AS 1025.1-1984
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
High-voltage a.c. switchgear and controlgear - Switches and switch-disconnectors - For rated voltages above 1 kV and less than 52 kV
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
06-30-2017
English
01-01-1984
Specifies requirements for a.c. switches and switch-disconnectors designed for indoor and outdoor installation for rated voltages above 1 kV and less than 52 kV and power frequencies up to and including 60 Hz. It is intended to be read in conjunction with AS 2650 and covers service conditions, definitions, ratings, design and construction requirements, type and routine tests, transport, erection, maintenance and quality control during manufacture.
Committee |
EL-007
|
DocumentType |
Standard
|
ISBN |
0 7262 3484 2
|
Pages |
16
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This standard specifies requirements for a.c. switches and switch-disconnectors designed for indoor and outdoor installation for rated voltages above 1 kV and less than 52 kV and power frequencies up to and including 60 Hz.This standard also applies to the operating devices of these switches and to their auxiliary equipment.NOTES:1. For a.c. switches and switch disconnectors having rated voltages of 52 kV and above, prior to the issue of Part 2 of this standard, reference should be made to IEC 265-2, in course of preparation. In the meantime the appropriate provisions of IEC 265 apply to such switches and switch disconnectors.2. The term 'switch' applies to all kinds of switches and switch disconnectors within the scope of this standard. This standard does not require all switches to provide dis- connection (isolating) characteristics across open contacts. Where such characteristics are required, in conformity with IEC terminology, it is necessary to specify switch disconnectors.3. Earthing switches forming an integral part of a switch are covered by AS 1306. If the earthing switch has a rated short-circuit making current the making tests need to be made according to the requirements in this standard.4. High voltage alternating current contactors, high voltage fuse switch combinations and high voltage motor starters are covered by AS 1864, AS 2024 and AS 2232 respectively.
Under Revision see DR 01059
AS 2067-1984 | Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV |
AS 2989-1992 | Electrical equipment for coal mines - Specific requirements for high voltage circuit-breakers and disconnectors |
AS 2024-1991 | High voltage a.c. switchgear and controlgear - Switch-fuse combinations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.