AS 2567-2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Laminar flow cytotoxic drug safety cabinets

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

08-01-2017

Superseded by

AS 2252.5:2017

Language(s)

English

Published date

01-01-2002

Preview
US$63.97
Excluding Tax where applicable

1 - AS 2567-2002 LAMINAR FLOW CYTOTOXIC DRUG SAFETY CABINETS
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - 1 SCOPE
7 - 2 REFERENCED DOCUMENTS
8 - 3 GENERAL REQUIREMENTS
9 - 4 CONSTRUCTION REQUIREMENTS
9 - 4.1 Outer shell
9 - 4.2 Work zone
9 - 4.2.1 General
9 - 4.2.2 Viewing window
10 - 4.2.3 Work access opening
10 - 4.2.4 Testing cover
10 - 4.2.5 Work zone illumination
10 - 4.2.6 Work floor
10 - 4.2.7 Additional requirements
13 - 4.2.8 Sump
13 - 4.2.9 Grilles
14 - 4.2.10 Knee space
14 - 4.3 Filters and filter installations
14 - 4.3.1 General
14 - 4.3.2 Prefilters
14 - 4.3.3 HEPA filters
15 - 4.3.4 Activated carbon filters
15 - 4.4 Blowers and alarm systems
15 - 4.4.1 Blowers
15 - 4.4.2 Blower alarm systems
16 - 4.5 Access panels
16 - 4.6 Electrical services
16 - 4.7 Germicidal ultraviolet lamps
16 - 4.8 Post-use overrun control
16 - 5 PERFORMANCE REQUIREMENTS
16 - 5.1 General
17 - 5.2 Critical for cabinet functions
17 - 5.2.1 Filter installation integrity
17 - 5.2.2 Air barrier containment
17 - 5.2.3 Work zone integrity
17 - 5.2.4 Air velocity and uniformity in the work zone
17 - 5.2.5 Alarm operational adjustment
17 - 5.3 Other requirements
17 - 5.3.1 Sound level
18 - 5.3.2 Lighting
18 - 5.3.3 Vibration
18 - 6 MARKING
19 - APPENDIX A - ERGONOMICS
19 - A1 GENERAL
19 - A2 CONSIDERATION OF ERGONOMICS FOR SAFETY CABINETS AND ISOLATORS
19 - A2.1 General
20 - A2.2 Design
20 - A2.3 Purchase and use

Specifies requirements for open-fronted laminar flow cytotoxic drug safety cabinets which are intended to provide protection for personnel, the environment, and cytotoxic drug products

Committee
ME-060
DocumentType
Standard
ISBN
0 7337 4826 0
Pages
14
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for open-fronted laminar flow cytotoxic drug safety cabinets which are intended to provide protection for personnel, the environment, and cytotoxic drug products. These cabinets may also find wider application for handling other hazardous drugs and materials (see AS 2639). They are primarily designed to contain aerosols, and are not intended to provide complete protection against particles which may be ejected during procedures such as tablet crushing and grinding. This Standard should be read in conjunction with AS 2639 which describes recommended practices for installation and use of these cabinets. NOTE: Ergonomic considerations for the design and use of cytotoxic drug safety cabinets are addressed in Appendix A.

First published as AS 2567-1982.
Second edition 1994.
Third edition 2002.

AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 4260-1997 High efficiency particulate air (HEPA) filters - Classification, construction and performance (Reconfirmed 2018)
AS 1324.2-2003 Air filters for use in general ventilation and airconditioning Methods of test
AS 1324.2-1996 Air filters for use in general ventilation and airconditioning Methods of test
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 1807.22-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets
AS 1807.6-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of integrity of terminally mounted HEPA filter installations
AS 2639-1994 Laminar flow cytotoxic drug safety cabinets - Installation and use
AS 1807.15-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of illuminance
AS/NZS 2107:2000 Acoustics - Recommended design sound levels and reverberation times for building interiors
AS 1807.5-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of work zone integrity
AS 1807.18-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of vibration in workstations, safety cabinets and pharmaceutical isolators
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS 2659.1-1988 Guide to the use of sound measuring equipment - Portable sound level meters
AS 1319-1994 Safety signs for the occupational environment (Reconfirmed 2018)
AS 1807.1-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air velocity and uniformity of air velocity in clean workstations, laminar flow safety cabinets and pharmaceutical isolators
AS 1807.2-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of performance of clean workstations, laminar flow safety cabinets and pharmaceutical isolators under loaded filter conditions

AS/NZS 2243.3:2002 Safety in laboratories Microbiological aspects and containment facilities
AS/NZS 4020:2002 Testing of products for use in contact with drinking water
AS/NZS 2982:2010 Laboratory design and construction
AS 1386.1-1989 Cleanrooms and clean workstations - Principles of clean space control
AS 2252.1-2002 Biological safety cabinets - Biological safety cabinets (Class I) for personnel and environment protection
AS/NZS 2243.8:2014 Safety in laboratories Fume cupboards
AS 2639-1994 Laminar flow cytotoxic drug safety cabinets - Installation and use
AS 2252.2-2004 Biological safety cabinets - Laminar flow biological safety cabinets (Class II) for personnel, environment and product protection
AS/NZS 2243.8:2006 Safety in laboratories - Fume cupboards
AS/NZS 2647:2000 Biological safety cabinets - Installation and use
AS/NZS 2243.1:2005 Safety in laboratories Planning and operational aspects
AS/NZS 4020:2018 Testing of products for use in contact with drinking water
AS 1386.5-1989 Cleanrooms and clean workstations - Clean workstations
AS/NZS 2243.3:2010 Safety in laboratories Microbiological safety and containment
AS 2252.5:2017 Controlled environments Cytotoxic drug safety cabinets (CDSC) - Design, construction, installation, testing and use
AS 3578-1993 Cast iron non-return valves for general purposes
AS/NZS 4020:2005 Testing of products for use in contact with drinking water
AS 1807.22-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.