AAMI ISO 8638 : 2010 : R2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - EXTRACORPOREAL BLOOD CIRCUIT FOR HEMODIALYZERS, HEMODIAFILTERS AND HEMOFILTERS
11-23-2015
11-19-2015
Glossary of equivalent standards
Committee representation
Background of ANSI/AAMI adoption of ISO 8638:2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
6 Labeling
Bibliography
Describes requirements for the single-use extracorporeal blood circuit and (integral and nonintegral) transducer protectors which are intended for use in hemodialysis, hemodiafiltration and hemofiltration.
Committee |
ISO/TC 150
|
DevelopmentNote |
Supersedes AAMI RD17. (02/2011)
|
DocumentType |
Standard
|
ProductNote |
Reconfirmed 2015
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 8638:2010 | Identical |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
ISO 15223-2:2010 | Medical devices — Symbols to be used with medical device labels, labelling, and information to be supplied — Part 2: Symbol development, selection and validation |
ISO 8637:2010 | Cardiovascular implants and extracorporeal systems Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators |
ISO/TS 17665-2:2009 | Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1 |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
ISO 11135-1:2007 | Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 10993-11:2017 | Biological evaluation of medical devices — Part 11: Tests for systemic toxicity |
ISO 11137-3:2017 | Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 11137-2:2013 | Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose |
ISO 7864:2016 | Sterile hypodermic needles for single use — Requirements and test methods |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO/TS 11135-2:2008 | Sterilization of health care products Ethylene oxide Part 2: Guidance on the application of ISO 11135-1 |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
ISO 594-2:1998 | Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.