Built-in components for masonry construction Lintels and shelf angles (durability requirements)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
06-12-2020
This Standard specifies requirements for testing the durability performance of steel lintels and shelf angles to be built into masonry.
Committee |
BD-028
|
DocumentType |
Standard
|
ISBN |
978 1 76072 873 1
|
Pages |
28
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard specifies requirements for the durability performance of steel lintels and shelf angles to be built into masonry.
This Standard applies to lintels and shelf angles used in masonry construction described in AS 3700, AS 4773.1 and AS 4773.2.
NOTE 1 AS 2699.1 specifies the durability performance and test procedures for structural performance of wall ties used in masonry construction.
NOTE 2 AS 2699.2 specifies the durability performance and test procedures for structural performance of connectors and accessories used in masonry construction.
NOTE 3 Throughout this Standard, lintel signifies lintel or shelf angle, unless stated otherwise.
NOTE 4 The durability classifications employed in this Standard are compatible with the environments specified in ISO 9223, AS 4312—2008, AS 3700, AS 4773.1 and AS 4773.2.
NOTE 5 This Standard does not cover requirements for structural design or the method of its determination. Details for these are given by AS 3700, AS 4773.1, AS 4100, and AS/NZS 4600.
NOTE 6 Design and installation requirements for lintels and shelf angles are specified in AS 3700, AS 4773.1 (design) and AS 4773.2 (construction).
First published as AS/NZS 2699.3:2000.
Second edition 2002.
AS/NZS 2699.3:2002 revised and redesignated AS 2699.3:2020.
AS/NZS 4600:2018 | Cold-formed steel structures |
AS 1627.4-2005 | Metal finishing - Preparation and pretreatment of surfaces Abrasive blast cleaning of steel (Reconfirmed 2017) |
ISO 3951-1:2013 | Sampling procedures for inspection by variables — Part 1: Specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection for a single quality characteristic and a single AQL |
AS 2699.1:2020 | Built-in components for masonry construction Wall ties |
AS 4773.1:2015 | Masonry in small buildings Design |
AS 3894.3-2002 | Site testing of protective coatings Determination of dry film thickness (Reconfirmed 2013) |
AS/NZS 3750.6:2009 | Paints for steel structures Full gloss polyurethane (two-pack) (Reconfirmed 2020) |
AS/NZS 4791:2006 | Hot-dip galvanized (zinc) coatings on ferrous open sections, applied by an in-line process (Reconfirmed 2017) |
AS ISO/IEC 17025:2018 | General requirements for the competence of testing and calibration laboratories |
AS 4773.2:2015 | Masonry in small buildings Construction |
ISO 3951-4:2011 | Sampling procedures for inspection by variables — Part 4: Procedures for assessment of declared quality levels |
AS 1397-2011 | Continuous hot-dip metallic coated steel sheet and strip - Coatings of zinc and zinc alloyed with aluminium and magnesium |
ISO 9227:2017 | Corrosion tests in artificial atmospheres — Salt spray tests |
ISO 9223:2012 | Corrosion of metals and alloys — Corrosivity of atmospheres — Classification, determination and estimation |
AS/NZS 4680:2006 | Hot-dip galvanized (zinc) coatings on fabricated ferrous articles (Reconfirmed 2017) |
AS 4312-2008 | Atmospheric corrosivity zones in Australia |
AS/NZS 3750.9:2009 | Paints for steel structures Organic zinc-rich primer (Reconfirmed 2019) |
ISO 19840:2012 | Paints and varnishes — Corrosion protection of steel structures by protective paint systems — Measurement of, and acceptance criteria for, the thickness of dry films on rough surfaces |
AS 3700:2018 | Masonry Structures |
AS/NZS 2312.2:2014 | Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings Hot dip galvanizing |
ASTM A 240/A240M : 2019 | Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications |
AS 2699.2:2020 | Built-in components for masonry construction Connectors and accessories |
ISO 3951-2:2013 | Sampling procedures for inspection by variables — Part 2: General specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection of independent quality characteristics |
AS 2312.1:2014 | Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings Paint coatings |
AS 4100-1998 | Steel structures (Reconfirmed 2016) |
AS 2331.3.1-2001 | Methods of test for metallic and related coatings Corrosion and related property tests - Neutral salt spray test (NSS test) (Reconfirmed 2017) |
ISO 3951-3:2007 | Sampling procedures for inspection by variables Part 3: Double sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection |
ASTM B 117 : 2019 | Standard Practice for Operating Salt Spray (Fog) Apparatus |
AS 2331.1.4-2001 | Methods of test for metallic and related coatings Local thickness tests - Magnetic induction and eddy current methods |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
ISO 3951-5:2006 | Sampling procedures for inspection by variables Part 5: Sequential sampling plans indexed by acceptance quality limit (AQL) for inspection by variables (known standard deviation) |
AS 4848.1:2019 | Application specifications for coating systems Single coat inorganic (ethyl) zinc silicate - Solvent-borne |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.