• There are no items in your cart

AS 1735.7-1998

Current

Current

The latest, up-to-date edition.

Lifts, escalators and moving walks Stairway lifts

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

05-05-1998

US$36.65
Excluding Tax where applicable

1 - AS 1735.7-1998 LIFTS, ESCALATORS AND MOVING WALKS - STAIRWAY LIFTS
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 APPLICATION
6 - 3 REFERENCED DOCUMENTS
7 - 4 DEFINITIONS
7 - 4.1 Stairway chair lift
7 - 4.2 Stairway lift
7 - 4.3 Stairway platform lift
7 - 5 RATED CAPACITY
7 - 6 RATED LOAD
7 - 7 PLATFORM AREA
7 - 8 SPEED
7 - 9 SLOPE
7 - 10 WEATHER RESISTANCE
7 - 11 FLUSHNESS OF STAIRWAY
8 - 12 ACCESS ALONG STAIRWAY
8 - 13 SIDE CLEARANCE
8 - 14 END PERSON CLEARANCE
8 - 15 HEAD CLEARANCE
8 - 16 FACTORS OF SAFETY
8 - 16.1 General
8 - 16.2 Suspension means
9 - 17 GUIDES AND SUPPORTS
9 - 18 CARRIAGE
9 - 18.1 Provision
9 - 18.2 Chair types
9 - 18.3 Platform types
9 - 19 DRIVING MACHINERY
9 - 19.1 Power unit
9 - 19.2 Drums and sheaves
9 - 19.3 Ropes and chains
9 - 19.3.1 Types
9 - 19.3.2 Equalizing
9 - 19.3.3 Chain and chain wheel drive
10 - 19.4 Drive from motor
10 - 19.5 Final drive
10 - 20 ENCLOSURES AND GUARDING
10 - 21 MACHINE BRAKES
10 - 22 SAFETY DEVICES
10 - 22.1 Safety gear
10 - 22.2 Safety gear springs
10 - 22.3 Slack rope or chain switch
10 - 22.4 Terminal stopping devices
11 - 22.5 Obstruction shut-off
11 - 22.5.1 Stairway chairlift
11 - 22.5.2 Stairway platform lift
11 - 22.6 Buffers
11 - 23 OPERATING CONTROLS
11 - 23.1 General
11 - 23.2 Carriage out of sight of landing controls
11 - 24 ELECTRICAL
11 - 24.1 General
11 - 24.2 Travelling cables
11 - 24.3 Power supply voltage
11 - 24.4 Control of power supply
11 - 24.5 Earthing
12 - 24.6 Overspeed switch
12 - 24.7 Control circuit and operating circuit
12 - 25 LIGHTING
12 - 26 EMERGENCY COMMUNICATION FOR WHEELCHAIR PLATFORM LIFTS
12 - 27 NOTICES
14 - APPENDIX A - INSPECTION
14 - APPENDIX B - GUIDE FOR SELECTION OF LIFT TYPE

Specifies requirements for power-operated stairway lifts intended for use by persons with limited mobility. The lifts consist of a carriage, incorporating a platform, or a chair, or both, for raising or lowering persons along stairways.

Committee
ME/4
DocumentType
Standard
ISBN
0 7337 1874 4
Pages
9
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies requirements for power-operated stairway lifts intended for use by persons with limited mobility. The lifts consist of a carriage, incorporating a platform or a chair, or both, for raising or lowering persons along stairways. This Standard is complementary to AS 1735.1, but the requirements of this Standard take precedence over corresponding requirements of that Standard. Inspection requirements are given in Appendix A.NOTE: Guidance on selection of lift type is given in Appendix B.

Originated as part of AS CA3-1935.
Previous edition AS 1735.7-1987.
Fifth edition 1998.

AS 1735.3-1995 Lifts, escalators and moving walks Passenger and goods lifts - Electrohydraulic
AS 1735.1-2003 Lifts, escalators and moving walks General requirements
AS 1735.3-2002 Lifts, escalators and moving walks Passenger and goods lifts - Electrohydraulic
AS 1735.13-1986 Lifts, escalators and moving walks Lifts for persons with limited mobility - Manually powered
AS 1735.15-1990 Lifts, escalators and moving walks Lifts for people with limited mobility - Restricted use - Non-automatically controlled
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 1735.2-1997 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS 1532-1974 Short pitch transmission precision roller chains and chain wheels
AS 1735.2-2001 Lifts, escalators and moving walks Passenger and goods lifts - Electric
AS 1735.17-1995 Lifts, escalators and moving walks Lifts for people with limited mobility - Restricted use - Water-drive
AS 3569-1989 Steel wire ropes
AS 1735.15-2002 Lifts, escalators, and moving walks Low-rise passenger lifts - Non-automatically controlled
AS 1735.16-1993 Lifts, escalators and moving walks Lifts for persons with limited mobility - Restricted use - Automatically controlled
AS 1735.14-1998 Lifts, escalators and moving walks Low-rise platforms for passengers
AS 1735.1-1999 Lifts, escalators and moving walks - General requirements

AS 2118.1:2017 Automatic fire sprinkler systems General systems
AS/NZS 2982:2010 Laboratory design and construction
AS/NZS 1170.1:2002 Structural design actions Permanent, imposed and other actions
AS 1735.14-1998 Lifts, escalators and moving walks Low-rise platforms for passengers
AS/NZS 4024.1:2006 Series Safety of machinery Safety of machinery series
AS 4024.1202-2006 Safety of machinery General principles - Technical principles
AS/NZS 1680.2.1:2008 Interior and workplace lighting Specific applications - Circulation spaces and other general areas
AS 1418.8-2008 Cranes, hoists and winches Special purpose appliances (Reconfirmed 2018)
AS 1428.2-1992 Design for access and mobility Enhanced and additional requirements - Buildings and facilities (Reconfirmed 2015)
AS 2118.1-1995 Automatic fire sprinkler systems - Standard
AS 1735.8-1986 Lifts, escalators and moving walks (known as the SAA Lift Code) Inclined lifts
AS 2118.1-2006 Automatic fire sprinkler systems General systems
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 2293.1:2018 Emergency lighting and exit signs for buildings System design, installation and operation

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.