AS/NZS 1972, but is not restricted in application to such cables. Where type or code numbers are referred to in the Standard for trailing cables, the numbers are as specified in AS/NZS 1802 and AS/NZS 2802.
Originated as AS 1747-1975.
Previous edition 1993.
Jointly revised and designated as AS/NZS 1747:2003.
Reissued incorporating Amendment No.1 (August 2005).
AS 1834.1-1991 | Material for soldering Solder alloys (Reconfirmed 2018) |
AS/NZS 3800:1997 | Electrical equipment for explosive atmospheres - Overhaul and repair |
AS/NZS 1972:2002 | Electric cables - Underground coal mines - Other than reeling and trailing |
AS/NZS 2802:2000 | Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020) |
AS/NZS 3800:2005 | Electrical equipment for explosive atmospheres - Repair and overhaul |
AS 1299-1993 | Electrical equipment for coal mines - Flameproof restrained plugs and receptacles |
AS 1300-1989 | Electrical equipment for coal mines - Bolted flame-proof cable coupling devices |
AS/NZS 1660.3:1998 | Test methods for electric cables, cords and conductors Electrical tests (Reconfirmed 2017) |
AS/NZS 1972:2006 | Electric cables - Underground coal mines - Other than reeling and trailing (Reconfirmed 2020) |
AS 1683.15.2-1990 | Methods of test for elastomers Durometer hardness (Reconfirmed 2018) |
AS 2380.6-1988 | Electrical equipment for explosive atmospheres - Explosion-protection techniques Increased safety |
AS/NZS 1125:2001 | Conductors in insulated electric cables and flexible cords (Reconfirmed 2017) |
AS/NZS 1802:1995 | Electric cables - Reeling and trailing - For underground coal mining purposes |
AS/NZS 1802:2003 | Electric cables - Reeling and trailing - For underground coal mining purposes |
SA/SNZ HB 146:2018 | Management of electrical cable in mines and quarries |
AS/NZS 2290.1:2014 | Electrical equipment for coal mines - Introduction, inspection and maintenance For hazardous areas |
HB 239:2011 | Guidance on the repair and overhaul of electrical equipment for explosive atmospheres |
HB 242-2007 | High voltage mining equipment for use underground (Reconfirmed 2019) |
AS/NZS 1299:2009 | Electrical equipment for mines and quarries - Explosion-protected three-phase restrained plugs and receptacles for working voltages up to and including 3.3 kV (Reconfirmed 2020) |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.