1 - AS 4273-1999 DESIGN, INSTALLATION AND USE OF PHARMACEUTICAL ISOLATORS
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - 1 SCOPE
7 - 2 OBJECTIVE
7 - 3 REFERENCED DOCUMENTS
8 - 4 DEFINITIONS
8 - 4.1 Alarm
8 - 4.2 Background environment
8 - 4.3 Clean environment
8 - 4.4 Controlled work space
8 - 4.5 Docking device
8 - 4.6 Exhaust filter
8 - 4.7 High efficiency particulate air (HEPA) filter
8 - 4.8 Isolator
8 - 4.9 Radiation protection system
8 - 4.10 Sanitization
8 - 4.11 Supply air
8 - 4.12 Transfer device
9 - 4.13 Type 1 Isolator
9 - 4.14 Type 2 Isolator
9 - 4.15 Unidirectional flow
9 - 4.16 Work site
9 - 5 DESIGN PRINCIPLES
9 - 5.1 General
9 - 5.2 Internal surfaces
9 - 5.3 Work space
9 - 5.4 Air change rate
10 - 5.5 Isolator pressure differentials
10 - 5.6 HEPA filter frames
10 - 5.7 HEPA filter testing facility
10 - 5.8 Transfer system
10 - 5.9 Air supply to a fixed transfer device
10 - 5.10 Radiopharmaceuticals
10 - 5.11 Change facility for exhaust filters
10 - 5.12 Discharge and exhaust air treatment
10 - 5.13 Exhaust blower system
10 - 5.14 Leak test
10 - 5.15 Sample ports
11 - 5.16 Pressure differential monitoring
11 - 5.17 Airflow monitoring
11 - 5.18 Alarms
11 - 5.19 Breach of containment
11 - 5.20 Transfer containment
11 - 6 PERFORMANCE
11 - 7 LABELLING
11 - 8 SITING OF ISOLATORS
11 - 8.1 Siting of isolator
11 - 8.2 Background environment
12 - 9 PHYSICAL, OPERATOR AND ENVIRONMENTAL CONTROL AND MONITORING
12 - 9.1 General
12 - 9.2 Commissioning program
13 - 9.3 Filter installation integrity
13 - 9.4 Air velocity
13 - 9.5 Pressure differentials
13 - 9.6 Isolator leak test
13 - 9.7 Glove and sleeve leak test
13 - 9.8 Routine monitoring
13 - 9.9 Cleaning and decontamination
13 - 9.10 Airborne particle counts
13 - 9.11 Time factors
19 - APPENDIX A - PURCHASER-SUPPLIER LIAISON
20 - APPENDIX B - STATUTORY AUTHORITIES FOR RADIATION SAFETY
22 - APPENDIX C - GUIDELINES FOR OPERATOR TRAINING
22 - C1 GENERAL
22 - C2 APPLICATION
22 - C3 HAND WASHING TECHNIQUES AND PROTECTIVE CLOTHING
22 - C4 GLOVES AND GAUNTLETS
22 - C5 TRANSFER SYSTEM
22 - C6 CLEANING
22 - C7 ASEPTIC TECHNIQUE
22 - C8 WORKING WITHIN THE ISOLATOR
22 - C9 VALIDATION
23 - APPENDIX D - GLOVES AND GAUNTLETS
23 - D1 GENERAL
23 - D2 GAUNTLETS
23 - D3 GLOVE/SLEEVE SYSTEM
24 - APPENDIX E - SUMMARY CERTIFICATE OF COMMISSIONING AND ROUTINE RECERTIFICATION TO AS 4273

Provides design requirements and guidance for the construction of pharmaceutical isolators, recommendations for the environment in which they are to be used, performance requirements and guidance on their installation and use.

Committee
ME-060
DocumentType
Standard
ISBN
0 7337 2510 4
Pages
18
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard gives design requirements and guidance for the construction of pharmaceutical isolators, recommendations for the environment in which they are to be used, performance requirements and guidance relating to their installation and use. It does not refer to flexible film or hybrid isolators or to devices intended to be used for handling of pathogenic organisms.NOTE: Appendix A provides guidance on information that should be discussed between purchaser and supplier.

Originated as AS/NZS 4273(Int):1995.
Revised and designated AS 4273-1999.
Reissued incorporating Amendment No. 1 (May 2000).

AS 1807.5-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of work zone integrity
AS 1807.24-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of recovery times of cleanrooms
AS 1807.20-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of sound level at installed workstations and safety cabinets
AS 1324.2-1996 Air filters for use in general ventilation and airconditioning Methods of test
AS 1807.10-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of air pressure of cleanrooms
AS 2567-1994 Laminar flow cytotoxic drug safety cabinets
AS 1807.1-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of air velocity and uniformity of air velocity in clean workstations and laminar flow safety cabinets
AS/NZS 4011:1997 Single-use examination gloves - Specification
AS 1386.1-1989 Cleanrooms and clean workstations - Principles of clean space control
AS 1807.8-1989 Cleanrooms, workstations and safety cabinets - Methods of test Particle counting in work zone by automatic particle counter
AS 1807.2-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of performance of clean workstations and laminar flow safety cabinets under loaded filter conditions
AS 2639-1994 Laminar flow cytotoxic drug safety cabinets - Installation and use
AS 4260-1997 High efficiency particulate air (HEPA) filters - Classification, construction and performance (Reconfirmed 2018)
AS 1807.6-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of integrity of terminally mounted HEPA filter installations
AS 1807.7-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of integrity of HEPA filter installations not terminally mounted
AS 1807.25-1990 Cleanrooms, workstations and safety cabinets - Methods of test Determination of gas tightness of outer shell of biological safety cabinets
AS 1807.15-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of illuminance

AS/NZS 2647:2000 Biological safety cabinets - Installation and use
AS 2252.5:2017 Controlled environments Cytotoxic drug safety cabinets (CDSC) - Design, construction, installation, testing and use

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.