View Superseded by

Above ground burial structures

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

02-07-2020

Superseded by

AS 4425:2020

Language(s)

English

Published date

01-01-1996

US$23.46
Excluding Tax where applicable

1 - AS 4425-1996 ABOVE-GROUND BURIAL STRUCTURES
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.3 REFERENCED DOCUMENTS
8 - 1.4 DEFINITIONS
8 - 1.4.1 Above-ground burial structure
8 - 1.4.2 Cemetery
8 - 1.4.3 Cemetery authority
8 - 1.4.4 Closure
8 - 1.4.5 Crypt space
8 - 1.4.6 Mausoleum
8 - 1.4.7 Natural stone cladding
8 - 1.4.8 Professional engineer
8 - 1.4.9 Seal
8 - 1.4.10 Structure
8 - 1.5 CRYPT IDENTIFICATION
10 - SECTION 2 MATERIALS AND COMPONENTS
10 - 2.1 GENERAL
10 - 2.2 CEMENT
10 - 2.3 NATURAL STONE
10 - 2.3.1 General
10 - 2.3.2 Assessment of durability
10 - 2.4 CONCRETE
10 - 2.5 MORTAR
10 - 2.6 MASONRY
10 - 2.7 REINFORCING STEEL
10 - 2.8 STRUCTURAL STEEL
10 - 2.9 GROUTING
10 - 2.10 FLEXIBLE COMPOUND BONDING AGENTS
11 - 2.11 LETTERING
11 - 2.12 GUNMETAL
12 - SECTION 3 DESIGN AND CONSTRUCTION
12 - 3.1 GENERAL
12 - 3.2 DESIGN LOADS
12 - 3.2.1 General
12 - 3.3 INTERMENT SPACE
12 - 3.3.1 Internal crypt dimension
12 - 3.3.2 Draining and venting of crypt spaces
12 - 3.3.3 Vermin proofing
13 - 3.3.4 Sealing of crypt space openings
13 - 3.3.5 Closure of openings
14 - 3.4 BUILDING
14 - 3.4.1 General
14 - 3.4.2 Door and floor
14 - 3.4.3 Stormwater drainage
14 - 3.4.4 Clearance of access
14 - 3.5 NATURAL STONE VENEER
14 - 3.5.1 Veneer fixing
14 - 3.5.2 Removable memorial panels
14 - 3.5.3 Joint width
14 - 3.5.4 Minimum thickness
14 - 3.6 OTHER FINISHES
14 - 3.7 POWER SUPPLY
14 - 3.7.1 General
14 - 3.7.2 Power to memorial panels

Specifies requirements for the structural and functional design and construction of structures which cater for the interment of human remains. Such a structure may contain any number of crypt spaces and includes structures commonly known as mausoleums, vaults, lined graves and similar.

Committee
BD-071
DocumentType
Standard
ISBN
0 7337 0698 3
Pages
8
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies some minimum requirements for the design (structural and functional) and construction of above-ground burial structures which cater for entombment of human remains. Such a structure may contain any number of crypt spaces, some of which may be below ground level. It does not set out to preclude artistic endeavour, providing this falls within the parameters of this Standard.

First published as AS 4425-1996.

AS 3679.1-1990 Structural steel - Hot-rolled bars and sections
AS 1170.4-2007 Structural design actions Earthquake actions in Australia (Reconfirmed 2018)
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 1304-1991 Welded wire reinforcing fabric for concrete
AS 1303-1991 Steel reinforcing wire for concrete
AS 4100-1998 Steel structures (Reconfirmed 2016)
AS/NZS 1170.2:2002 Structural design actions Wind actions
AS 1379-2007 Specification and supply of concrete (Reconfirmed 2017)
AS 3678-1990 Structural steel - Hot-rolled plates, floorplates and slabs
AS/NZS 1170.1:2002 Structural design actions Permanent, imposed and other actions
AS/NZS 3679.2:1996 Structural steel Welded I sections
AS 4100-1990 Steel structures
AS 1163-1991 Structural steel hollow sections
AS 4204-1994 Headstones and cemetery monuments
AS 1170.4-1993 Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads
AS 1170.3-1990 Minimum design loads on structures (known as the SAA Loading Code) - Snow loads
AS 1302-1991 Steel reinforcing bars for concrete
AS 3972-1997 Portland and blended cements
AS 1170.1-1981 Minimum design loads on structures (known as the SAA Loading Code) Dead and live loads
AS 2738.3-1984 Copper and copper alloys - Compositions and designations - Cast products
AS 1379-1997 Specification and supply of concrete
AS 3600-1994 Concrete structures
AS/NZS 3678:1996 Structural steel - Hot-rolled plates, floorplates and slabs
AS 3679.2-1991 Structural steel - Welded sections
AS/NZS 3679.1:1996 Structural steel Hot-rolled bars and sections
AS 1170.2-1989 Minimum design loads on structures (known as the SAA Loading Code) Wind loads
AS 3700-2001 Masonry structures
AS 3600-2001 Concrete structures
AS 3700-1988 Masonry in buildings (known as the SAA Masonry Code)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.