• There are no items in your cart

AS 3565.1-2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Meters for water supply Cold water meters

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

09-16-2023

Superseded by

AS 3565.1-2010

Language(s)

English

Published date

01-14-2004

Preview
US$124.22
Excluding Tax where applicable

1 - AS 3565.1-2004 METERS FOR WATER SUPPLY - COLD WATER METERS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 REFERENCED DOCUMENTS
7 - 1.3 DEFINITIONS
7 - 1.3.1 Actual Volume (Va)
7 - 1.3.2 Adjustment device
7 - 1.3.3 Ancillary device
8 - 1.3.4 Associated measuring instruments
8 - 1.3.5 Calculator
8 - 1.3.6 Combination meter
8 - 1.3.7 Combined meter
8 - 1.3.8 Complete meter
8 - 1.3.9 Concentric meter
8 - 1.3.10 Concentric meter manifold
8 - 1.3.11 Correction device
8 - 1.3.12 Disturbance
8 - 1.3.13 Electronic device
9 - 1.3.14 Error of indication
9 - 1.3.15 First element of the register
9 - 1.3.16 Flow sensor or volume sensor
9 - 1.3.17 Flow rate (Q)
9 - 1.3.18 Indicated volume (Vi )
9 - 1.3.19 Influence quantity
9 - 1.3.20 Influence factor
9 - 1.3.21 In-line meter
9 - 1.3.22 Limiting conditions (LCs)
9 - 1.3.23 Minimum flow rate (Q1) (see Clause 1.6)
9 - 1.3.24 Maximum permissible error (MPE)
9 - 1.3.25 Measurement transducer
10 - 1.3.26 Nominal diameter (DN)
10 - 1.3.27 Overload flow rate (Q4) (see Clause 1.6)
10 - 1.3.28 Permanent flow rate (Q3) (see Clause 1.6)
10 - 1.3.29 Pressure loss (delta p)
10 - 1.3.30 Primary indication
10 - 1.3.31 Rated operating conditions (ROC)
10 - 1.3.32 Register
10 - 1.3.33 Relative error
10 - 1.3.34 Reference conditions
10 - 1.3.35 Sub-assembly
10 - 1.3.36 Transitional flow rate (Q2 ) (see Clause 1.6)
10 - 1.3.37 Verification scale interval
10 - 1.3.38 Working pressure
10 - 1.3.39 Working temperature
11 - 1.4 MARKING
11 - 1.4.1 Identification marks
11 - 1.4.2 Verification marks
11 - 1.5 PREFERRED UNITS
12 - 1.6 PREFERRED FLOW RATES
12 - 1.7 PREFERRED DIMENSIONS
13 - SECTION 2 MATERIALS AND COMPONENTS
13 - 2.1 MATERIALS
13 - 2.1.1 General
13 - 2.1.2 Copper alloys
13 - 2.1.3 Contamination of water
13 - 2.2 END CONNECTIONS
13 - 2.2.1 Threaded end connections
13 - 2.2.2 Flanged end connections
14 - 2.3 REGISTER
14 - 2.3.1 General
14 - 2.3.2 Unit of measurement, symbol and placement
14 - 2.3.3 Indicating range
14 - 2.3.4 Colour coding for registers
14 - 2.3.5 Types of register
16 - 2.3.6 Supplementary devices
17 - 2.3.7 Verification devices-First element of a register-Verification scale interval
17 - 2.4 CALIBRATION ADJUSTMENT DEVICE
17 - 2.5 PROTECTIVE DEVICES
18 - 2.6 FROST PROTECTION
18 - 2.7 STRAINERS
19 - SECTION 3 PERFORMANCE REQUIREMENTS
19 - 3.1 GENERAL
19 - 3.2 OPERATING TEMPERATURE
19 - 3.3 ULTRAVIOLET LIGHT EXPOSURE
19 - 3.4 TORQUE RESISTANCE OF THREADED END CONNECTIONS
19 - 3.5 WATERTIGHTNESS
19 - 3.6 NON-REVERSING DEVICE
19 - 3.7 REVERSE FLOW
19 - 3.8 PRESSURE LOSS
20 - 3.9 MAXIMUM ERROR OF MEASUREMENT
20 - 3.10 ENDURANCE
21 - SECTION 4 PERFORMANCE TESTS
21 - 4.1 GENERAL
21 - 4.2 PATTERN APPROVAL
21 - 4.3 TYPE TESTS
22 - APPENDIX A - MEANS FOR DEMONSTRATING COMPLIANCE WITH THIS STANDARD
22 - A1 SCOPE
22 - A2 RELEVANCE
22 - A3 PRODUCT CERTIFICATION
22 - A3.1 Definitions
23 - A3.2 Batch release test (BRT)
23 - A3.3 Type testing (TT)
23 - A4 TESTING
23 - A4.1 General
23 - A4.2 Type testing sampling
23 - A4.3 Retesting
23 - A4.4 Pattern approval
23 - A4.5 Acceptability of tests
26 - APPENDIX B - PURCHASING GUIDELINES
26 - B1 GENERAL
26 - B2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
26 - B3 CERTIFICATES
27 - APPENDIX C - METROLOGICAL REQUIREMENTS
27 - C1 SCOPE
27 - C2 METER DESIGNATION AND PERMANENT FLOW RATE (Q3)
27 - C3 MEASURING RANGE
27 - C4 RELATIONSHIP BETWEEN PERMANENT FLOW RATE (Q3 ) AND OVERLOAD FLOW RATE (Q4)
28 - C5 RELATIONSHIP BETWEEN TRANSITIONAL FLOW RATE (Q2) AND MINIMUM FLOW RATE (Q1)
28 - C6 REFERENCE FLOW RATE
28 - C7 MAXIMUM PERMISSIBLE ERROR
28 - C7.1 Sign of the error
28 - C7.2 Relative error (ε)
28 - C7.3 Temperature and pressure variations MPE requirements
28 - C7.4 Water meters with separate calculator and measurement transducer
28 - C7.5 Zero flow totalization
29 - APPENDIX D - TECHNICAL DATA
29 - D1 SCOPE
29 - D2 TECHNICAL DATA
31 - APPENDIX E - ULTRAVIOLET LIGHT EXPOSURE TEST
31 - E1 SCOPE
31 - E2 PRINCIPLE
31 - E3 APPARATUS
31 - E4 PROCEDURE
32 - E5 REPORT
33 - APPENDIX F - TORQUE RESISTANCE OF THREADED END CONNECTIONS TEST
33 - F1 SCOPE
33 - F2 PRINCIPLE
33 - F3 APPARATUS
33 - F4 PROCEDURE
34 - F5 REPORT
35 - APPENDIX G - WATERTIGHTNESS TEST
35 - G1 SCOPE
35 - G2 PRINCIPLE
35 - G3 APPARATUS
35 - G4 PROCEDURE
36 - G5 REPORT
37 - APPENDIX H - NON-REVERSING DEVICE LEAKAGE TEST
37 - H1 SCOPE
37 - H2 PRINCIPLE
37 - H3 APPARATUS
37 - H4 PROCEDURE
37 - H5 CALCULATION
38 - H6 REPORT
39 - APPENDIX I - REVERSE FLOW TEST
39 - I1 SCOPE
39 - I2 PRINCIPLE
39 - I3 APPARATUS
39 - I4 PROCEDURE
40 - I5 REPORT
41 - APPENDIX J - PRESSURE LOSS TEST
41 - J1 SCOPE
41 - J2 PRINCIPLE
41 - J3 APPARATUS
42 - J4 PROCEDURE
43 - J5 CALCULATIONS
43 - J6 REPORT
44 - APPENDIX K - ERROR OF MEASUREMENT TEST
44 - K1 SCOPE
44 - K2 PRINCIPLE
44 - K3 APPARATUS
44 - K3.2 Sampling
45 - K3.3 Errors (of indication)
45 - K4 PROCEDURE
46 - K5 REPORT
49 - APPENDIX L - ENDURANCE TEST
49 - L1 SCOPE
49 - L2 PRINCIPLE
49 - L3 ENDURANCE CRITERIA
49 - L4 APPARATUS
50 - L5 PROCEDURE
50 - L5.1 Meters with nominal flow rate (Q3) equal to or less than 16 kL/h
51 - L5.2 Meters with nominal flow rate (Q3) greater than 16 kL/h
51 - L6 CALCULATION
51 - L7 REPORT
53 - APPENDIX M - APPARATUS FOR TEST RIGS
53 - M1 SCOPE
53 - M2 CALIBRATED REFERENCE DEVICE
53 - M2.1 General
54 - M2.2 Uncertainties in the test methods
54 - M3 DRINKING WATER SUPPLY
54 - M4 TEMPERATURE INDICATOR
54 - M5 TIMING DEVICE
55 - M6 PRESSURE INDICATOR
55 - M7 DIFFERENTIAL PRESSURE INDICATOR
55 - M8 FLOW RATE INDICATOR
55 - M9 PRESSURE TAPPINGS

This Standard specifies requirements for water meters for use in cold water systems to measure the volume of cold drinking water or Type A or B recycled water using certain types of meters.

Committee
WS-024
DocumentType
Standard
ISBN
0 7337 5484 8
Pages
52
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for water meters for use in cold water systems to measure the volume of cold drinking water or Type A or B recycled water using the following types of meters: (a) Volumetric, not exceeding 63 kL/h.(b) Multi-jet, not exceeding 63 kL/h.(c) Single-jet meters, not exceeding 63 kL/h. (d) Helical vane meters with permanent flow rates not exceeding 250 kL/h. The operating conditions of the meters being—(i) working temperature ranges of 0.3°C to 30°C; and(ii) operating pressures not exceeding 1400 kPa. This Standard is applicable to meters that are self-contained and capable of continuously determining, within the accuracy limits of the class, the volume of cold drinking water that has flowed through them, and that are continuously indicating the volume on a cumulative basis. Means for demonstrating compliance with this Standard is given in Appendix A NOTE: Purchasing guidelines are given in Appendix B.

First published as AS 3565-1988.
Revised and redesignated AS 3565.1-1994.
Second edition 1993.
Third edition 2004.

AS/NZS 4020:2005 Testing of products for use in contact with drinking water
AS 1349-1986 Bourdon tube pressure and vacuum gauges (Reconfirmed 2018)
AS/NZS ISO 9002:1994 Quality systems - Model for quality assurance in production, installation and servicing
AS/NZS 3500.1:2003 Plumbing and drainage Water services
AS 4087-2004 Metallic flanges for waterworks purposes
AS 2345-1992 Dezincification resistance of copper alloys
AS 2345-2006 Dezincification resistance of copper alloys
AS 1722.2-1992 Pipe threads of Whitworth form Fastening pipe threads (Reconfirmed 2017)
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS/NZS 4020:2002 Testing of products for use in contact with drinking water
AS 4087-1996 Metallic flanges for waterworks purposes
AS 3558.5-1999 Methods of testing plastics and composite materials sanitary plumbing fixtures Determination of degradation by ultraviolet light (Reconfirmed 2016)

AS 3565.5-2004 Meters for water supply - Water meters with two integral single check valves
AS 5200.000-2006 Technical specification for plumbing and drainage products Procedures for certification of plumbing and drainage products (Reconfirmed 2018)
AS 3565.4-2007 Meters for cold and heated drinking and non-drinking water supplies In-service compliance testing (Reconfirmed 2019)
AS/NZS 2845.1:2010 Water supply - Backflow prevention devices Materials, design and performance requirements
MP 52-2005 Manual of authorization procedures for plumbing and drainage products
AS 3565.2-2004 Meters for water supply - Combination meters
AS 5200.000-2005 Technical specification for plumbing and drainage products Procedures for certification of plumbing and drainage products
ATS 4747.2-2008 Meters for non-urban water supply Specification for closed conduit meters fully charged
AS/NZS 2845.1:1998 Water supply - Backflow prevention devices Materials, design and performance requirements
ATS 4747.3-2008 Meters for non-urban water supply Specifications for open channel meters
AS 3565.3-2004 Meters for water supply - Water meters with integral dual check valves
ATS 5200.030-2007 Technical Specification for plumbing and drainage products Solenoid valves

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.