AS 2118.6-2012
Current
The latest, up-to-date edition.
Automatic fire sprinkler systems Combined sprinkler and hydrant systems in multistorey buildings
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
09-21-2012
Sets out minimum criteria for the design, installation and commissioning of combined sprinkler and hydrant systems (including fire hose reels where appropriate) in multistorey buildings greater than two storeys in height.
Committee |
FP-004
|
DocumentType |
Standard
|
ISBN |
978 1 74342 227 4
|
Pages |
66
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out minimum criteria for the design, installation and commissioning of combined sprinkler and hydrant systems (including fire hose reels where appropriate) in multistorey buildings greater than two storeys in height.NOTES: 1The installation of a combined system to this Standard is a choice; it is not mandatory to install a combined sprinkler and hydrant sprinkler system in multistorey buildings.2This Standard does not apply to buildings less than three storeys in height, for example, large floor area factories and warehouses where the sprinkler and hydrant systems are normally provided to AS 2118.1 and AS 2419.1 respectively. Such buildings may have an in-ground common fire ring main (see AS 2118.1).3This Standard should not be used for sprinkler systems classified as high hazard(see AS 2118.1 and Appendix M).1.2 OBJECTIVE
Originated as AS2118.6-1995.
Second edition 2012.
AS/NZS 3500.1:2003 | Plumbing and drainage Water services |
AS/NZS 3013:2005 | Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020) |
AS 4118.1.4-1994 | Fire sprinkler systems Components - Valve monitors (Reconfirmed 2013) |
AS 2118.1-1995 | Automatic fire sprinkler systems - Standard |
AS 2941-2008 | Fixed fire protection installations - Pumpset systems |
AS 4118.1.3-1995 | Fire sprinkler systems Components - Water motor alarms (Reconfirmed 2013) |
AS 4118.1.7-1996 | Fire sprinkler systems Components - Alarm valves (dry) (Reconfirmed 2013) |
AS 1670.1-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire |
AS 4118.1.6-1995 | Fire sprinkler systems Components - Stop valves and non-return valves (Reconfirmed 2013) |
AS 2419.1-2005 | Fire hydrant installations System design, installation and commissioning |
AS 4118.1.1-1996 | Fire sprinkler systems Components - Sprinklers and sprayers (Reconfirmed 2013) |
AS 4118.1.2-1996 | Fire sprinkler systems Components - Alarm valves (wet) (Reconfirmed 2013) |
AS 4118.1.8-1999 | Fire sprinkler systems Components - Pressure-reducing valves (Reconfirmed 2013) |
AS 2419.3-2012 | Fire hydrant installations Fire brigade booster connections |
AS 2118.1-2006 | Automatic fire sprinkler systems General systems |
SAA HB20-1996 | Graphical symbols for fire protection drawings (Reconfirmed 2018) |
AS 2118.1-1999 | Automatic fire sprinkler systems General requirements |
AS 2419.2-2009 | Fire hydrant installations Fire hydrant valves |
AS 1670.3-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning - Fire alarm monitoring |
AS 4118.1.5-1996 | Fire sprinkler systems Components - Deluge and pre-action valves (Reconfirmed 2013) |
AS 4118.2.1-1995 | Fire sprinkler systems Piping - General (Reconfirmed 2013) |
AS 2118.10-1995 | Automatic fire sprinkler systems Approval documentation (Reconfirmed 2013) |
AS 2304:2019 | Water storage tanks for fire protection systems |
AS 2118.1:2017 | Automatic fire sprinkler systems General systems |
AS 1940:2017 | The storage and handling of flammable and combustible liquids |
AS/NZS 3500.1:2018 | Plumbing and drainage Water Services |
AS/NZS 2243.8:2014 | Safety in laboratories Fume cupboards |
AS 2419.1:2017 | Fire hydrant installations System design, installation and commissioning |
AS 2941-2013 | Fixed fire protection installations - Pumpset systems |
AS/NZS 3084:2017 | Telecommunications installations - Telecommunications pathways and spaces for commercial buildings |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
AS/NZS 2293.1:2018 | Emergency lighting and exit signs for buildings System design, installation and operation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.