ANSI S3.55-1 : 2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 1: EAR SIMULATOR FOR THE MEASUREMENT OF SUPRA-AURAL AND CIRCUMAURAL EARPHONES
Hardcopy , PDF
07-13-2019
English
01-01-2014
1 Scope
2 Normative references
3 Terms and definitions
4 Construction
5 Coupling of earphone to ear simulator
6 Calibration
7 Maximum permitted expanded uncertainty
of measurements
Annex A (informative) - Lumped parameter electrical
network analogue of the ear simulator
Annex B (informative) - Example of one specific design
of ear simulator
Annex C (informative) - Measurement method for the
determination of the acoustical transfer
impedance of the ear simulator
Bibliography
Defines an ear simulator for the measurement of supra-aural and circumaural earphones (used for example in audiometry and telephonometry) applied to the ear without acoustical leakage, in the frequency range from 20 Hz to 10 kHz.
Committee |
S3
|
DevelopmentNote |
Also numbered as IEC 60318-1. (03/2014)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
Acoustical Society of America
|
Status |
Superseded
|
SupersededBy |
ANSI/ASA S3.20 : 2015 | American National Standard Bioacoustical Terminology |
ANSI/ASA S3.7 : 2016 | METHOD FOR MEASUREMENT AND CALIBRATION OF EARPHONES |
IEC 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
ISO 389-8:2004 | Acoustics — Reference zero for the calibration of audiometric equipment — Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones |
ISO 389-5:2006 | Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz |
ISO 389-1:1998 | Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones |
IEC 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
IEC 61094-6:2004 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.