• There are no items in your cart

AS 3735-2001

Current

Current

The latest, up-to-date edition.

Concrete structures for retaining liquids

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

03-13-2001

Preview
US$63.97
Excluding Tax where applicable

1 - AS 3735-2001 CONCRETE STRUCTURES FOR RETAINING LIQUIDS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE AND APPLICATION
6 - 1.1.1 Scope
6 - 1.1.2 Application
7 - 1.2 REFERENCED DOCUMENTS
7 - 1.3 DEFINITIONS
7 - 1.4 NOTATION
8 - 1.5 USE OF ALTERNATIVE MATERIALS OR METHODS
8 - 1.5.1 General
9 - 1.5.2 Existing structures
9 - 1.5.3 Ferrocement
9 - 1.6 DRAWINGS AND SPECIFICATIONS
9 - 1.6.1 Design data
9 - 1.6.2 Design details
10 - SECTION 2 LOADS AND LOAD COMBINATIONS
10 - 2.1 GENERAL
10 - 2.2 LOADS AND OTHER ACTIONS
10 - 2.2.1 Temperature
11 - 2.2.2 Moisture variation
11 - 2.2.3 Earthquake
11 - 2.2.4 Other actions
12 - 2.3 STABILITY DESIGN
12 - 2.4 LOAD COMBINATIONS FOR SERVICEABILITY
13 - SECTION 3 DESIGN FOR SERVICEABILITY AND STRENGTH
13 - 3.1 GENERAL
13 - 3.2 REINFORCED CONCRETE
13 - 3.2.1 General
13 - 3.2.2 Minimum reinforcement ratio
14 - 3.2.3 Limiting steel stresses for serviceability
15 - 3.2.4 Limiting concrete thickness
15 - 3.3 PRESTRESSED CONCRETE
15 - 3.3.1 General
15 - 3.3.2 Analysis
15 - 3.3.3 Limiting concrete stresses for serviceability
15 - 3.3.4 Non-tensioned reinforcement
16 - 3.3.5 Partial prestressing
17 - SECTION 4 DESIGN FOR DURABILITY
17 - 4.1 GENERAL
17 - 4.2 EXPOSURE CLASSIFICATION
18 - 4.3 REQUIREMENTS FOR CONCRETE
18 - 4.4 REQUIREMENTS FOR COVER TO REINFORCEMENT (BARS AND TENDONS)
18 - 4.4.1 General
19 - 4.4.2 Cover for concrete placement
19 - 4.4.3 Cover for corrosion protection
20 - 4.4.4 Cover modifications for special circumstances
20 - 4.5 DURABILITY OF METAL FIXTURES IN CONTACT WITH CONCRETE
20 - 4.6 DURABILITY OF WATERSTOPS, SEALANTS AND OTHER ASSOCIATED ITEMS
21 - SECTION 5 MATERIAL AND CONSTRUCTION REQUIREMENTS
21 - 5.1 GENERAL
21 - 5.2 CONCRETE
21 - 5.2.1 General
21 - 5.2.2 Curing
21 - 5.2.3 Pneumatically applied concrete
21 - 5.3 REINFORCEMENT
21 - 5.3.1 Protective coating
21 - 5.3.2 Tendons
22 - SECTION 6 JOINTS, WATERSTOPS, JOINT FILLERS, AND SEALANTS
22 - 6.1 JOINTS
22 - 6.1.1 Purpose
22 - 6.1.2 Non-movement
22 - 6.1.3 Movement
23 - 6.2 WATERSTOPS
23 - 6.3 JOINT FILLERS
23 - 6.4 SEALANTS
23 - 6.5 CONTAMINATION OF WATER
24 - SECTION 7 TESTING
24 - 7.1 GENERAL
24 - 7.2 TESTING FOR LIQUID-TIGHTNESS
24 - 7.3 TESTING OF LIQUID-RETAINING STRUCTURES
24 - 7.4 TESTING OF ROOFS

Specifies requirements for the design and installation of reinforced concrete structures used for retaining liquids at ambient temperatures. This Standard is limited to concrete with ultimate compressive strength in the range 20 MPa to 50 MPa at 28 days. For these structures, This Standard supplements and takes precedence over the requirements of AS 3600, Concrete structures.

Committee
CE-022
DocumentType
Standard
ISBN
0 7337 3714 5
Pages
19
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies requirements for concrete structures and members that include reinforcing steel or tendons, or both, used for retaining liquids at ambient temperature.The Standard supplements and takes precedence over the requirements of AS 3600.The principles of concrete design and construction embodied in this Standard apply to structures and members made of concrete(a) with a characteristic compressive strength at 28 days (f c) in the range of 20 MPa to50 MPa; and(b) of saturated, surface-dry density in the range of 1800 kg/m3 to 2800 kg/m3. The Standard does not apply to the design of(i) dams;(ii) aqueducts, hydraulic tunnels or similar structures;(iii) small septic tanks (see AS 1546.1);(iv) portable precast concrete water tanks of less than 25 000 L capacity;(v) fibre-impregnated concrete that does not comply with the design requirements and procedures of AS 3600; or(vi) precast concrete pipes (pressure and non-pressure) (see AS 4058).

Originated as AS 3735-1991.
Second edition 2001.

AS 3600-2001 Concrete structures
AS/NZS 4680:1999 Hot-dip galvanized (zinc) coatings on fabricated ferrous articles
AS/NZS 4680:2006 Hot-dip galvanized (zinc) coatings on fabricated ferrous articles (Reconfirmed 2017)
AS 1170.2-1989 Minimum design loads on structures (known as the SAA Loading Code) Wind loads
AS/NZS 3582.3:2002 Supplementary cementitious materials for use with portland and blended cement Amorphous silica
AS 3582.2-1991 Supplementary cementitious materials for use with portland cement Slag - Ground granulated iron blast-furnace
AS 3582.3-1994 Supplementary cementitious materials for use with portland cement - Silica fume
AS 2783-1992 Use of reinforced concrete for small swimming pools
AS/NZS 1170.2:2002 Structural design actions Wind actions
AS 1379-2007 Specification and supply of concrete (Reconfirmed 2017)
AS/NZS 1170.1:2002 Structural design actions Permanent, imposed and other actions
HB 79-1996 Alkali Aggregate reaction - Guidelines on Minimising the Risk of Damage to Concrete Structures in Australia
AS 3610-1995 Formwork for concrete
AS 3582.2-2001 Supplementary cementitious materials for use with portland and blended cement Slag - Ground granulated iron blast-furnace
AS 1170.4-1993 Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads
AS 1170.4-2007 Structural design actions Earthquake actions in Australia (Reconfirmed 2018)
AS 1170.1-1989 Minimum design loads on structures (known as the SAA Loading Code) Dead and live loads and load combinations
AS 1012.13-1992 Methods of testing concrete Determination of the drying shrinkage of concrete for samples prepared in the field or in the laboratory
AS/NZS 1546.1:1998 On-site domestic wastewater treatment units - Septic tanks
AS 3582.1-1998 Supplementary cementitious materials for use with portland and blended cement Fly ash
AS/NZS 4058:2007 Precast concrete pipes (pressure and non-pressure)
AS 2841-2005 Galvanized steel wire strand (Reconfirmed 2016)
AS 1379-1997 Specification and supply of concrete

AS 2118.1:2017 Automatic fire sprinkler systems General systems
AS 2159-1995 Piling - Design and installation
AS 3600-2001 Concrete structures
AS 3958.1-2007 Ceramic tiles Guide to the installation of ceramic tiles
AS 2419.1:2017 Fire hydrant installations System design, installation and commissioning
AS 2159-2009 Piling - Design and installation
HB 230-2008 Rainwater Tank Design and Installation Handbook
AS 2067-2008 Substations and high voltage installations exceeding 1 kV a.c.
AS 3600:2018 Concrete structures
AS 5100.5:2017 Bridge design Concrete
AS 4198-1994 Precast concrete access chambers for sewerage applications
AS 2783-1992 Use of reinforced concrete for small swimming pools

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.