• There are no items in your cart

AS 1375-1985

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Industrial fuel-fired appliances (known as the SAA Industrial Fuel-fired Appliances Code)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-24-2021

Superseded by

AS 1375-2013

Language(s)

English

Published date

01-01-1985

Preview
US$72.80
Excluding Tax where applicable

1 - AS 1375-1985 SAA INDUSTRIAL FUEL-FIRED APPLIANCES CODE
4 - PREFACE
5 - CONTENTS
7 - FOREWORD
9 - SECTION 1. SCOPE AND GENERAL
9 - 1.1 SCOPE
9 - 1.2 APPLICATION
9 - 1.3 NEW DESIGNS AND INNOVATIONS
9 - 1.4 INTERPRETATIONS
9 - 1.5 REFERENCED DOCUMENTS
9 - 1.6 DEFINITIONS
9 - 1.6.1 Appliance
9 - 1.6.2 Appliance management system
9 - 1.6.3 Approval, approved
9 - 1.6.4 Authority
9 - 1.6.5 Burner management system
9 - 1.6.6 Chimney
9 - 1.6.7 Critical time
9 - 1.6.8 Dilution
9 - 1.6.9 Duct
9 - 1.6.10 Flame simulation
9 - 1.6.11 Flue
9 - 1.6.12 Fresh air
9 - 1.6.13 Installer
9 - 1.6.14 Interlock
9 - 1.6.15 Lockout
9 - 1.6.16 May
9 - 1.6.17 Power flue
9 - 1.6.18 Proved
10 - 1.6.19 Purging
10 - 1.6.20 Shall and should
10 - 1.6.21 Shutdown
10 - 1.6.22 Start-fuel rate
11 - SECTION 2. APPLIANCE DESIGN AND CONSTRUCTION
11 - 2.1 GENERAL DESIGN
11 - 2.1.1 Appliance structure
11 - 2.1.2 Ladders or steps
11 - 2.1.3 Protection of equipment
11 - 2.1.4 Accumulation within cavity walls
11 - 2.1.5 Insulation
11 - 2.1.6 Ignition hazards
11 - 2.1.7 Strength of doors
11 - 2.1.8 Prevention of accidental fires
11 - 2.1.9 Free circulation
11 - 2.1.10 Adjusting devices
11 - 2.1.11 Air inlet guards
11 - 2.1.12 Systems for heating by hot fluids
11 - 2.1.13 Electrical equipment
11 - 2.1.14 Gas piping and components
11 - 2.2 MATERIALS
11 - 2.2.1 Suitability
11 - 2.2.2 Combustibility
12 - 2.3 SAFETY OF PERSONNEL
12 - 2.3.1 Working inside appliances
12 - 2.3.2 Door handles
12 - 2.3.3 Injury or burns
12 - 2.3.4 Projections
12 - 2.3.5 Explosion reliefs
12 - 2.4 OPERATING AND MAINTENANCE PROVISIONS
12 - 2.4.1 Control equipment
12 - 2.4.2 Automatic appliance management systems
12 - 2.4.3 Manual functions
12 - 2.4.4 Visual flame checking provisions
12 - 2.4.5 Removable components
12 - 2.4.6 Special tools
12 - 2.4.7 Cleaning
12 - 2.4.8 Maintenance provisions
12 - 2.5 EXPLOSION DAMAGE PROTECTION
12 - 2.5.1 Provision of protection
13 - 2.5.2 Explosion relief operation
13 - 2.5.3 Explosion relief location
13 - 2.6 TEMPERATURE HAZARDS
13 - 2.6.1 Components, floors, walls
13 - 2.6.2 Power failure
13 - 2.7 INSTRUCTIONS
13 - 2.7.1 Instructions
14 - 2.7.2 Additional information
14 - 2.8 MARKING
14 - 2.8.1 Appliance data
14 - 2.8.2 Indicators, gauges, and controls
14 - 2.8.3 Emergency stops
14 - 2.8.4 Colour code
15 - SECTION 3. COMBUSTION SYSTEM
15 - 3.1 GENERAL
15 - 3.1.1 General suitability
15 - 3.1.2 Movable burners
15 - 3.1.3 Fuel remaining in burner
15 - 3.2 IGNITION SYSTEM CONSTRUCTION.
15 - 3.2.1 Location and fixing
15 - 3.2.2 Spark-ignition system
15 - 3.2.3 Manual ignition
15 - 3.2.4 Manual ignition equipment
15 - 3.3 SUPERVISION, CONTROL, AND SAFE PROCEDURES
15 - 3.3.1 General principles
16 - 3.3.2 Automatic systems
16 - 3.3.3 Manual systems
16 - 3.3.4 Interlocking controls
16 - 3.4 STARTING AND IGNITION
16 - 3.4.1 Ignition procedures
16 - 3.4.2 Performance
16 - 3.4.3 Attempted re-ignition
16 - 3.4.4 Ignition during purging
16 - 3.4.5 Multiple main burner appliances
16 - 3.4.6 Sequential ignition of multiple main burners
16 - 3.4.7 Simultaneous ignition of multiple main burners
17 - 3.5 FLAME FAILURE DURING OPERATION
17 - 3.5.1 Flame supervision and failure protection
17 - 3.5.2 Flame failure response time
17 - 3.5.3 Relighting after flame failure
17 - 3.5.4 Extraneous ignition sources
17 - 3.6 MULTIFUEL FIRING
17 - 3.6.1 Application
17 - 3.6.2 Alternative firing
17 - 3.6.3 Simultaneous firing
18 - 3.7 SHUTDOWN PROCEDURES
18 - 3.7.1 Safety
18 - 3.7.2 Normal shutdown
18 - 3.7.3 Abnormal shutdown
18 - 3.8 PURGING
18 - 3.8.1 When to purge
18 - 3.8.2 Method of purging
18 - 3.8.3 Completeness of purging
18 - 3.8.4 Manually controlled purging
18 - 3.8.5 Proof of purge air
18 - 3.8.6 Dampers
19 - SECTION 4. CONTROL OF NON-FUEL COMBUSTIBLE ATMOSPHERES
19 - 4.1 SCOPE OF SECTION
19 - 4.2 PREVENTION OR RELIEF OF EXPLOSIONS
19 - 4.2.1 Explosion prevention
19 - 4.2.2 High concentration of volatiles
19 - 4.2.3 Explosion relief
19 - 4.3 AIR DILUTION AND PURGING
19 - 4.3.1 Method of providing dilution air
19 - 4.3.2 Dilution air quantities
19 - 4.3.3 Air distribution
19 - 4.3.4 Purging
19 - 4.4 VAPOUR AND DUST REMOVAL
19 - 4.4.1 Safe disposal
19 - 4.4.2 Incineration
19 - 4.4.3 Leakage of hazardous materials
20 - SECTION 5. INSTALLATION, COMMISSIONING, AND OPERATION
20 - 5.1 INSTALLER’S RESPONSIBILITY
20 - 5.1.1 Instructions
20 - 5.1.2 Defective equipment
20 - 5.1.3 Suitability for fuel, electricity
20 - 5.2 STANDARDS FOR WORKMANSHIP AND GOOD PRACTICE
20 - 5.2.1 Materials
20 - 5.2.2 Finish
20 - 5.2.3 Connection of services
20 - 5.3 LOCATION AND ACCESS
20 - 5.3.1 Building safety
20 - 5.3.2 Building structures
20 - 5.3.3 Safety and convenience
20 - 5.3.4 Combustible materials
20 - 5.3.5 Clearance for explosion relief
20 - 5.3.6 Explosion relief protection
20 - 5.3.7 Appliance security
21 - 5.3.8 Gas vent discharge
21 - 5.3.9 Foundations, supports
21 - 5.3.10 Lighting
21 - 5.4 FRESH AIR SUPPLY
21 - 5.4.1 Air supply
21 - 5.4.2 Air entries
21 - 5.4.3 Fan failure
21 - 5.5 FUEL SUPPLY SYSTEM
21 - 5.5.1 Fuel shut-off
21 - 5.5.2 Gas supply system
21 - 5.5.3 Oil fuel supply system
22 - 5.5.4 Solid fuel systems
22 - 5.6 COMMISSIONING
22 - 5.6.1 Commissioning agent
22 - 5.6.2 Information
22 - 5.6.3 Data and reports
23 - SECTION 6. FLUES (CHIMNEYS), EXHAUST
23 - 6.1 GENERAL
23 - 6.1.1 Removal of products of combustion
23 - 6.1.2 Provision of exhaust systems
23 - 6.1.3 Flues separate from exhausts
23 - 6.1.4 Common exhaust systems
23 - 6.1.5 Temperature hazards and comfort
23 - 6.1.6 Terminals for flues and exhaust ducts
23 - 6.2 FLUE DESIGN AND CONSTRUCTION
23 - 6.2.1 Construction
23 - 6.2.2 Performance
23 - 6.2.3 Common flues
24 - 6.2.4 Power flues
24 - 6.3 FLUE SUPPORTS
24 - 6.3.1 Direct-mounted flues
24 - 6.3.2 Free-standing flues
24 - 6.3.3 Guys, stays, and supports
24 - 6.4 EARTHING
24 - 6.5 FLUE DAMPERS
24 - 6.5.1 Damper/fuel interlock
24 - 6.5.2 Damper settings
24 - 6.6 DUCTS
24 - 6.6.1 Construction
24 - 6.6.2 Joints
24 - 6.6.3 Cleaning
24 - 6.6.4 Condensation provisions
24 - 6.6.5 Dampers
25 - APPENDIX A - OPERATING DATA, SPECIAL PURPOSE OVENS
26 - APPENDIX B - REGULAR TESTING OF SAFETY DEVICES AND PROCEDURES
26 - B1 REGULAR TESTING
26 - B2 PERSONNEL, ORGANIZATION.
26 - B3 GENERAL OUTLINE OF PROCEDURES
26 - B4 TYPICAL TESTING SCHEDULES
29 - APPENDIX C - TYPICAL IGNITION PROCEDURES
31 - APPENDIX D - CRITICAL ENERGY AND CRITICAL TIME
31 - D1 INTRODUCTION
32 - D2 SYMBOLS
33 - D3 CALCULATING THE CRITICAL TIME, CASE A
33 - D4 DERIVATION OF FORMULAS, CASE A
33 - D5 CALCULATING THE CRITICAL TIME, CASE B
33 - D6 DERIVATION OF FORMULA, CASE B
35 - APPENDIX E - RELIEF OF EXPLOSIONS
35 - E1 INTRODUCTION
36 - E2 OUTLINE OF DESIGN PROCEDURE
36 - E3 SYMBOLS
37 - E4 DETERMINATION OF MAXIMUM ALLOWABLE PRESSURE
37 - E4.1 Objective
37 - E4.2 Determination of strength
37 - E5 DETERMINATION OF RELIEF VENT AREA
38 - E6 DETERMINATION OF THE OPENING CHARACTERISTICS OF THE RELIEF VENT CLOSURE
38 - E6.1 Introduction
38 - E6.2 Mass-gravity closure
39 - E6.3 Hinged panels
39 - E6.4 Closure that bursts to relieve pressure
39 - E6.5 Spring-loaded panels
39 - E6.6 Panels held in place by magnets or spring catches
39 - E7 LOCATION OF RELIEF VENTS ON APPLIANCES
39 - REFERENCES
41 - APPENDIX F - DILUTION
41 - F1 INTRODUCTION
41 - F2 CALCULATION OF DILUTION AIRFLOW RATE
41 - F3 DETERMINATION OF V
41 - F4 DETERMINATION OF A
42 - F5 DETERMINATION OF VA
42 - F5.1 General
42 - F5.2 Calculation when either V or A is unknown
42 - F5.3 Calculation for mixed solvents
42 - F6 DETERMINATION OF C
42 - F7 DETERMINATION OF Q
42 - F7.1 Continuous process oven
42 - F7.2 Batch process ovens
43 - F8 DETERMINATION OF F
43 - F9 EXAMPLES OF CALCULATIONS
43 - F9.1 Continuous oven
43 - F9.2 Batch oven, below 120°C
43 - F9.3 Batch oven, above 120°C
45 - APPENDIX G - CHARACTERISTICS DATA
50 - APPENDIX H - MODEL COMMISSIONING PROCEDURE
50 - H1 SCOPE
50 - H2 STAGE 1: PRELIMINARY INSPECTION
50 - H3 STAGE 2: ACTIVATION-RUN WITHOUT FUEL
50 - H4 STAGE 3: ACTIVATION-RUN WITH FUEL
51 - H5 STAGE 4: OPERATION
51 - H6 STAGE 5: COMPLETION
52 - ANNEX - LIST OF REFERENCED DOCUMENTS

Gives principles for the design, construction and operation of industrial appliances that are heated by the combustion of a fuel, i.e. ovens, furnaces, boilers, dryers and the like. It deals with the safety of the fuel combustion process, and with safety in relation to combustible vapours, dusts, etc. that may occur or be generated within an appliance. Methods of calculating critical appliance characteristics, explosion relief areas, and air dilution volumes are given.

Committee
AG-011
DocumentType
Standard
ISBN
0 7262 1641 0
Pages
44
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This standard sets out the safety principles relating to the design, installation, and operation of industrial appliances that involve the combustion of gas or oil, or other fuel in air suspension, or the generation of combustible vapours in such appliances.NOTE: Although the rules for combustion safety given in this standard are applicable in principle to very high energy release appliances such as large land boilers for electricity generation and for solid fuel and pulverized coal firing, it should be recognized that appliances of such a size present unique problems, often requiring comparatively sophisticated control systems. Each such case should be studied individually and its safety evaluated in relation to its own particular conditions.

AS 4554-2005 Gas laundry dryers (Reconfirmed 2016)
AS/NZS 1596:2002 The storage and handling of LP Gas
AS/NZS 4114.1:2003 Spray painting booths, designated spray painting areas and paint mixing rooms Design, construction and testing
AS 3873-1995 Pressure equipment - Operation and maintenance
AS 4563-2003 (AG 300) Commercial catering gas equipment
AS 1470-1986 Health and safety at work - Principles and practices
AS 2593-2004 Boilers - Safety management and supervision systems (Reconfirmed 2016)
AS 3892-2001 Pressure equipment - Installation (Reconfirmed 2016)
AS 3653-1993 Boilers - Safety, management, combustion and other ancillary equipment
AS/NZS 2243.10:2004 Safety in laboratories Storage of chemicals
AS 1681-2002 Safety requirements for electrically heated Type 1 ovens in which flammable volatiles occur (Reconfirmed 2013)
AS 4563-2004 Commercial catering gas equipment (Reconfirmed 2016)
AS 3814-2005 Industrial and commercial gas-fired appliances
AS/NZS 4114(INT):1993 Electrical equipment for explosive atmospheres - Spray painting booths - Design, construction, installation and maintenance
AS 4558-2011 Decorative gas log and other fuel effect appliances
AS 2593-1995 Boilers - Unattended and limited attendance
AS 2809.5-2001 Road tank vehicles for dangerous goods Tankers for bitumen-based products
AS 4565-2004 Radiant gas heaters for outdoor and non-residential indoor use (Reconfirmed 2017)
AS 4041-2006 Pressure piping (Reconfirmed 2016)
AS 4554-2002 (AG 104) Gas laundry dryers
AS 2661-1983 Vapour degreasing plant - Design, installation and operation - Safety requirements
AS 4556-2011 Indirect gas-fired ducted air heaters
AS 4041-1992 Pressure piping
AS 2243.6-1990 Safety in laboratories - Mechanical aspects
AS 3814-2002 (AG 501) Industrial and commercial gas-fired appliances
AS/NZS 1596:1997 Storage and handling of LP Gas
AS 3873-2001 Pressure equipment - Operation and maintenance
AS/NZS 4114.1:1995 Spray painting booths - Design, construction and testing
AS 1853-1983 Automatic oil and gas burners - Mechanical draught
AS 1691-1985 Domestic oil-fired appliances - Installation
AS 2593-2001 Boilers - Unattended and limited attendance
AS 4551-2008 Domestic gas cooking appliances
HB 13-2007 Electrical equipment for hazardous areas
AS 4643-2007 Overhead radiant tube gas heaters
AS 2714-1993 The storage and handling of hazardous chemical materials - Class 5.2 substances (organic peroxides)
AS 5263.0-2013 Gas appliances General requirements
AS 3814-1998 Code for Industrial and Commercial Gas Fired Appliances
HB 13-2000 Electrical equipment for hazardous areas
AS 4557-2004 Domestic outdoor gas barbecues
AS 4552-2005 Gas fired water heaters for hot water supply and/or central heating
AS 2243.10-1993 Safety in laboratories - Storage of chemicals
AS 4560-2004 Gas pool heaters (Reconfirmed 2016)
AS 3892-1995 Pressure equipment - Installation
AS 3814-2009 Industrial and commercial gas-fired appliances

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.